Arthrofibrosis after total knee arthroplasty represents a considerable burden for the patient and a therapeutic challenge for the practitioner. One possible cause discussed in the literature is a low-grade infection. This hypothesis should be examined within the scope of this retrospective study. Nineteen patients with clinical symptoms of arthrofibrosis after primary total knee arthroplasty were examined between January, 1999 and January, 2012. Incorrect positioning was radiologically ruled out. All patients were examined clinically (score of Freeman as well as Blauth and Jäger), radiologically (component and leg alignment, patella height according to Insall and Salvati), microbiologically (culture-based procedures), molecular biologically (PCR) and histologically in the course of an open revision of the prosthesis. According to the score of Freeman et al. (1977), a highly significant improvement in pain (p = 0.007) and in the overall score (p = 0.003) was shown. The knee joint mobility did not change significantly (p = 0.795). PCR was negative in 17 patients. One patient showed a PCR-positive result of the synovial membrane for Corynebacterium spp., while Staphylococcus warneri was detected in the culture. Another patient had a positive result of synovia PCR for Enterococcus cecorum as well as Corynebacterium spp. However, this culture was sterile. In 16 patient samples, no bacterial growth was detectable. Two samples were not evaluable. The main histopathological findings were synovialitis and fibrosis. The hypothesis of low-grade-infection-induced arthrofibrosis after total knee arthroplasty could not be confirmed in this study. However, based on this small study population the conclusion needs to be confirmed by new and larger studies, ideally prospectively designed including a control group.
There are multiple attempts to decrease costs in the healthcare system while maintaining a high treatment quality. Digital therapies receive increasing attention in clinical practice, mainly relating to home-based exercises supported by mobile devices, eventually in combination with wearable sensors. The aim of this study was to determine if patients following total hip arthroplasty (THA) could benefit from gait training on crutches conducted by a mobile robot in a clinical setting. Method: This clinical trial was conducted with 30 patients following total hip arthroplasty. Fifteen patients received the conventional physiotherapy program in the clinic (including 5 min of gait training supported by a physiotherapist). The intervention group of 15 patients passed the same standard physiotherapy program, but the 5-min gait training supported by a physiotherapist was replaced by 2 × 5 min of gait training conducted by the robot. Length of stay of the patients was set to five days. Biomechanical gait parameters of the patients were assessed pre-surgery and upon patient discharge. Results: While before surgery no significant difference in gait parameters was existent, patients from the intervention group showed a significant higher absolute walking speed (0.83 vs. 0.65 m/s, p = 0.029), higher relative walking speed (0.2 vs. 0.16 m/s, p = 0.043) or shorter relative cycle time (3.35 vs. 3.68 s, p = 0.041) than the patients from the control group. Conclusion: The significant higher walking speed of patients indicates that such robot-based gait training on crutches may shorten length of stay (LOS) in acute clinics. However, the number of patients involved was rather small, thus calling for further studies.
Effects of hydroxyapatite (HA) particles with bone morphogenetic BMP-2 or GDF-5 were compared in sheep lumbar osteopenia; in vitro release in phosphate-buffered saline (PBS) or sheep serum was assessed by ELISA. Lumbar (L) vertebral bone defects (Ø 3.5 mm) were generated in aged, osteopenic female sheep (n = 72; 9.00 ± 0.11 years; mean ± SEM). Treatment was: (a) HA particles (2.5 mg; L5); or (b) particles coated with BMP-2 (1 µg; 10 µg) or GDF-5 (5 µg; 50 µg; L4; all groups n = 6). Untouched vertebrae (L3) served as controls. Three and nine months post-therapy, bone formation was assessed by osteodensitometry, histomorphometry, and biomechanical testing. Cumulative 14-day BMP release was high in serum (76–100%), but max. 1.4% in PBS. In vivo induction of bone formation by HA particles with either growth factor was shown by: (i) significantly increased bone volume, trabecular and cortical thickness (overall increase HA + BMP vs. control close to the injection channel 71%, 110%, and 37%, respectively); (ii) partial significant effects for bone mineral density, bone formation, and compressive strength (increase 17%; 9 months; GDF-5). Treatment effects were not dose-dependent. Combined HA and BMPs (single low-dose) highly augment long-term bone formation and biomechanical stabilization in sheep lumbar osteopenia. Thus, carrier-bound BMP doses 20,000-fold to 1000-fold lower than previously applied appear suitable for spinal fusion/bone regeneration and improved treatment safety.