The aim of this study was to clarify the effect of attachment on tooth movement produced by a plastic aligner. Closing of a diastema, in which the maxillary right and left central incisors moved bodily, was simulated using a finite element method. Long-term orthodontic movements of the maxillary dentition were simulated by accumulating the initial displacement of teeth produced by elastic deformation of the periodontal ligament. The incisor tipped and rotated just after placement of the aligner irrespective of the attachment. After a sufficiently long time, the incisor was upright and moved bodily in the aligner with attachment, but the incisor remained tipped in the aligner without attachment. It was demonstrated that the attachment was effective for achieving bodily movement.
This study aimed to create a biomaterial from titanium dioxide (TiO2), which has been known to have photocatalytic and bone formation promoting effects. I expected that anatase titanium dioxide-based implants could promote bone augmentation and induce bone formation. Powdery anatase TiO2 was compression molded and sintered at 700, 800, 900, and 1000 °C to prepare sintered compact samples. X-ray diffraction and scanning electron microscopy were used to observe the surface of these samples. Furthermore, mouse osteoblast-like cells (MC3T3-E1 cell line) were seeded on the samples sintered at different temperatures, and cell proliferation was observed to evaluate the cell proliferation of the samples. The sample sintered at 700 °C was composed of anatase TiO2. The samples sintered at 800 °C and 900 °C were confirmed to consist of a mixture of anatase and rutile TiO2 crystalline phases. Moreover, the sample sintered at 700 and 800 °C, which contained anatase TiO2, showed remarkable photocatalytic activity. Those samples sintered at 1000 °C were transformed to the rutile TiO2. The cell proliferation after 7–14-days culturing revealed that cells cultured on the 700 °C sample decreased in number immediately after initiation of culturing. The cells cultured on TiO2 sintered at 900 °C markedly proliferated over time with an increase in the alkaline phosphatase activity, showing good MC3T3-E1 cell compatibility of the samples. The sample sintered at 1000 °C, which is rutile TiO2, showed the highest increase.
The aim of this study was to evaluate the effect of additional silane treatment on the immediate and aged microtensile bond strength (µTBS) between resin-based composite (RBC) post-and-core build-up material and an RBC CAD/CAM block. Twelve sample blocks (12 mm × 14 mm × 9 mm) were prepared using RBC post-and-core build-up material and were divided into six groups: Kerr Silane Primer (Sil) + OptiBond eXTRa Universal adhesive (EXA); OptiBond eXTRa Universal Primer (EXP) + EXA; Sil + OptiBond Universal (OBU); OBU; Sil + OptiBond Solo Plus (OSP); and OSP. Each treated sample was luted to a CAD/CAM block using an NX3 Nexus Third-Generation instrument. After storage in 37 °C water for 1 week, microspecimens were fabricated, and μTBS was tested immediately or after further immersion in water at 37 °C for 6 months. The failure mode of each specimen was determined using stereomicroscopy and scanning electron microscopy. For the immediate groups, no significant difference in µTBS was found between specimens with or without silane treatment for each adhesive (p > 0.05). For the aged groups, silane treatment significantly decreased µTBS for OptiBond eXTRa Universal (p < 0.05). Our findings indicate that additional silane treatment prior to the application of adhesive did not enhance µTBS.
The quad-helix and W-arch are commonly used appliances for expanding the dental arch in orthodontic treatment. However, differences in performance between these two expanders remain unclear, and no guidelines exist for selecting one over the other. The purpose of this study was to investigate whether there were differences in dental arch expanding ability between these appliances. Maxillary arch expansions were simulated using the finite element method. The expander was assumed to be an elastic beam, while the teeth and alveolar bone were treated as rigid bodies. The periodontal ligament (PDL) was modeled as a nonlinear elastic material. The teeth moved in the same direction as the initial movement caused by the elastic deformation of the PDL. The right and left canines, premolars, and first molars were expanded symmetrically in either parallel or fan shapes. When the wire diameter of the W-arch was set to 0.032 inches its stiffness became equivalent to that of a quad-helix with a wire diameter of 0.036 inches. Canines and premolars were expanded through tipping movements. The molars initially tipped buccally, then became upright and moved bodily. Both expanders expanded the arch in almost the same manner. There was no difference in arch expansion ability between the W-arch made of 0.032-inch wire and the quad-helix made of 0.036-inch wire. The W-arch may be preferred as the first choice due to its simpler structure compared to the quad-helix.
The purpose of this study was to compare the mechanical efficacies of the various loop springs in the extraction space closure. The long-term movement of the teeth was simulated by the finite element method. It was assumed that the tooth moved in the same direction as the initial movement due to elastic deformation of the periodontal ligament. After the spring was activated, the initial movement was calculated, and then the alveolar socket was moved. By repeating this calculation, the teeth moved by accumulating the initial movement. The anterior teeth first tipped lingually and then became upright; thereby, the extraction space was closed for a fixed distance. In all cases, the gable bends were effective in increasing the closing speed. A higher loop increased the closing distance. When the helical loop was replaced with the vertical loop, the closing distance decreased. A spring made of thick wire increased the closing speed but decreased the closing distance. No spring increased both the closing distance and the closing speed at the same time. In clinical settings, an appropriate spring should be selected for each case by giving priority to either the closing distance or speed.
To clarify the mechanics of tooth movement produced by a unique distalizer, Class II Carriere Motion appliance (CMA), in which the maxillary canine is connected to the maxillary first molar with a stiff bar, long-term tooth movement was simulated by the finite element method (FEM). The FEM models of the maxillary canine, premolars, and first molar were made based on a dental study model. The periodontal ligament (PDL) was constructed on the root and assumed to be a nonlinear elastic material. The teeth and the alveolar bone were assumed to be rigid bodies. The tooth moved by accumulating the initial movement produced by the elastic deformation of the PDL. When retraction force was applied to the canine from the mandibular dentition, the canine tipped or rotated clockwise and extruded due to the vertical component of the retraction force. The molar and premolars also tipped and moved distally, but hardly extruded because the vertical force did not act on them. As a result of these tooth movements, the canine protruded from the dentition. An interproximal space was created between the canine and the lateral incisor. These movement patterns were similar to those in other clinical studies using the CMA.