Ying Wen

Dr. Ying Wen

College of Aviation Meteorology, Civil Aviation Flight University of China, Guanghan 618307, China
orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2021 in Atmosphere
Verified
Journal Article
Open access
PDF file
Chao WangChao Wang
Chao Wang
Ying WenYing Wen
Ying Wen
LWLijuan Wang
Lijuan Wang
XKXianbiao Kang
Xianbiao Kang
YLYunfeng Liu
Yunfeng Liu
By employing multi-reanalysis daily datasets and station data, this study focuses on the evolution characteristics of the daily-scale Silk Road pattern (SRP) and its effect on summer temperatures in the Yangtze River Valley (YRV). The results manifest that the evolution characteristics of positive- and negative-phase SRP (referred to SRP+ and SRP−) exhibit marked distinctions. The anomaly centers of SRP+ over West Central Asia (WCA) and Mongolia emerge firstly, vanishing simultaneously one week after peak date; however, the Far East (FE) anomaly centers can persist for a longer period. The SRP− starts with the WCA and FE centers, with a rapid decline in the strength of the WCA center and preservation of other anomaly centers after its peak. In the vertical direction, daily-scale SRP mainly concentrates in the mid-to-upper troposphere. Baroclinicity accounts for its early development and barotropic instability process favors the maintenance. Moreover, the SRP+ (SRP−) is inextricably linked to heat wave (cool summer) processes in the YRV. Concretely, before the onset of SRP+ events, an anomalous anticyclone and significant negative vorticities over East Asia related to SRP+ favor the zonal advance between the South Asia high (SAH) and western Pacific subtropical high (WPSH), inducing local descents over YRV area. The sinking adiabatic warming and clear-sky radiation warming can be considered as the possible causes for the YRV heat waves. The adiabatic cooling with the local ascents leads to more total cloud cover (positive precipitation anomalies) and less solar radiation incident to surface of the YRV, inducing the cool summer process during SRP−.

23 October 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
YNYang Ning
Yang Ning
Ying WenYing Wen
Ying Wen
ZSZheng Shi
Zheng Shi
HZHongyu Zheng
Hongyu Zheng
CJCuicui Ji
Cuicui Ji
MLMaowen Liu
Maowen Liu
There has been a growing demand for clean energy in recent years, with the advancement of the carbon neutrality vision. Wind power has occupied a significant percentage of clean energy sources. Usually deployed in open fields, on mountaintops, and in offshore areas, wind turbines are particularly vulnerable to lightning strikes due to their unique operational characteristics. Therefore, accurately evaluating the lightning strike risk of wind turbines is an important issue that should be addressed. Current IEC standards lack a physically grounded approach for calculating the equivalent collection area, leading to an overestimation of this value. This paper employs an upward leader initiation model to develop a novel calculation method for the equivalent collection area of wind turbines. By considering the impact of upward leader channel initiation and development, the model demonstrates accuracy through comparison with observational data (0.7761 strikes/year), showing only a −7.1% discrepancy. This study also examines the impact of various blade rotation angles, stepped leader speeds, and peak current of the return stroke on the equivalent collection area. Results indicate that the lightning strike distance specified in IEC standards underestimates the equivalent collection area due to neglecting the upward leader channel, resulting in significant differences compared to our approach, with a maximum deviation of up to 313.12%.

4 February 2025 in Atmosphere
Verified
Journal Article
Open access
PDF file
YNYang Ning
Yang Ning
ZSZheng Shi
Zheng Shi
Ying WenYing Wen
Ying Wen
SYShuangwu Yuan
Shuangwu Yuan
HZHaohui Zhang
Haohui Zhang
Lightning is a long-gap high-current discharge event in nature, and its enormous discharge energy can cause structural damage to struck objects. Relevant studies have shown that aircraft in the air are exposed to a higher risk of lightning strikes than ground objects. However, most studies on aircraft lightning strikes have used static models, and there are still shortages of research objects under high-speed movements. Therefore, it is necessary to conduct an investigation of the lightning strike characteristics of aircraft under dynamic conditions to ensure flight safety fully. In this study, the lightning strike characteristics of airfoil under dynamic conditions have been simulated by studying two variables, airspeed and angle of attack, while employing the Leader Progression Model (LPM). The results show that adjustments in the angle of attack cause changes in the atmospheric pressure field, and a maximum pressure difference of up to 5.44 × 104 Pa is observed at the angle of attack of 15°, which results in a change in the average electric field strength Estr, leading to a 33.63% difference in the upward leader trigger height. At an airspeed equal to 120 m/s, the trigger height in the low-pressure region is only 54.7% of that in the high-pressure region (435 m and 795 m, respectively). A higher lightning strike risk is found in areas of higher air pressure and is positively correlated with angle of attack and airspeed.

15 August 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
XZXiaoxu Zhang
Xiaoxu Zhang
TZTinglong Zhang
Tinglong Zhang
Ying WenYing Wen
Ying Wen
ZLZhe Li
Zhe Li
YLYunfeng Liu
Yunfeng Liu
JGJunming Gong
Junming Gong
Near-surface atmospheric electric field and wind observations collected during the springs of 2025 and 2026 at the edge of the Tengger Desert in Minqin, Gansu Province, were used to investigate electric-field characteristics under fair-weather, dust-devil, blowing-sand, and dust-storm conditions. Under fair-weather conditions, the electric field was directed downward, with a mean absolute magnitude of approximately 0.32 kV·m⁻¹; it remained relatively stable at night, whereas its fluctuations increased during the day. Dust devils approaching the observation site produced pulse-like increases in the electric field and brief polarity reversals. During blowing-sand and dust-storm events, the electric field was predominantly upward, with peak magnitudes exceeding 10 and 35 kV·m⁻¹, respectively, and exhibited multistage evolution, multiple peaks, and second-scale fluctuations. Abrupt changes in wind direction often coincided with electric-field troughs. The correspondence between wind speed and the electric field was weak at the 1-s scale but became markedly stronger after 1-min and 10-min averaging. Wavelet analysis showed that, during blowing-sand events, significant wavelet power in both variables was concentrated mainly at periods of 5–20 min, whereas the significant wavelet power of the electric field during dust storms extended to longer periods. At periods longer than approximately 50 min, wind speed and the electric field generally varied in phase, whereas their phase relationships were more complex at shorter periods. These results indicate that the electric field during sand-and-dust events is jointly influenced by wind speed, charged-particle transport, space-charge accumulation, and the nonuniform spatial distribution of charge.