To compare the effectiveness and side effects of lactated Ringer's solution (LR) and 0.9% saline (NS) in the treatment of rhabdomyolysis induced by doxylamine intoxication. In this 15-month-long prospective randomised single-blind study, after excluding 8 patients among 97 doxylamine-intoxicated patients, 28 (31%) patients were found to have developed rhabdomyolysis and were randomly allocated to NS group (n = 15) or LR group (n = 13). After 12 h of aggressive hydration (400 ml/h), urine/serum pH was found to be significantly higher in the LR group, and serum Na+/Cl- levels to be significantly higher in the NS group. There were no significant differences in serum K+ level and in the time taken for creatine kinase normalisation. The amount of sodium bicarbonate administered and the frequency administration of diuretics was significantly higher in the NS group. Unlike the NS group, the LR group needed little supplemental sodium bicarbonate and did not develop metabolic acidosis. LR is more useful than NS in the treatment of rhabdomyolysis induced by doxylamine intoxication.
Objective: To compare the usefulness for training of a porcine model (larynx, trachea, and pig skin) and a manikin model using a Portex cricothyrotomy kit (PCK). Methods: In a prospective randomised crossover trial, participants in the airway workshop performed crico-thyrotomy using a PCK on the porcine and manikin models (Tracheostomy Trainer and Case). The porcine model was made with larynxes and trachea from freshly slaughtered pigs and covered with a piece of thinned pigskin stapled to a wooden board. Participants were asked to assess the following: reality of skin turgor; difficulty with skin penetration, landmark recognition and procedure; reality of the model; and preference for each model using a visual analogue scale (VAS) of 0–10 cm. The VAS scores for each model were compared. Results: 49 participants were included in the study. Mean (SD) VAS scores for the reality of skin turgor, degree of difficulty with skin penetration and landmark recognition were higher with the porcine model than with the manikin model (7.0 (2.1) vs 4.7 (2.0), 6.4 (2.4) vs 3.6 (2.2), 5.1 (2.2) vs 4.2 (2.5), respectively). There was no difference between the models in the difficulty of the procedure (5.0 (2.4) vs 4.7 (3.2)). The porcine model had a higher VAS score for overall reality and preference of the model (7.1 (2.0) vs 4.8 (2.3) and 7.1 (2.0) vs 4.8 (2.2), respectively). Conclusion: The porcine model is a more useful training tool than the manikin model for cricothyrotomy with PCK because of its reality and similarity to human anatomy.
10 December 2023 in Clinical and Experimental Emergency Medicine
O(On Behalf Of The Society Emergency And Critical Care Imaging (Secci)
On Behalf Of The Society Emergency And Critical Care Imaging (Secci)
+13
Point-of-care ultrasound (POCUS) is a rapidly developing technology that has the potential to revolutionize emergency and critical care medicine. The use of POCUS can improve patient care by providing real-time clinical information. However, appropriate usage and proper training are crucial to ensure patient safety and reliability. This article discusses the various applications of POCUS in emergency and critical care medicine, the importance of training and education, and the future of POCUS in medicine.
Objective: To compare the acceptability and preference between manikin models and fresh frozen cadaver (FFC) for direct laryngoscopic orotracheal intubation training. Methods: In this prospective crossover trial, participants in the airway workshop performed direct laryngoscopic orotracheal intubation on four airway training manikins: Airway Management Trainer (Ambu, St Ives, UK), Airway Trainer (Laerdal, Medical, Stavanger, Norway), Airsim (Trucorp, Belfast, Northern Ireland) and “Bill 1” (VBM, Sulz, Germany), and FFC. Participants were asked to access the following: reality of jaw mobility, difficulty with mouth opening, reality of neck flexibility, difficulty with intubation, overall model reality and model preference for each model using a visual analogue scale (VAS) of 0–10 cm. The VAS scores for each model were compared. Results: Fifty-six participants were included in the study. The FFC had a highest VAS score for reality of jaw mobility, overall reality and preference of model. Trucorp manikin and Laerdal manikin followed cadaver. There were no significant statistical differences between Trucorp manikin and Laerdal manikin. In difficulty with mouth opening and difficulty with intubation, Trucorp manikin had the lowest VAS score. Conclusion: The FFC is a more realistic and preferred model for direct laryngoscopic orotracheal intubation training. Trucorp and Laerdal manikin can be used as alternative models.