Sultan Fahad Alhujaili

Sultan Fahad Alhujaili

Auto-generated profile, based on publicly available information

Sultan Fahad Alhujaili

Radiation Sciences and Medical Imaging Department, College of Applied Medical Sciences, Jouf University

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2021 in Physica Medica
Verified
Journal Article
Open access
EMElena De Martin
Elena De Martin
SASultan Alhujaili
Sultan Alhujaili
MFMaria Luisa Fumagalli
Maria Luisa Fumagalli
FGfrancesco ghielmetti
francesco ghielmetti
MMMarcello Marchetti
Marcello Marchetti
MPMarco Petasecca
Marco Petasecca
In this work, the potential of an innovative "edgeless" silicon diode was evaluated as a response to the still unmet need of a reliable tool for plan dosimetry verification of very high dose, non-coplanar, patient-specific radiosurgery treatments. In order to prove the effectiveness of the proposed technology, we focused on radiosurgical treatments for functional disease like tremor or pain. The edgeless diodes response has been validated with respect to clinical practice standard detectors by reproducing the reference dosimetry data adopted for the Treatment Planning System. In order to evaluate the potential for radiosurgery patient-specific treatment plan verification, the anthropomorphic phantom Alderson RANDO has been adopted along with three edgeless sensors, one placed in the centre of the Planning Target Volume, one superiorly and one inferiorly. The reference dosimetry data obtained from the edgeless detectors are within 2.6% for output factor, off-axis ratio and well within 2% for tissue phantom ratio when compared to PTW 60,018 diode. The edgeless detectors measure a dose discrepancy of approximately 3.6% from the mean value calculated by the TPS. Larger discrepancies are obtained in very steep gradient dose regions when the sensors are placed outside the PTV. The angular independent edgeless diode is proposed as an innovative dosimeter for patient quality assurance of brain functional disorders and other radiosurgery treatments. The comparison of the diode measurements with TPS calculations confirms that edgeless diodes are suitable candidates for patient-specific dosimetric verification in very high dose ranges delivered by non-isocentric stereotactic radiosurgery modalities.

27 March 2019 in IEEE Transactions on Radiation and Plasma Medical Sciences
Verified
Journal Article
Closed access
SASultan F. Alhujaili
Sultan F. Alhujaili
JDJeremy A. Davis
Jeremy A. Davis
JDJustin Davies
Justin Davies
MLMichael Lerch
Michael Lerch
ARAnatoly B. Rosenfeld
Anatoly B. Rosenfeld
MPMarco Petasecca
Marco Petasecca
In this paper, the performance of an ‘edgeless’ device is evaluated for use as an angular independent detector for dosimetric quality assurance in radiotherapy. The ‘edgeless’ diodes were tested in terms of current-voltage (IV) and capacitance-voltage (CV) characteristics, charge collection efficiency and radiation hardness. A model of the ‘edgeless’ device was developed to simulate the distribution of the electric field for different geometries using TCAD. IV and CV characteristics of the diodes indicate the appropriate operational conditions and provide a means to assess the consistency/quality of the edgeless diode technology. TCAD model shows good agreement with experimental results demonstrating the accuracy of the model in simulating the behaviour of the edgeless diodes. The charge collection efficiency is evaluated for two of the edgeless configurations PP and NP. The angular dependence measurements of edgeless devices before and after 2 Mrad irradiation shows negligible effect of radiation damage on response as a function of the angle. The experimental data are supported by the results of the TCAD simulation study, which indicates negligible impact of radiation damage from a clinical use perspective. Both the experimental and simulated results derived from the radiation damage study show minimal degradation (within 4%) of the diodes sensitivity.

2 November 2024 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
AAAbdulaziz Alshabibi
Abdulaziz Alshabibi
MSMoayyad E. Suleiman
Moayyad E. Suleiman
SASultan F. Alhujaili
Sultan F. Alhujaili
SASalman Albeshan
Salman Albeshan
PBPatrick C. Brennan
Patrick C. Brennan

21 January 2025 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
SASultan Fahad Alhujaili
Sultan Fahad Alhujaili
ASA. Sulieman
A. Sulieman
ZAZiyad Awadh Alrowaili
Ziyad Awadh Alrowaili
AAAbdulaziz Saad A. Alshabibi
Abdulaziz Saad A. Alshabibi
FAFeras Alafer
Feras Alafer
MAMohamed Abuzaid
Mohamed Abuzaid

25 November 2025 in Journal of Radiation Research and Applied Sciences
Verified
Journal Article
Open access
SASultan Fahad Alhujaili
Sultan Fahad Alhujaili
ZAZiyad Alrowaili
Ziyad Alrowaili
AAAbdulaziz Saad Alshabibi
Abdulaziz Saad Alshabibi
FAFeras Alafer
Feras Alafer
RAReyan Alharbi
Reyan Alharbi
AAAbdullah Abuhaimed
Abdullah Abuhaimed

18 November 2025 in International Journal of Radiation Biology
Verified
Journal Article
Closed access
SASultan Fahad Alhujaili
Sultan Fahad Alhujaili
FAFeras Alafer
Feras Alafer
AAAbdulaziz Alshabibi
Abdulaziz Alshabibi
EAEmad Ali Alsherif
Emad Ali Alsherif
SKShereen Korany
Shereen Korany
Samy SelimSamy Selim
Samy Selim
Sprouting boosts bioactive compounds in Brassicaceae, including glucosinolates, amino acids, and anthocyanins. This study examined gamma radiation seed priming effects on growth, metabolism, and bioactive accumulation in Nasturtium officinale, Eruca sativa, and Raphanus raphanistrum sprouts. Seeds of the three species were primed with gamma radiation (0.1 kGy/h) and grown under controlled conditions. Biomass was measured; metabolic profiling quantified glucosinolates, amino acids, flavonoids, and anthocyanins. Enzymatic activities for glucosinolate and flavonoid biosynthesis were assessed. Antioxidant potential was assessed using FRAP and DPPH assays; antimicrobial activity was tested against Escherichia coli and Enterococcus faecalis. Microbial counts (APCs and Coliforms) were measured. Gamma radiation increased biomass by 48%, 36%, and 71% in N. officinale, E. sativa, and R. raphanistrum, respectively. Glucosinolates rose, especially glucoerucin (up to 227% in E. sativa) and glucoraphenin (up to 60%), linked to higher precursor amino acids (leucine, tryptophan, methionine), glutathione, and activities of glutathione S-transferase and sulfotransferase. Myrosinase activity increased, boosting sulforaphane. Flavonoids surged: quercetin (48 -191%), kaempferol (75 -172%), anthocyanins (42 -60%), with elevated PAL, CHS, 4CL, and C4H activities. Antioxidant and antimicrobial (40 -77%) potentials improved, though APCs and coliforms rose. Gamma radiation priming enhances growth, secondary metabolite accumulation, antioxidant potential, and antimicrobial activity in Brassicaceae sprouts. It offers a promising method to improve the nutritional and functional qualities of edible sprouts, aiding food safety and health.