Norberto Quispe-López

Dr. Norberto Quispe-López

Surgery, University of Salamanca, Salamanca, Castille-Leon, Spain
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 June 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Norberto Quispe-LópezNorberto Quispe-López
Norberto Quispe-López
SMSoraya Martín-Martín
Soraya Martín-Martín
CGCristina Gómez-Polo
Cristina Gómez-Polo
OFOscar Figueras-Alvarez
Oscar Figueras-Alvarez
MSMaría Isabel Sánchez-Jorge
María Isabel Sánchez-Jorge
Javier MonteroJavier Montero
Javier Montero
Some evidence supports the influence of implant macro-design on primary stability. Additionally, tactile perception can be used to assess implant stability when placing the implant. This research aimed to quantify the primary and secondary stability of three implant systems with two different macro geometries (cylindrical and conical) determined based on the insertion torque and the implant stability quotient (ISQ) at the moment of implant placement as a function of implant-related factors (length, width, dental arch, and implant location in the arch), intraoperative factors (bone density determined subjectively by the clinician’s tactile perception), and patient-related factors (age, gender, and bone density determined objectively based on cone beam computed tomography (CBCT). Methods: 102 implants from three implant systems with two different macro geometries (conical and cylindrical) were placed in 53 patients. The insertion torque, the ISQ at the implant placement (ISQ0), and the bone quality according to the clinician’s tactile sensation were recorded on the day of the surgery. After a three-month healing period, the ISQ was re-evaluated (ISQ3). Results: The cylindrical implants exhibited significantly higher insertion torque and ISQ values at the moment of the surgery and after three months compared to the conical implants. The cylindrical implants also showed significantly lower indices of tactile evaluation of bone quality during the implant placement surgery. However, no differences were demonstrated in the bone density measured objectively using CBCT. (4) Conclusions: The cylindrical implants achieved the highest values for primary stability (Newtons × centimeter (Ncm) and ISQ) and secondary stability (ISQ after three months). The insertion torque was the variable that most influenced the ISQ on the day of the surgery. The implant location (incisors–canines, bicuspids–molars) and the implant macro geometry were the variables that most influenced the secondary stability (ISQ at three months).

5 October 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Javier MonteroJavier Montero
Javier Montero
YGYasmina Guadilla
Yasmina Guadilla
Javier FloresJavier Flores
Javier Flores
BPBeatriz Pardal-Peláez
Beatriz Pardal-Peláez
Norberto Quispe-LópezNorberto Quispe-López
Norberto Quispe-López
IZIbrahim Dib Zaitun
Ibrahim Dib Zaitun
This study aims to assess the treatment outcomes (functional and subjective) of full-arch fixed hybrid rehabilitations made of PEEK (poly-ether-ether-ketone) with milled crowns of nano-filled composite (NFC) supported on four to six implants. In this randomized clinical trial, 34 edentate patients in the upper and/or the lower jaws were treated with the fixed hybrid dentures. In 16 patients (47.1% of the sample), the implants were loaded immediately (IL) by means of a provisional fixed rehabilitation made of PMMA (polymethylmethacrylate) screwed on Multi-Unit (MU) abutments connected after emplacement of the implant; however, in the counterparts (n = 18) these MU abutments were covered by healing caps and were left unloaded during two months (conventional loading protocol—CL), when all patients received a fixed hybrid PEEK-NFC rehabilitation on the upper and/or the lower jaw. Treatment outcomes were assessed 12 months after prostheses delivery. Functional outcomes were calculated according to masticatory performance, estimated by mixing ability tests of two colored chewing gums after ten chewing strokes, by the occlusal force/area recorded by pressure-sensitive sheets, and by electromyography of masseters and temporal muscles at maximum biteforce. The subjective outcomes of the treatment were assessed using both the oral satisfaction scale (visual analog scale) and the Spanish version of the Oral Health Impact Profile (OHIP-20). The findings of the present study showed that treatment with fixed PEEK-NFC hybrid prostheses significantly improved the masticatory performance, bite force, occlusal pattern, quality of life, and satisfaction, with the IL group being those with significantly higher occlusal bite forces and greater satisfaction in comparison with CL group. It should be concluded that PEEK-NFC hybrid prostheses can improve several patient-centered outcomes and that loading protocol significantly affects the patient’s self-rated satisfaction.

12 May 2021 in Materials
Verified
Journal Article
Open access
PDF file
Javier MonteroJavier Montero
Javier Montero
Alicia Becerro ÁlvarezAlicia Becerro Álvarez
Alicia Becerro Álvarez
BPBeatriz Pardal-Peláez
Beatriz Pardal-Peláez
Norberto Quispe-LópezNorberto Quispe-López
Norberto Quispe-López
JBJuan Francisco B. Blanco
Juan Francisco B. Blanco
CGCristina Gómez-Polo
Cristina Gómez-Polo
Clinicians should be aware of the main methods and materials to face the challenge of bone shortage by manufacturing customized grafts, in order to repair defects. This study aims to carry out a bibliographic review of the existing methods to manufacture customized bone scaffolds through 3D technology and to identify their current situation based on the published papers. A literature search was carried out using “3D scaffold”, “bone regeneration”, “robocasting” and “3D printing” as descriptors. This search strategy was performed on PubMed (MEDLINE), Scopus and Cochrane Library, but also by hand search in relevant journals and throughout the selected papers. All the papers focusing on techniques for manufacturing customized bone scaffolds were reviewed. The 62 articles identified described 14 techniques (4 subtraction + 10 addition techniques). Scaffold fabrication techniques can be also be classified according to the time at which they are developed, into Conventional techniques and Solid Freeform Fabrication techniques. The conventional techniques are unable to control the architecture of the pore and the pore interconnection. However, current Solid Freeform Fabrication techniques allow individualizing and generating complex geometries of porosity. To conclude, currently SLA (Stereolithography), Robocasting and FDM (Fused deposition modeling) are promising options in customized bone regeneration.

23 July 2024 in Journal of Dentistry
Verified
Journal Article
Open access
Norberto Quispe-LópezNorberto Quispe-López
Norberto Quispe-López
YGYasmina Guadilla
Yasmina Guadilla
CGCristina Gómez-Polo
Cristina Gómez-Polo
Nansi López-ValverdeNansi López-Valverde
Nansi López-Valverde
Javier FloresJavier Flores
Javier Flores
Javier MonteroJavier Montero
Javier Montero
To evaluate the bone changes around equicrestal and subcrestal implants, analyzing the effect of abutment height [short abutments (SA < 2 mm) and long abutments (LA > 2 mm)] and the three components of the peri‑implant soft-tissue phenotype. Twenty-six patients received 71 implants that were placed according to supracrestal tissue height (STH) in an equicrestal (n = 17), shallow subcrestal ≈1 mm (n = 33), or deep subcrestal ≈2 mm (n = 21) position. After 3 months of healing, rehabilitation was completed using metal-ceramic crowns on multi-unit abutments of 1.5 mm, 2.5 mm, or 3.5 mm in height, depending on the prosthetic space and STH. Longitudinal clinical parameters (STH, mucosal thickness, and keratinized mucosa width) and radiographic data [bone remodelling and marginal bone loss (MBL)] were collected at 3, 6, 12, and 24 months postsurgery. The gain in STH was significantly greater around the implants placed in a subcrestal ≈2 mm position. After 2 years, the mean change in bone remodelling in the SA group was significantly greater than in the LA group. According to the multiple linear regression, bone remodelling depends primarily on abutment height (β = -0.43), followed by crestal position (β = 0.34), and keratinized mucosa width (β = -0.22), while MBL depends on abutment height (β = -0.37), and the patient's age (β = -0.36). Implants placed in an equicrestal or subcrestal ≈1 mm position with LA undergo less bone remodelling, while the lowest level of MBL occurs in subcrestal ≈2 mm implants with LA. Differing soft-tissue thicknesses combined with the use of either SA or LA produced significant intergroup differences in bone remodelling and MBL. Abutment height is the most powerful predictor variable affecting bone remodelling and MBL. Depending on the dimensions of the peri‑implant soft-tissue phenotype, placing the implants subcrestally may also be a viable option to decrease bone remodelling and, consequently, reduce MBL. identification number: NCT05670340.

21 March 2022 in Medicina
Verified
Journal Article
Open access
PDF file
CGCristina Gómez-Polo
Cristina Gómez-Polo
MGMiguel Gómez-Polo
Miguel Gómez-Polo
Norberto Quispe-LópezNorberto Quispe-López
Norberto Quispe-López
MMMaría Portillo Muñoz
María Portillo Muñoz
Javier MonteroJavier Montero
Javier Montero
Background and Objectives: To study the validity and the degree of representability of the toothguide 3D Master, with 26 physically shade tabs, on the natural tooth colour on a sample of the Spanish population. Materials and Methods: Natural tooth colour was measured in a sample of 1361 Spanish participants of both genders distributed within an age range of 18 and 89 years of age. The colour coordinates were calculated and the frequency of the 26 physically shade tabs of the toothguide as well as the “intermediate shades” (without physical representation in toothguide) through the Easyshade Compact (Vita-Zahnfabrik) spectrophotometer using the 3D Master System nomenclature. The colour differences between the “intermediate shades” were calculated using the Euclidean formula (ΔEab*). The program used for the present descriptive statistical analysis of the results was SAS 9.1.3. Results: A total of 49 “intermediate shades” were registered in 816 participants (60%). The colour coordinates of the 49 ‘intermediate shades’ cover colour coordinates ranging from 0M1.5 (L* 100.0, C* 7.70, h* 112.2) to 5M2.5 (L* 56.8, C* 35.8, h* 78.5). Not all possible 3D Master System’s “intermediate shades” were registered in the population studied. 82.4% of the colour differences among the “intermediate shades” were clinically unacceptable (ΔEab* ≥ 5.5 units). Conclusions: Only 40% of the population studied presented a natural tooth colour belonging to the 3D Master Toothguide’s physical shade tabs.

6 August 2021 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
Javier MonteroJavier Montero
Javier Montero
IZIbrahim Dib Zaitun
Ibrahim Dib Zaitun
YGYasmina Guadilla
Yasmina Guadilla
Javier FloresJavier Flores
Javier Flores
BPBeatriz Pardal-Peláez
Beatriz Pardal-Peláez
CGCristina Gómez-Polo
Cristina Gómez-Polo
This study aims to assess the treatment outcomes (functional and subjective) of mandibular overdentures retained on two implants with or without an immediate loading protocol. In this randomized clinical trial, twenty fully edentulous patients were treated with a mandibular two-implant-retained overdenture and a complete new maxillary denture. In half of the sample, the implants were loaded immediately by means of VulkanLoc® abutments after emplacement of the implant, but in the counterparts, these VulkanLoc® abutments were connected to implants two months after the surgery (conventional protocol), and until that time the dentures were retained by healing abutments. Treatment outcomes were assessed at two, six, and twelve months after surgery. Functional outcomes were calculated according to masticatory performance, estimated by the mixed fraction of a two-coloured chewing gum after five, ten, and fifteen chewing strokes, by the occlusal force recorded by pressure-sensitive sheets, and by the bioelectrical muscular activity. The subjective outcomes of the treatment were assessed using both the oral satisfaction scale (visual analogue scale) and the Spanish version of the Oral Health Impact Profile (OHIP-20). The findings of the present study show that new complete dentures resulted in significant improvements in chewing ability, patient satisfaction, and oral health-related quality of life and that subsequent implant-retained overdentures produced further and faster significant improvements. The loading protocol may influence those positive self-reported outcomes rather than the objective functional evaluations.