Junghun Lee

Junghun Lee

Auto-generated profile, based on publicly available information

Junghun Lee

Energy ICT∙ESS Laboratory, Korea Institute of Energy Research, Daejeon 34101, Korea

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in Renewable and Sustainable Energy Reviews
Verified
Journal Article
Closed access
JLJunghun Lee
Junghun Lee
JKJeonggook Kim
Jeonggook Kim
Doosam SongDoosam Song
Doosam Song
JKJonghun Kim
Jonghun Kim
CJCheolyong Jang
Cheolyong Jang

1 February 2018 in Energy
Verified
Journal Article
Closed access
JLJunghun Lee
Junghun Lee
SYSeunghwan Yoo
Seunghwan Yoo
JKJonghun Kim
Jonghun Kim
Doosam SongDoosam Song
Doosam Song
HJHakgeun Jeong
Hakgeun Jeong

19 July 2018 in Energies
Verified
Journal Article
Open access
PDF file
SKSeo-Hoon Kim
Seo-Hoon Kim
JLJung-Hun Lee
Jung-Hun Lee
JKJonghun Kim
Jonghun Kim
SYSeung-Hwan Yoo
Seung-Hwan Yoo
Hakgeun JeongHakgeun Jeong
Hakgeun Jeong
This paper reports on a feasibility study conducted to improve the in situ measurement accuracy of the air-surface temperature ratio (ASTR) method. The measured relative error rate was analyzed using the ISO 6946 [7.69 W/(m2·K)] and Korea Energy Saving Design Standard [9.09 W/(m2·K)] indoor total surface heat transfer coefficients. The relative error rate was analyzed according to fluctuations in outdoor temperature data. The relative error rate obtained using the ISO 6946 standard was analyzed about 6.3% and that obtained using the Korea Energy Saving Design Standard was about 9.5%. The relative error rate measured for outdoor temperature fluctuations of less than 1 K was about 4.62% and that for temperatures greater than 1 K was about 14.31%. The study results confirmed the cause of the error in the measurement of the ASTR. It was also found that the accuracy of the latter can be improved when the ISO 6946 indoor total surface heat transfer coefficient is applied and when outdoor temperature fluctuations less than 1 K are sampled and analyzed.

7 October 2015 in Energies
Verified
Journal Article
Open access
PDF file
JKJeong-Gook Kim
Jeong-Gook Kim
JLJunghun Lee
Junghun Lee
BAByung-Lip Ahn
Byung-Lip Ahn
HSHwayeon Shin
Hwayeon Shin
SYSeunghwan Yoo
Seunghwan Yoo
JKJonghun Kim
Jonghun Kim
Temporary housing must be developed to support the long-term residence needs of disaster victims. The present study assesses a temporary housing unit, the so-called Mobile Energy Shelter House (MeSH), incorporating the “Korean Dwelling Insulation Standard” in order to reduce energy usage for cooling and heating. To assess energy performance, the characteristics of the indoor thermal environment were measured during the winter and summer seasons. In summer, at maximum insolation, the outdoor temperature was 37.6 °C and the indoor temperature of the MeSH ranged from 18 to 24 °C when the cooling system was not used. Conversely, during winter, the average outdoor temperature was −11.3 °C and the indoor temperature ranged from 16.09 to 20.63 °C when a temperature-controlled floor-heating was installed. Furthermore, the Predicted Mean Vote (PMV) was adopted to determine whether the ISO 7730 comfort criterion (i.e., PMV range from −0.5 to +0.5) was achieved. Based on the calculations presented here, PMV in summer ranged from −1.21 to +1.07 and that in winter ranged from −0.08 to −0.85, suggesting that the thermal environment is not always comfortable for occupants in either summer or winter. Nevertheless, the ISO comfort criterion can be achieved through varying air velocity in summer and changing clothing characteristics in winter. A comparison between yearly energy demand of existing characteristic temporary housing (Shelter House) and the MeSH modules used in this study was performed. The simulation results show a 60% difference in energy demand between MeSH and existing temporary housing shelter houses.

1 July 2018 in Applied Energy
Verified
Journal Article
Closed access
JLJunghun Lee
Junghun Lee
SKSeohoon Kim
Seohoon Kim
JKJonghun Kim
Jonghun Kim
Doosam SongDoosam Song
Doosam Song
HJHakgeun Jeong
Hakgeun Jeong

19 August 2015 in Building Services Engineering Research & Technology
Verified
Journal Article
Closed access
JKJeonggook Kim
Jeonggook Kim
JLJunghun Lee
Junghun Lee
JKJonghun Kim
Jonghun Kim
CJCheolyong Jang
Cheolyong Jang
HJHakgeun Jeong
Hakgeun Jeong
Doosam SongDoosam Song
Doosam Song
The temperature difference ratio is used to measure the thermal performance of a building envelope. Calculation of temperature difference ratio requires temperature differences between indoor and outdoor environments and wall surface temperatures, obtained here using an infrared camera. This approach performs well when the temperature differential between indoor and outdoor environments is greater than 10℃ and when wind speed is less than 3.0 m/s. We identify periods suitable for accurate evaluation of thermal insulation performance with an infrared camera, based on eight cities in Korea. The number of measureable hours ranges between 3183 and 1317 annually. Optimum periods for measurement are between November and March, specifically between 01:00 and 09:00 h. Measurements obtained during these periods can therefore be regarded as relatively accurate. Practical application: A thermal imaging camera provides an easy method for checking the insulation performance and construction conditions of a building. Conventionally, this would be checked experimentally, but thermal imaging allows easy visualization of conditions.