M Amparo Díez-Ajenjo

Dr. M Amparo Díez-Ajenjo

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2011 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
AFAdelina Felipe
Adelina Felipe
JAJosé M. Artigas
José M. Artigas
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
PAPablo Alcocer
Pablo Alcocer
To analyze changes in the eye's refractive properties when a toric intraocular lens (IOL) rotates. Fundación Oftalmológica del Mediterráneo, Valencia, Spain. Experimental study. The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C(1) and C(2) whose axes form an angle a, is obtained by the addition of 2 vectors of values C(1) and C(2) forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part F(nes,) the ortho-astigmatism F(or), and oblique astigmatism F(ob). The residual cylinder was one third of the corneal astigmatism when a toric IOL rotated ±10 degrees when the cylinder values for the cornea (C(1)) and IOL (C(2)) were equal. Nevertheless, in most cases C(1) is greater than C(2); therefore, the residual astigmatism did not change noticeably with small rotations. The angle of rotation, b, which annuls the astigmatism correction, could be obtained from the following: cos(π + 2b) = -r/2, with r being the ratio between the IOL and cornea cylinders. The 2 methods gave equivalent results. When the IOL cylinder had a value different from that of the corneal astigmatism, a better choice would be a lower, rather than higher, cylinder value to reduce residual astigmatism. In general, toric IOL rotations less than 10 degrees changed the eye's refraction less than 0.50 diopter. Thus, small axis rotations are not an obstacle for satisfactory astigmatism correction with toric IOLs. No author has a financial or proprietary interest in any material or method mentioned.

25 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CBCeleste Briceno-Lopez
Celeste Briceno-Lopez
Neus Burguera-GiménezNeus Burguera-Giménez
Neus Burguera-Giménez
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
MLMaría Josefa Luque
María Josefa Luque
This systematic review investigates the prevalence and underlying causes of corneal edema following cataract surgery employing manual phacoemulsification. A comprehensive search encompassing databases such as PubMed, Embase, ProQuest, Cochrane Library, and Scopus was conducted, focusing on variables encompassing cataract surgery and corneal edema. Two independent reviewers systematically extracted pertinent data from 103 articles, consisting of 62 theoretical studies and 41 clinical trials. These studies delved into various aspects related to corneal edema after cataract surgery, including endothelial cell loss, pachymetry measurements, visual performance, surgical techniques, supplies, medications, and assessments of endothelial and epithelial barriers. This review, encompassing an extensive analysis of 3060 records, revealed significant correlations between corneal edema and endothelial cell loss during phacoemulsification surgery. Factors such as patient age, cataract grade, and mechanical stress were identified as contributors to endothelial cell loss. Furthermore, pachymetry and optical coherence tomography emerged as valuable diagnostic tools for assessing corneal edema. In conclusion, this systematic review underscores the link between corneal edema and endothelial cell loss in manual phacoemulsification cataract surgery. It highlights the relevance of factors like patient demographics and diagnostic modalities. However, further research is essential to unravel the complexities of refractive changes and the underlying mechanisms.

1 April 2010 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
AFAdelina Felipe
Adelina Felipe
FPFrancisco Pastor
Francisco Pastor
JAJosé M. Artigas
José M. Artigas
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
Andrés Gené SampedroAndrés Gené Sampedro
Andrés Gené Sampedro
JMJosé L. Menezo
José L. Menezo
To study the relationship between the optics quality of multifocal intraocular lenses (IOLs) and distance-corrected near, intermediate, and distance visual acuity to determine the degree to which optics quality must change to produce a significant difference in visual acuity. Fundación Oftalmológica del Mediterráneo, Valencia, Spain. Monocular distance-corrected visual acuity (decimal and logMAR) was measured at 4 m, 70 cm, and 30 cm under photopic and mesopic conditions in eyes with 1 of 3 multifocal IOL models. Visual acuity versus the "average modulation" of the IOL was assessed. The pupil diameter and patient age were similar between the 3 IOL groups (20 eyes each). A difference in average modulation (ie, optics quality) up to 15% did not produce significant differences in mean visual acuity between 2 groups; however, there was a significant difference in mean visual acuity between 2 groups when the average modulation values differed by at least 25%. The slope of the linear correlation between visual acuity and average modulation was 0.018 (r(2) = 0.91) under photopic conditions and 0.024 (r(2) = 0.089) under mesopic conditions. There was a strong linear correlation between IOL optics quality and visual acuity with distance correction under photopic conditions with a pupil of approximately 3.5 mm in a cohort in which the patient age was controlled. The correlation was similar under mesopic conditions. The eye's tolerance to modulation transfer function decay was approximately 15% of the average modulation value.

1 May 2012 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
AFAdelina Felipe
Adelina Felipe
JAJosé M. Artigas
José M. Artigas
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
PURPOSE: To evaluate the changes in optical quality when toric intraocular lenses (IOL) are rotated or tilted and to demonstrate that IOL rotation produces an increasing effect of aberrations. METHODS: Modulation transfer function (MTF) and average modulation were used to analyze the image quality of a toric IOL. The axis of the toric IOL was rotated 5°, 10°, 15°, 20°, 25°, and 30° in successive MTF measurements. The tilt values were 0° to 5°, in increments of 1°, plus a tilt of 15°. Pupil diameters of 3 and 5 mm were used. RESULTS: The MTF decay due to aberrations was more sensitive to rotation than tilt. The main decrement in the average modulation, of approximately 50% in both pupils, occurs when the IOL rotates from 0° to 5°. Between 0° and 1° tilt, the average modulation decreases approximately 25% for both pupils; with tilt >1°, the average modulation remains virtually unchanged. The points representing average modulation versus rotation angle are satisfactorily fitted by an exponential function, R=0.98. Average modulation versus tilt angle provides lower correlation degrees, R=0.91 and R=0.79, for 3- and 5-mm pupils, respectively. CONCLUSIONS: The MTF of the toric IOL decays with rotation and tilt, with greater decrement occurring in rotation from 0° to 5°. An asymptotic value exists in the average modulation decay, meaning that for angles higher than 15°, the average modulation of the toric IOL remains virtually constant.

2 June 2022 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
MLMaría Josefa Luque
María Josefa Luque
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
SOSusana Ortí-Navarro
Susana Ortí-Navarro
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
Background: To assess visual quality and stabilization of refractive changes in corneal edema patients after cataract surgery, using visual acuity (VA) and contrast sensitivity measurements. Methods: Sixty-one eyes were analysed, twenty-three with and thirty-eight without corneal edema. Uncorrected and corrected distance VA (UDVA and CDVA) were determined with an EDTRS chart, the contrast sensitivity function (CSF) under photopic and mesopic illumination conditions with a CVS-1000e chart, clinical refraction, and corneal topography. Measurements were taken preoperatively, 1–2 days, 1 and 3-months after surgery. Clinical refraction was converted to vector notation (M, J0, J45) and SPSS v26.0 was used for data analysis. Results: An improvement of VA was observed through the postoperative period; changes between visits were significant for CDVA in both groups and for UDVA in the edema sample. Significant astigmatic changes (J0,J45) between visits were not observed, but M values showed a hyperopic tendency in the edema group and a myopic shift in the control group that did not change between visits, with statistically significant differences between groups. Controls had significantly better contrast sensitivity at high spatial frequencies. Under mesopic conditions, global contrast sensitivity losses were observed in the edema group, which improved between visits in the middle frequency range. Conclusion: Corneal edema patients had a significant reduction of CDVA, and frequency-selective sensitivity losses that evidence a visual quality loss. Clinical refraction may improve visual quality, but in edema patients these losses are related to corneal changes, which did not change at three months after surgery.

1 April 2015 in Journal of Optometry
Verified
Journal Article
Open access
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
To determine the effect of main morphological types and grades of age-related cataracts on refractive error. We measured 276 subjects with optical compensation prior to the development of cataract. We evaluated 224 eyes with nuclear cataract, 125 with cortical cataract, and 103 with posterior subcapsular (PSC) cataract classified with LOCSIII. We measured visual acuity (VA) with their spectacles and best-corrected visual acuity (BCVA) with chart in decimal scale to obtain the optimal compensation with cataract. We evaluated the differences between compensations. A significant myopic shift was observed in nuclear cataract from low to mild grade (p=0.031), the same as for PSC cataract from mild to advanced grade (p=0.025). No significant changes were found for cortical cataract (p=0.462). Regarding astigmatism, we observed power changes in cortical cataract from low to mild grade (p=0.03) and axis changes in PSC from low to mild grade (p=0.02) and in nuclear cataract from mild to advanced grade (p=0.02). Cataract produces changes in patient's compensation which depend on severity and type of cataract. For nuclear and PSC cataract, we observed that the higher the grade of severity, the greater the myopic shift. Power astigmatic changes were found in cortical cataract and axis changes in PSC and nuclear cataract.