Tatiana Romanova

Dr. Tatiana Romanova


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 June 2021 in Molecules
Verified
Journal Article
Open access
PDF file
YIYuri D. Ivanov
Yuri D. Ivanov
TRTatiana Romanova
Tatiana Romanova
Kristina MalsagovaKristina Malsagova
Kristina Malsagova
TPTatyana Pleshakova
Tatyana Pleshakova
AAAlexander Archakov
Alexander Archakov
The review covers some research conducted in the field of medical and biomedical application of devices based on silicon sensor elements (Si-NW-sensors). The use of Si-NW-sensors is one of the key methods used in a whole range of healthcare fields. Their biomedical use is among the most important ones as they offer opportunities for early diagnosis of oncological pathologies, for monitoring the prescribed therapy and for improving the people’s quality of life.

1 August 2020 in Coatings
Verified
Journal Article
Open access
PDF file
Kristina MalsagovaKristina Malsagova
Kristina Malsagova
TPTatyana Pleshakova
Tatyana Pleshakova
RGRafael A. Galiullin
Rafael A. Galiullin
ISIvan D. Shumov
Ivan D. Shumov
AKAndrey Kozlov
Andrey Kozlov
YIYuri D. Ivanov
Yuri D. Ivanov
Herein, we have demonstrated highly sensitive real-time biospecific detection of a protein marker of hepatitis C—the core antigen of hepatitis C virus (HCVcoreAg)—using a nanowire (NW) biosensor. The primary element of the NW-biosensor is a chip with p-type conductance, bearing silicon-on-insulator (SOI) nanowire structures on its surface. The nanowire structures are fabricated by gas-plasma treatment and electron beam lithography. The detection specificity was provided by sensitization of the sensor surface with aptamers against HCVcoreAg. The influence of buffer pH on the sensor response signal was studied. The effect of reverse polarity of the biosensor response signal with change from the acidic buffer pH to the neutral one was found. The lowest detectable HCVcoreAg concentration was determined to be 2.0 × 10−15 M in both acidic (pH 5.1) and neutral (pH 7.4) buffer solution. The proposed aptamer-sensitized sensor was also successfully applied to detect HCVcoreAg in serum samples of hepatitis C patients.

30 June 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
YIYuri D. Ivanov
Yuri D. Ivanov
TPTatyana Pleshakova
Tatyana Pleshakova
ISIvan D. Shumov
Ivan D. Shumov
AKAndrey Kozlov
Andrey Kozlov
TRTatiana Romanova
Tatiana Romanova
VZVadim Ziborov
Vadim Ziborov
The influence of liquid motion in flow-based systems on the aggregation state of an enzyme and on its enzymatic activity was studied, with horseradish peroxidase (HRP) as an example. Our experiments were carried out in a setup modeling the flow section of the biosensor communication with a measuring cell containing a protein solution. Studies were conducted for a biosensor measuring cell located along the axis of a spiral-moving liquid flow. The aggregation state of the protein was determined with an atomic force microscopy-based sensor (AFM sensor). It has been demonstrated that upon flowing of water through silicone biosensor communications, an increased aggregation of HRP protein was observed, but, at the same time, its enzymatic activity did not change. Our results obtained herein are useful in the development of models describing the influence of liquid flow in biosensor communications on the properties of enzymes and other proteins. This is particularly important for the development of serologic protein biosensors, which are beginning to be used for the early diagnosis of oncological diseases (such as brain cancer, prostate cancer, breast cancer etc.). The results obtained herein should also be taken into account when considering possible changes in hemodynamics due to increased protein aggregation.

2 October 2020 in Chemosensors
Verified
Journal Article
Open access
PDF file
Kristina MalsagovaKristina Malsagova
Kristina Malsagova
TPTatyana Pleshakova
Tatyana Pleshakova
RGRafael A. Galiullin
Rafael A. Galiullin
AKAndrey Kozlov
Andrey Kozlov
TRTatiana Romanova
Tatiana Romanova
YIYuri D. Ivanov
Yuri D. Ivanov
Herein, we report the development of a highly sensitive nanotechnology-based system—silicon-on-insulator nanowire biosensor for the revelation of microRNAs (miRNAs), associated with the development of glioma in the human. In this system, a sensor chip, bearing an array of silicon nanowire structures, is employed. The sensor chip is fabricated using a top-down technology. In our experiments reported herein, we demonstrated the detection of DNA oligonucleotide (oDNA), which represents a synthetic analogue of microRNA-363 associated with the development of glioma. To provide biospecific detection of the target oligonucleotides, the surface of the nanowire structures is modified with oligonucleotide probes; the latter are complementary to the target ones. The concentration limit of the target oligonucleotide detection, attained using our nanowire biosensor, is at the level of DL~10−17 M. The revelation of the elevated level of glioma-associated miRNA in plasma is also demonstrated.