Mari Carmen Garcia-Domene

Dr. Mari Carmen Garcia-Domene

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2011 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
AFAdelina Felipe
Adelina Felipe
JAJosé M. Artigas
José M. Artigas
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
PAPablo Alcocer
Pablo Alcocer
To analyze changes in the eye's refractive properties when a toric intraocular lens (IOL) rotates. Fundación Oftalmológica del Mediterráneo, Valencia, Spain. Experimental study. The matrix definition of astigmatism was used in this theoretical study and compared with another vector representation. Two methods were compared: (1) The cylinder, C, resulting from the addition of 2 cylinders C(1) and C(2) whose axes form an angle a, is obtained by the addition of 2 vectors of values C(1) and C(2) forming an angle 2a; (2) the power matrix, F, of a thin astigmatic dioptric system that decomposes naturally into 3 orthogonal components: the purely spherical part F(nes,) the ortho-astigmatism F(or), and oblique astigmatism F(ob). The residual cylinder was one third of the corneal astigmatism when a toric IOL rotated ±10 degrees when the cylinder values for the cornea (C(1)) and IOL (C(2)) were equal. Nevertheless, in most cases C(1) is greater than C(2); therefore, the residual astigmatism did not change noticeably with small rotations. The angle of rotation, b, which annuls the astigmatism correction, could be obtained from the following: cos(π + 2b) = -r/2, with r being the ratio between the IOL and cornea cylinders. The 2 methods gave equivalent results. When the IOL cylinder had a value different from that of the corneal astigmatism, a better choice would be a lower, rather than higher, cylinder value to reduce residual astigmatism. In general, toric IOL rotations less than 10 degrees changed the eye's refraction less than 0.50 diopter. Thus, small axis rotations are not an obstacle for satisfactory astigmatism correction with toric IOLs. No author has a financial or proprietary interest in any material or method mentioned.

25 October 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
CBCeleste Briceno-Lopez
Celeste Briceno-Lopez
Neus Burguera-GiménezNeus Burguera-Giménez
Neus Burguera-Giménez
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
MLMaría Josefa Luque
María Josefa Luque
This systematic review investigates the prevalence and underlying causes of corneal edema following cataract surgery employing manual phacoemulsification. A comprehensive search encompassing databases such as PubMed, Embase, ProQuest, Cochrane Library, and Scopus was conducted, focusing on variables encompassing cataract surgery and corneal edema. Two independent reviewers systematically extracted pertinent data from 103 articles, consisting of 62 theoretical studies and 41 clinical trials. These studies delved into various aspects related to corneal edema after cataract surgery, including endothelial cell loss, pachymetry measurements, visual performance, surgical techniques, supplies, medications, and assessments of endothelial and epithelial barriers. This review, encompassing an extensive analysis of 3060 records, revealed significant correlations between corneal edema and endothelial cell loss during phacoemulsification surgery. Factors such as patient age, cataract grade, and mechanical stress were identified as contributors to endothelial cell loss. Furthermore, pachymetry and optical coherence tomography emerged as valuable diagnostic tools for assessing corneal edema. In conclusion, this systematic review underscores the link between corneal edema and endothelial cell loss in manual phacoemulsification cataract surgery. It highlights the relevance of factors like patient demographics and diagnostic modalities. However, further research is essential to unravel the complexities of refractive changes and the underlying mechanisms.

1 January 2011 in Ophthalmology
Verified
Journal Article
Closed access
JAJose M. Artigas
Jose M. Artigas
AFAdelina Felipe
Adelina Felipe
Amparo NaveaAmparo Navea
Amparo Navea
CACristina Artigas
Cristina Artigas
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene

1 May 2012 in Journal of Refractive Surgery
Verified
Journal Article
Closed access
AFAdelina Felipe
Adelina Felipe
JAJosé M. Artigas
José M. Artigas
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
PURPOSE: To evaluate the changes in optical quality when toric intraocular lenses (IOL) are rotated or tilted and to demonstrate that IOL rotation produces an increasing effect of aberrations. METHODS: Modulation transfer function (MTF) and average modulation were used to analyze the image quality of a toric IOL. The axis of the toric IOL was rotated 5°, 10°, 15°, 20°, 25°, and 30° in successive MTF measurements. The tilt values were 0° to 5°, in increments of 1°, plus a tilt of 15°. Pupil diameters of 3 and 5 mm were used. RESULTS: The MTF decay due to aberrations was more sensitive to rotation than tilt. The main decrement in the average modulation, of approximately 50% in both pupils, occurs when the IOL rotates from 0° to 5°. Between 0° and 1° tilt, the average modulation decreases approximately 25% for both pupils; with tilt >1°, the average modulation remains virtually unchanged. The points representing average modulation versus rotation angle are satisfactorily fitted by an exponential function, R=0.98. Average modulation versus tilt angle provides lower correlation degrees, R=0.91 and R=0.79, for 3- and 5-mm pupils, respectively. CONCLUSIONS: The MTF of the toric IOL decays with rotation and tilt, with greater decrement occurring in rotation from 0° to 5°. An asymptotic value exists in the average modulation decay, meaning that for angles higher than 15°, the average modulation of the toric IOL remains virtually constant.

29 September 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
MPMariola Penades-Fons
Mariola Penades-Fons
MLMaría Josefa Luque
María Josefa Luque
EFEster Fernández-López
Ester Fernández-López
JAJosé María Artigas
José María Artigas
We have assessed the spectral transmittance of the different layers of the human cornea in the ultraviolet (UV), visible, and near-infrared (IR) spectral ranges. Seventy-four corneal sample donors were included in the study. Firstly, the corneal transmittance was measured using a spectrophotometer. Then, all samples were fixed for histopathological analysis, which allowed us to measure the thickness of each corneal layer. Finally, the absorption coefficients of the corneal layers were computed by a linear model reproducing total transmittance. The results show that corneal transmission was almost in unity at the visible and IR ranges but not at the UV range, in which the layer with higher transmission is Descemet’s membrane, whereas the stroma showed the lowest transmittance. Regarding the absorption coefficient, the most absorptive tissue was Bowman’s layer, followed by the endothelium. Variations on transmittance due to changes in the stroma, Bowman’s layer, or Descemet layer were simulated, and important transmission increases were found due to stroma and Bowman changes. To conclude, we have developed a method to measure the transmittance and thickness for each corneal layer. All corneal layers absorb UV light to a greater or lesser extent. The absorption coefficient is higher for Bowman’s layer, while the stroma is the layer with the lowest transmittance due to its thickness. Variations in stroma thickness or changes in the corneal tissue of Bowman’s layer or the endothelium layer due to some pathologies or surgeries could affect, to a greater or lesser degree, the total transmission of the cornea. Thus, obtaining accurate absorption coefficients for different layers would help us to predict and compensate these changes.

2 June 2022 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
MDM Amparo Díez-Ajenjo
M Amparo Díez-Ajenjo
MLMaría Josefa Luque
María Josefa Luque
Cristina Peris-MartínezCristina Peris-Martínez
Cristina Peris-Martínez
SOSusana Ortí-Navarro
Susana Ortí-Navarro
MGMari Carmen Garcia-Domene
Mari Carmen Garcia-Domene
Background: To assess visual quality and stabilization of refractive changes in corneal edema patients after cataract surgery, using visual acuity (VA) and contrast sensitivity measurements. Methods: Sixty-one eyes were analysed, twenty-three with and thirty-eight without corneal edema. Uncorrected and corrected distance VA (UDVA and CDVA) were determined with an EDTRS chart, the contrast sensitivity function (CSF) under photopic and mesopic illumination conditions with a CVS-1000e chart, clinical refraction, and corneal topography. Measurements were taken preoperatively, 1–2 days, 1 and 3-months after surgery. Clinical refraction was converted to vector notation (M, J0, J45) and SPSS v26.0 was used for data analysis. Results: An improvement of VA was observed through the postoperative period; changes between visits were significant for CDVA in both groups and for UDVA in the edema sample. Significant astigmatic changes (J0,J45) between visits were not observed, but M values showed a hyperopic tendency in the edema group and a myopic shift in the control group that did not change between visits, with statistically significant differences between groups. Controls had significantly better contrast sensitivity at high spatial frequencies. Under mesopic conditions, global contrast sensitivity losses were observed in the edema group, which improved between visits in the middle frequency range. Conclusion: Corneal edema patients had a significant reduction of CDVA, and frequency-selective sensitivity losses that evidence a visual quality loss. Clinical refraction may improve visual quality, but in edema patients these losses are related to corneal changes, which did not change at three months after surgery.