Thiago Viana Miranda Lima

Dr. Thiago Viana Miranda Lima

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 December 2021 in Cancers
Verified
Journal Article
Open access
PDF file
NMNick Van der Meulen
Nick Van der Meulen
KSKlaus Strobel
Klaus Strobel
TLThiago Viana Miranda Lima
Thiago Viana Miranda Lima
Developments throughout the history of nuclear medicine have involved improvements in both instrumentation and radionuclides, which have been intertwined. Instrumentation developments always occurred during the search to improving devices’ sensitivity and included advances in detector technology (with the introduction of cadmium zinc telluride and digital Positron Emission Tomography—PET-devices with silicon photomultipliers), design (total body PET) and configuration (ring-shaped, Single-Photon Emission Computed Tomography (SPECT), Compton camera). In the field of radionuclide development, we observed the continual changing of clinically used radionuclides, which is sometimes influenced by instrumentation technology but also driven by availability, patient safety and clinical questions. Some areas, such as tumour imaging, have faced challenges when changing radionuclides based on availability, when this produced undesirable clinical findings with the introduction of unclear focal uptakes and unspecific uptakes. On the other end of spectrum, further developments of PET technology have seen a resurgence in its use in nuclear cardiology, with rubidium-82 from strontium-82/rubidium-82 generators being the radionuclide of choice, moving away from SPECT nuclides thallium-201 and technetium-99m. These continuing improvements in both instrumentation and radionuclide development have helped the growth of nuclear medicine and its importance in the ever-evolving range of patient care options.

3 October 2021 in Diagnostics
Verified
Journal Article
Open access
PDF file
TLThiago Viana Miranda Lima
Thiago Viana Miranda Lima
SGSilvano Gnesin
Silvano Gnesin
KSKlaus Strobel
Klaus Strobel
MPMaria del Sol Pérez
Maria del Sol Pérez
JRJustus Erasmus Roos
Justus Erasmus Roos
NMNick Van der Meulen
Nick Van der Meulen
Scandium-44 has been proposed as a valuable radionuclide for Positron Emission Tomography (PET). Recently, scandium-43 was introduced as a more favorable option, as it does not emit high-energy γ-radiation; however, its currently employed production method results in a mixture of scandium-43 and scandium-44. The interest in new radionuclides for diagnostic nuclear medicine critically depends on the option for image-based quantification. We aimed to evaluate and compare the quantitative capabilities of scandium-43/scandium-44 in a commercial PET/CT device with respect to more conventional clinical radionuclides (fluorine-18 and gallium-68). With this purpose, we characterized and compared quantitative PET data from a mixture of scandium-43/scandium-44 (~68% scandium-43), scandium-44, fluorine-18 and gallium-68, respectively. A NEMA image-quality phantom was filled with the different radionuclides using clinical-relevant lesion-to-background activity concentration ratios; images were acquired in a Siemens Biograph Vision PET/CT. Quantitative accuracy with scandium-43/scandium-44 in the phantom’s background was within 9%, which is in agreement with fluorine-18-based PET standards. Coefficient of variance (COV) was 6.32% and signal recovery in the lesions provided RCmax (recovery coefficient) values of 0.66, 0.90, 1.03, 1.04, 1.12 and 1.11 for lesions of 10-, 13-, 17-, 22-, 28- and 37-mm diameter, respectively. These results are in agreement with EARL reference values for fluorine-18 PET. The results in this work showed that accurate quantitative scandium-43/44 PET/CT is achievable in commercial devices. This may promote the future introduction of scandium-43/44-labelled radiopharmaceuticals into clinical use.

10 July 2020 in Frontiers in Physics
Verified
Journal Article
Open access
PDF file
TLThiago Viana Miranda Lima
Thiago Viana Miranda Lima
SGSilvano Gnesin
Silvano Gnesin
ENEgbert Nitzsche
Egbert Nitzsche
POPablo G. Ortega
Pablo G. Ortega
Cristina MuellerCristina Mueller
Cristina Mueller
NMNicholas P. van der Meulen
Nicholas P. van der Meulen
Scandium (Sc) is a promising candidate for theranostic applications due to the existence of radioisotopes suitable for both imaging and therapy. A “proof-of-concept” study regarding first-in-human use of 44Sc for imaging metastatic neuroendocrine tumors was reported recently, however, quantitative assessment of 44Sc-based PET images was not performed. The aim of this study was to evaluate quantitative capabilities of 44Sc-PET using a commercial PET scanner. The NEMA/IEC body phantom with 44Sc was acquired according to the local protocol used for whole-body oncological [18F]FDG PET examinations. Additionally, we characterized the signal recovery (recovery coefficient—RC) according to the iteration number. For all reconstructions, pertinent image corrections (normalization, dead time, activity decay, random coincidence, and attenuation) were applied. Presently, 44Sc scatter corrections are not optimized and could, thus, result in quantitative bias. To investigate the best option, the data were reconstructed using different available scatter corrections (relative -RelSC- and absolute -AbsSC-) and an additional prompt-gamma correction (PGC). System cross-calibration with the local dose calibrator (BGcal) and image noise, expressed by the coefficient of variation (COV), were evaluated in the homogeneous background region (5 kBq/mL) of the phantom. Maximum (RCmax) and 50% threshold recovery coefficients, corrected for background (RCA50), were measured for all spherical inserts (25 kBq/mL) of the phantom. Acceptable COV (<15%) was achievable with low iteration numbers (<3). BGcal differences were low: mean BGcal were 77.8, 81.3, and 86.7%, for RelSC, AbsSC, and PGC, respectively. RC values exceeded the present RC range recommended for [18F]FDG procedures. Using the iterations to be evaluated, RCA50 ranged from 29.9 to 59.9% for the smallest lesion (spherical insert of 10 mm diameter) and from 45.5 to 80.3% (13 mm), 66.4 to 75.6% (17 mm), 71.7 to 75.7% (22 mm), 75.1 to 78.6% (28 mm), and 76.7 to 80.9% (37 mm) for the, respectively spherical inserts. The results of this study show that clinical 44Sc-PET imaging has the potential to provide signal recovery in lesions of different sizes comparable to current 18F-PET standards. In order to improve the quantitative accuracy of 44Sc PET, optimized corrections are still necessary and will be investigated further in future.

30 March 2022 in Journal of Radiological Protection
Verified
Journal Article
Open access
PDF file
LSLeopold Simma
Leopold Simma
JFJuergen Fornaro
Juergen Fornaro
NSNikolai Stahr
Nikolai Stahr
MLMarkus Lehner
Markus Lehner
JRJustus E Roos
Justus E Roos
TLThiago Viana Miranda Lima
Thiago Viana Miranda Lima
We aimed to evaluate the impact of a low-dose whole-body computed tomography (WBCT) protocol on radiation doses in paediatric major trauma patients. Retrospective cohort study of paediatric trauma patients (<16 years) at a national level 1 paediatric trauma centre (PTC) over a 6 year period prior and post introduction of a low-dose WBCT protocol (2014–2019). Demographic data, patient characteristics, CT device, and exposure information including scan range, dose-length product, and volume CT dose index were collected. Effective dose (ED) and exposure parameters were compared before and after protocol introduction. Forty-eight patients underwent WBCT during the study period. Prior to introduction of the low-dose protocol (n = 18), the ED was 20.6 mSv (median 20.1 ± 5.3 mSv [range 12.5–30.7]). After introduction of the low-dose WBCT protocol (n = 30), mean ED was 4.8 mSv (median 2.6 ± 5.0 [range: 0.8–19.1]). This resulted in a reduction of 77% in mean ED (p value <0.001). Significant radiation dose reduction of 77% can be achieved with low-dose WBCT protocols in PTCs.

1 October 2020 in European Journal of Hybrid Imaging
Verified
Journal Article
Open access
PDF file
TLThiago Viana Miranda Lima
Thiago Viana Miranda Lima
UBUjwal Bhure
Ujwal Bhure
MLMaria de Sol Pérez Lago
Maria de Sol Pérez Lago
YTYannick Thali
Yannick Thali
SMSavo Matijasevic
Savo Matijasevic
KSKlaus Strobel
Klaus Strobel
Novel reconstruction algorithms, such as xSPECT Bone, are gaining more and more importance in Nuclear Medicine. With xSPECT Bone, the reconstructed emission image is enhanced by the information obtained in the corresponding CT image. The CT defines tissue classes according to the Hounsfield units. In the iterative reconstruction, each tissue class is handled separately in the forward projection step, and all together in the back projection step. As a consequence, xSPECT Bone reconstruction generates images with improved boundary delineation and better anatomic representation of tracer activity. Applying this technique, however, showed that artefacts may occur, when no uptake regions, like metal implants, exhibit fictitious uniform tracer uptake. Due to limitations in spatial resolution in gamma cameras, the xSPECT Bone reconstructed image resulted in spill-out activity from surrounding high uptake region being uniformly distributed over the metal implants. This new technology of xSPECT Bone reconstruction in general enhances the image quality of SPECT/CT; however, the potential introduction of specific artefacts which inadvertently come along with this new technology and their frequency have not yet been addressed in the literature. Therefore, the purpose of this work was to identify and characterize these specific metal artefacts (the so-called shining metal artefact) in order to reduce false positives and avoid potentially misdiagnosing loosened or infected implants. In this work, we report five cases imaged with bone SPECT/CT of 5 anatomical regions (foot, elbow, spine, shoulder, ribs and knee). All cases demonstrated “shining metal artefacts” in xSPECT Bone reconstruction. While xSPECT Bone reconstruction algorithm significantly improves image quality for the diagnosis of bone and joint disorders with SPECT/CT, specific “shining metal artefacts” caused by the xSPECT Bone have to be recognized in order to avoid image misinterpretation suggesting metallic implant loosening or possible infection. The simultaneous analysis of conventionally reconstructed SPECT images (for Siemens the Flash3D reconstruction) helps to avoid misinterpretation of potential artefacts introduced by xSPECT Bone reconstruction.

16 May 2024 in Journal of Radiological Protection
Verified
Journal Article
Open access
LDLaura Dupont
Laura Dupont
CAChristoph Aberle
Christoph Aberle
DBDiomidis Botsikas
Diomidis Botsikas
MIMichael Ith
Michael Ith
TLThiago Viana Miranda Lima
Thiago Viana Miranda Lima
MMMarta Sans Merce
Marta Sans Merce
The aim of this study is to propose diagnostic reference levels (DRLs) values for mammography in Switzerland. For the data collection, a survey was conducted among a sufficient number of centres, including five University hospitals, several cantonal hospitals, and large private clinics, covering all linguistic regions of Switzerland to be representative of the clinical practice. The data gathered contained the mean glandular dose (MGD), the compressed breast thickness (CBT), the mammography model and the examination parameters for each acquisition. The data collected was sorted into the following categories: 2D or digital breast tomosynthesis (DBT) examination, craniocaudal (CC) or mediolateral oblique (MLO) projection, and eight categories of CBT ranging from 20 mm to 100 mm in 10 mm intervals. A total of 24 762 acquisitions were gathered in 31 centres on 36 mammography units from six manufacturers. The analysis showed that the data reflects the practice in Switzerland. The results revealed that the MGD is larger for DBT than for 2D acquisitions for the same CBT. From 20–30 mm to 90–100 mm of CBT, the 75th percentile of the MGD values obtained increased from 0.81 mGy to 2.55 mGy for 2D CC acquisitions, from 0.83 mGy to 2.96 mGy for 2D MLO acquisitions, from 1.22 mGy to 3.66 mGy for DBT CC acquisitions and from 1.33 mGy to 4.04 mGy for DBT MLO acquisitions. The results of the survey allow us to propose Swiss DRLs for mammography according to the examination type (2D/DBT), projection (CC/MLO) and CBT. The proposed values are very satisfactory in comparison with other studies.