Quemada  Mayoral

Dr. Quemada Mayoral

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 May 2021 in Remote Sensing
Verified
Journal Article
Open access
PDF file
QMQuemada Mayoral
Quemada Mayoral
José Pérez-EscuderoJosé Pérez-Escudero
José Pérez-Escudero
RGRamón Gonzalo
Ramón Gonzalo
Iñigo EderraIñigo Ederra
Iñigo Ederra
LSLuis G. Santesteban
Luis G. Santesteban
JIJuan Carlos Iriarte
Juan Carlos Iriarte
This paper reviews the different remote sensing techniques found in the literature to monitor plant water status, allowing farmers to control the irrigation management and to avoid unnecessary periods of water shortage and a needless waste of valuable water. The scope of this paper covers a broad range of 77 references published between the years 1981 and 2021 and collected from different search web sites, especially Scopus. Among them, 74 references are research papers and the remaining three are review papers. The different collected approaches have been categorized according to the part of the plant subjected to measurement, that is, soil (12.2%), canopy (33.8%), leaves (35.1%) or trunk (18.9%). In addition to a brief summary of each study, the main monitoring technologies have been analyzed in this review. Concerning the presentation of the data, different results have been obtained. According to the year of publication, the number of published papers has increased exponentially over time, mainly due to the technological development over the last decades. The most common sensor is the radiometer, which is employed in 15 papers (20.3%), followed by continuous-wave (CW) spectroscopy (12.2%), camera (10.8%) and THz time-domain spectroscopy (TDS) (10.8%). Excluding two studies, the minimum coefficient of determination (R2) obtained in the references of this review is 0.64. This indicates the high degree of correlation between the estimated and measured data for the different technologies and monitoring methods. The five most frequent water indicators of this study are: normalized difference vegetation index (NDVI) (12.2%), backscattering coefficients (10.8%), spectral reflectance (8.1%), reflection coefficient (8.1%) and dielectric constant (8.1%).

1 January 2016 in Journal of Computational and Applied Mathematics
Verified
Journal Article
Closed access
JSJuan Antonio Sicilia
Juan Antonio Sicilia
QMQuemada Mayoral
Quemada Mayoral
BRBeatriz Royo
Beatriz Royo
DEDavid Escuín
David Escuín

1 January 2016 in Journal of Computational and Applied Mathematics
Verified
Journal Article
Closed access
Alicia CorderoAlicia Cordero
Alicia Cordero
Ángel Alberto MagreñánÁngel Alberto Magreñán
Ángel Alberto Magreñán
QMQuemada Mayoral
Quemada Mayoral
Juan R. TorregrosaJuan R. Torregrosa
Juan R. Torregrosa

11 October 2019 in Sensors
Verified
Journal Article
Open access
PDF file
IJIrati Jáuregui-López
Irati Jáuregui-López
PUPablo Rodriguez Ulibarri
Pablo Rodriguez Ulibarri
SKSergei A. Kuznetsov
Sergei A. Kuznetsov
QMQuemada Mayoral
Quemada Mayoral
Miguel BerueteMiguel Beruete
Miguel Beruete
The use of metasurfaces operating in the terahertz regime as biosensor devices has attracted increased interest in recent years due to their enhanced sensitivity and more accurate detection capability. Typical designs are based on the replica of relatively simple unit cells, usually called metaatoms. In a previous paper, we proposed a new paradigm for ultrasensitive thin-film sensors based on complex unit cells, called generically metageometries or labyrinth metasurfaces. Here, we extend this concept towards biosensing, evaluating the performance of the labyrinth as a fungi detector. The sensing capabilities are numerically evaluated and a comparison with previous works in this field is performed, showing that metageometries improve the performance compared to metaatoms both in sensitivity and figure of merit, by a factor of more than four. In particular, we find that it is able to detect five fungi elements scattered on the unit cell, equivalent to a concentration of only 0.004/µm2.

19 March 2019 in IEEE Transactions on Geoscience and Remote Sensing
Verified
Journal Article
Closed access
QMQuemada Mayoral
Quemada Mayoral
CGCebrian Garcia Gonzalez
Cebrian Garcia Gonzalez
JGJuan Carlos Iriarte Galarregui
Juan Carlos Iriarte Galarregui
DMDiana Marin
Diana Marin
DGDiego Gaston
Diego Gaston
Iñigo EderraIñigo Ederra
Iñigo Ederra
This paper presents the real-time monitoring of a grapevine's water content that flows up through the xylem tissue by means of a frequency-modulated continuous-wave radar. The application of an optimization process, based on the super-resolution multiple signal classification algorithm, has enabled the reduction of the bandwidth required to discern the xylem water content and, thus, the operating frequency, achieving a depth resolution of at least 3 mm. This design advantage has resulted in a significant step forward toward a real life application, allowing the use of fully-integrated off-the-shelf components in order to implement a completely portable low-power cost-effective radar at 23.1 GHz with a 3.4-GHz bandwidth. The sensor performance has been evaluated by means of three different experiments: irrigation cycles, day/night cycles, and comparison between irrigation cycles at different temperatures. From the experimental results, it is possible to assert that the contactless sensor presented in this paper is very sensitive to changes in the plant's water content, differentiating between daytime and nighttime. In addition, it has been proven that temperature has a noticeable influence over the evapotranspiration, observing negative drying slopes of 5.62 and 6.28 mV/cycle at 23 °C and 26 °C, respectively.

10 December 2020 in Electronics
Verified
Journal Article
Open access
PDF file
José Pérez-EscuderoJosé Pérez-Escudero
José Pérez-Escudero
QMQuemada Mayoral
Quemada Mayoral
RGRamón Gonzalo
Ramón Gonzalo
Iñigo EderraIñigo Ederra
Iñigo Ederra
In this paper the design and experimental characterization of a combined doubler-subharmonic mixer based on Schottky diodes which uses a 75 GHz MMIC based local oscillator is presented. This solution integrates in the same substrate the doubler and the mixer, which share the same metallic packaging with the local oscillator. The prototype has been fabricated and measured. For characterization, the Y-Factor technique has been used and the prototype yields a best conversion loss and equivalent noise temperature of 11 dB and 1976 K, respectively, at 305 GHz. This performance is close to the state of the art, and shows the potential of this approach, which allows a significant reduction in terms of size and volume.