Je Hyeok Oh

Prof. Je Hyeok Oh

Chung-Ang University
orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2012 in The Journal of Emergency Medicine
Verified
Journal Article
Closed access
TPTae Ung Park
Tae Ung Park
Je Hyeok OhJe Hyeok Oh
Je Hyeok Oh
ICIn Taek Chang
In Taek Chang
SLSang Jin Lee
Sang Jin Lee
SKSung Eun Kim
Sung Eun Kim
KLKwang Jung Lee
Kwang Jung Lee

10 December 2023 in Clinical and Experimental Emergency Medicine
Verified
Journal Article
Open access
PDF file
WCWook Jin Choi
Wook Jin Choi
YCYoung Soon Cho
Young Soon Cho
YHYoung Rock Ha
Young Rock Ha
Je Hyeok OhJe Hyeok Oh
Je Hyeok Oh
HLHeekyung Lee
Heekyung Lee
O(On Behalf Of The Society Emergency And Critical Care Imaging (Secci)
On Behalf Of The Society Emergency And Critical Care Imaging (Secci)
Point-of-care ultrasound (POCUS) is a rapidly developing technology that has the potential to revolutionize emergency and critical care medicine. The use of POCUS can improve patient care by providing real-time clinical information. However, appropriate usage and proper training are crucial to ensure patient safety and reliability. This article discusses the various applications of POCUS in emergency and critical care medicine, the importance of training and education, and the future of POCUS in medicine.

1 November 2008 in Resuscitation
Verified
Journal Article
Closed access
Je Hyeok OhJe Hyeok Oh
Je Hyeok Oh
SLSang Jin Lee
Sang Jin Lee
SKSung Eun Kim
Sung Eun Kim
KLKwang Jung Lee
Kwang Jung Lee
JCJu Won Choe
Ju Won Choe
CKChan Woong Kim
Chan Woong Kim


22 October 2009 in Emergency Medicine Journal
Verified
Journal Article
Closed access
PDF file
JCJunho Cho
Junho Cho
Je Hyeok OhJe Hyeok Oh
Je Hyeok Oh
YPYoo Seok Park
Yoo Seok Park
IPIncheol Park
Incheol Park
SCSung Phil Chung
Sung Phil Chung
Objectives: The correct chest compression technique was emphasised to enhance the result of cardiopulmonary resuscitation in the 2005 guidelines. The present study compared the effects of different bed heights, including a bed at knee height, on the performance of chest compressions. Methods: Twenty-four healthcare providers participated in this study. Knee height was defined as the baseline bed height. Bed heights were adjusted to 10 and 20 cm above the baseline and 10 and 20 cm below the baseline. At the five bed heights, chest compressions were performed for 2 minutes, and the compression rate was maintained at 100 per minute, with audible feedback. Results: The mean compression depths (MCD) were 28.3 mm (SD 10.7; knee height +20 cm), 32.3 mm (SD 9.2; knee height +10 cm), 32.7 mm (SD 8.5; knee height), 32.3 mm (SD 9.0; knee height −10 cm) and 31.1 mm (SD 8.5; knee height −20 cm). The MCD was significantly lower at knee height plus 20 cm (p<0.001). Conclusion: The performance of chest compressions decreased when the bed height was 20 cm higher than the knee height of the rescuer.

1 October 2018 in European Journal of Emergency Medicine
Verified
Journal Article
Closed access
PDF file
SLSang Yoon Lee
Sang Yoon Lee
JHJun Young Hong
Jun Young Hong
Je Hyeok OhJe Hyeok Oh
Je Hyeok Oh
SSSun-Han Son
Sun-Han Son
Objectives: The two-finger technique (TFT) using the index-middle fingers of the right hand (TFT-R23) was recently confirmed to produce deeper chest compression depth (CCD) compared with the TFT using any other fingers. This study was carried out to confirm whether the TFT-R23 would be as effective as the two-thumb technique (TTT). In addition, individual finger strengths were measured to identify the reasons why the TTT and TFT-R23 produced deeper CCD than any other methods. Methods: This prospective randomized cross-over trial compared TTT with TFT-R23. A total of 37 doctors conducted 2 min single-rescuer cardiopulmonary resuscitation using TTT and TFT-R23 in a random order using a 3-month-old sized infant manikin laid on the floor. The chest compression to ventilation ratio was set to 15 : 2. In addition, finger strengths were measured using a pinch meter. Results: The actual CCD of the TTT was significantly deeper than that of the TFT-R23 (41.3±1.3 vs. 39.8±1.5 mm, P<0.001). Although the hands-off time of the TTT was significantly longer than that of the TFT-R23 (55.6±5.7 vs. 53.6±5.8 s, P=0.002), the mean difference was only 2.0±3.7 s (95% confidence interval: 0.755–3.245). The finger strength of the TTT was significantly higher than that of TFT-R23 (23.8±10.1 vs. 13.7±5.1 kg, P<0.001). Conclusion: The TTT produced deeper CCD compared with that of the TFT-R23 because the finger strength of the TTT was significantly higher than that of the TFT-R23.