In this work, the potential of an innovative "edgeless" silicon diode was evaluated as a response to the still unmet need of a reliable tool for plan dosimetry verification of very high dose, non-coplanar, patient-specific radiosurgery treatments. In order to prove the effectiveness of the proposed technology, we focused on radiosurgical treatments for functional disease like tremor or pain. The edgeless diodes response has been validated with respect to clinical practice standard detectors by reproducing the reference dosimetry data adopted for the Treatment Planning System. In order to evaluate the potential for radiosurgery patient-specific treatment plan verification, the anthropomorphic phantom Alderson RANDO has been adopted along with three edgeless sensors, one placed in the centre of the Planning Target Volume, one superiorly and one inferiorly. The reference dosimetry data obtained from the edgeless detectors are within 2.6% for output factor, off-axis ratio and well within 2% for tissue phantom ratio when compared to PTW 60,018 diode. The edgeless detectors measure a dose discrepancy of approximately 3.6% from the mean value calculated by the TPS. Larger discrepancies are obtained in very steep gradient dose regions when the sensors are placed outside the PTV. The angular independent edgeless diode is proposed as an innovative dosimeter for patient quality assurance of brain functional disorders and other radiosurgery treatments. The comparison of the diode measurements with TPS calculations confirms that edgeless diodes are suitable candidates for patient-specific dosimetric verification in very high dose ranges delivered by non-isocentric stereotactic radiosurgery modalities.
Background: Hypo-fractionation can be an effective strategy to lower costs and save time, increasing patient access to advanced radiation therapy. To demonstrate this potential in practice within the context of temporal evolution, a twenty-year analysis of a representative radiation therapy facility from 2003 to 2022 was conducted. This analysis utilized comprehensive data to quantitatively evaluate the connections between advanced clinical protocols and technological improvements. The findings provide valuable insights to the management team, helping them ensure the delivery of high-quality treatments in a sustainable manner. Methods: Several parameters related to treatment technique, patient positioning, dose prescription, fractionation, equipment technology content, machine workload and throughput, therapy times and patients access counts were extracted from departmental database and analyzed on a yearly basis by means of linear regression. Results: Patients increased by 121 ± 6 new per year (NPY). Since 2010, the incidence of hypo-fractionation protocols grew thanks to increasing Linac technology. In seven years, both the average number of fractions and daily machine workload decreased by −0.84 ± 0.12 fractions/year and −1.61 ± 0.35 patients/year, respectively. The implementation of advanced dose delivery techniques, image guidance and high dose rate beams for high fraction doses, currently systematically used, has increased the complexity and reduced daily treatment throughput since 2010 from 40 to 32 patients per 8 h work shift (WS8). Thanks to hypo-fractionation, such an efficiency drop did not affect NPY, estimating 693 ± 28 NPY/WS8, regardless of the evaluation time. Each newly installed machine was shown to add 540 NPY, while absorbing 0.78 ± 0.04 WS8. The COVID-19 pandemic brought an overall reduction of 3.7% of patients and a reduction of 0.8 fractions/patient, to mitigate patient crowding in the department. Conclusions: The evolution of therapy protocols towards hypo-fractionation was supported by the use of proper technology. The characteristics of this process were quantified considering time progression and organizational aspects. This strategy optimized resources while enabling broader access to advanced radiation therapy. To truly value the benefit of hypo-fractionation, a reimbursement policy should focus on the patient rather than individual treatment fractionation.
To quantitatively evaluate the possible advantages of quantifying and differentiating various soft tissues using virtual monochromatic images (VMI) derived from different dual-energy computed tomography (DECT) technologies. This study involved four DECT scanners with different technologies. CIRS phantom images were acquired in single-energy (SECT) and DECT modes with each scanner. The analysis focused on five equivalent soft-tissue inserts: adipose, breast, liver, muscle, and bone (200 mg). The signal-to-noise ratio (SNR) was calculated for each equivalent soft-tissue insert. Finally, the contrasts of tissue pairs between DECT and SECT images were compared using Wilcoxon signed-rank tests adjusted for multiple comparisons. Average CT numbers and noise showed a significant difference pattern between DECT with respect to SECT for each CT scanner. Generally, energy levels of 70 keV or higher led to improved SNR in VMI for most of the equivalent soft-tissue inserts. However, energy levels of 40–50 keV showed significantly higher contrasts in most of the equivalent soft-tissue insert pairs. DECT images at low energies, especially at 40–50 keV, outperform SECT images in discriminating soft tissues across all four DECT technologies. The combined use of DECT images reconstructed at different energy levels provides a more comprehensive set of information for diagnostic and/or radiotherapy evaluation compared to SECT. Some differences between scanners are evident, depending on the DECT acquisition technique and reconstruction method.
Patient-specific quality assurance (PSQA) procedures ensure the safe delivery of volumetric modulated arc therapy (VMAT) plans. PSQA requires extensive time and resources and may cause treatment delays if replanning is needed due to failures. Recently, our group developed a machine learning (ML) model predicting gamma passing rate (GPR) for VMAT arcs. This study explores automatable replanning strategies for plans identified at risk of failure, aiming to improve deliverability while maintaining dosimetric quality. Between 2022 and 2023, our ML model analyzed 1252 VMAT plans. Ten patients having a predicted GPR (pGPR) <95% were selected. Replanning strategies consisted of limiting monitor units (MUlimit) and employing the aperture shape controller (ASC) tool. Re-optimized plans were compared with the originals in terms of dose volume constraints (DVCs) for the target and organs-at-risk (OARs), and deliverability using the modulation complexity score (MCS), pGPR, and measured GPR (mGPR). Forty-five re-optimizations were performed. Replanning led to an increase in DVCs for OARs and a reduction for the target. Complexity decreased, reflected by the increase in the MCS from 0.17 to 0.21 (MUlimit) and 0.20 (ASC). The deliverability improved, with the pGPR increasing from 93.3% to 94.4% (MUlimit) and 95.1% (ASC), and the mGPR from 99.3% to 99.7% (MUlimit) and 99.8% (ASC). Limiting the MUs or utilizing the ASC reduced the complexity of plans and improved the GPR without compromising the dosimetric quality. These strategies can be used to automate replanning procedures, reduce the workload related to PSQA, and improve patient safety.
Background: Radiotherapy for thymoma is delivered post-operatively in selected cases. Given the particular location of the thymic bed and the excellent prognosis, late cardiac toxicities may be an issue. The purpose of this retrospective dosimetric study is to investigate whether intensity-modulated proton beam therapy (IMPT) compared to photon therapy could better spare cardiac substructures, given prespecified dose constraints. Methods: We retrospectively selected patients treated with adjuvant radiotherapy for thymoma in our institution. We manually contoured fourteen cardiac substructures (CSs), with the supervision of a team of cardioradiologists. The photon-based plans were re-optimized in adherence to the volumetric modulated arc therapy (VMAT) technique with specific dose constraints for the new contoured structures. The proton-based plans were optimized in adherence to intensity-modulated proton therapy (IMPT) using the beam spot scanning technique. Results: Twenty-nine patients treated with adjuvant radiotherapy with a prescribed dose of 50 Gy in 25 daily fractions for radically resected thymoma were selected. IMPT demonstrated better sparing of most cardiac substructures in terms of Dmax, Dmean and V5Gy. Finally, IMPT plans more easily achieved the proposed dose constraints. Conclusions: Cardiac substructures can be successfully spared with IMPT. Clinical studies are needed to establish a relationship between dose parameters and the development of cardiac events.