JORGE ARES

Dr. JORGE ARES

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Francisco Avila GomezFrancisco Avila Gomez
Francisco Avila Gomez
JAJORGE ARES
JORGE ARES
CMConcepción Vidosa Marcellán
Concepción Vidosa Marcellán
MCM. Victoria Collados
M. Victoria Collados
LRLaura Remón
Laura Remón
The optical quality of an image depends on both the optical properties of the imaging system and the physical properties of the medium in which the light travels from the object to the final imaging sensor. The analysis of the point spread function of the optical system is an objective way to quantify the image degradation. In retinal imaging, the presence of corneal or cristalline lens opacifications spread the light at wide angular distributions. If the mathematical operator that degrades the image is known, the image can be restored through deconvolution methods. In the particular case of retinal imaging, this operator may be unknown (or partially) due to the presence of cataracts, corneal edema, or vitreous opacification. In those cases, blind deconvolution theory provides useful results to restore important spatial information of the image. In this work, a new semi-blind deconvolution method has been developed by training an iterative process with the Glare Spread Function kernel based on the Richardson-Lucy deconvolution algorithm to compensate a veiling glare effect in retinal images due to intraocular straylight. The method was first tested with simulated retinal images generated from a straylight eye model and applied to a real retinal image dataset composed of healthy subjects and patients with glaucoma and diabetic retinopathy. Results showed the capacity of the algorithm to detect and compensate the veiling glare degradation and improving the image sharpness up to 1000% in the case of healthy subjects and up to 700% in the pathological retinal images. This image quality improvement allows performing image segmentation processing with restored hidden spatial information after deconvolution.

CMConcepción Vidosa Marcellán
Concepción Vidosa Marcellán
Francisco Avila GomezFrancisco Avila Gomez
Francisco Avila Gomez
JAJORGE ARES
JORGE ARES
LRLaura Remón
Laura Remón
Peripheral refraction can lead to the development of myopia. The aim of this study was to compare relative peripheral refraction (RPR) in the same cohort of uncorrected (WCL) and corrected eyes with two different soft contact lenses (CL) designed for myopia control, and to analyze RPR depending on the patient’s refraction. A total of 228 myopic eyes (114 healthy adult subjects) (−0.25 D to −10.00 D) were included. Open-field autorefraction was used to measure on- and off- axis refractions when uncorrected and corrected with the two CLs (dual focus (DF) and extended depth of focus (EDOF)). The RPR was measured every 10° out to 30° in a temporal-nasal orientation and analyzed as a component of the power vector (M). The average RPR for all subjects was hyperopic when WCL and when corrected with EDOF CL design, but changed to a myopic RPR when corrected with DF design. Significant differences were found between RPR curves with both CLs in all the eccentricities (Bonferroni correction p < 0.008, except 10°N). An incremental relationship between relative peripheral refraction at 30 degrees and myopia level was found. It is concluded that the two CLs work differently at the periphery in order to achieve myopia control.

17 April 2024 in Optics Letters
Verified
Journal Article
Closed access
DYDiana Gargallo Yebra
Diana Gargallo Yebra
AEAnabel Martínez Espert
Anabel Martínez Espert
SPSara Perches
Sara Perches
MCM. Victoria Collados
M. Victoria Collados
LRLaura Remón
Laura Remón
JAJORGE ARES
JORGE ARES
A new, to the best of our knowledge, optical element designed to compensate regular astigmatism while exhibiting increased tolerance to rotational misalignment is introduced. The element incorporates an optical design based on concentric annular regions with slightly different cylindrical axis angular positions. To assess visual quality performance as a function of rotation, retinal image simulation and clinical assessments with an adaptive optics visual simulator were carried out. The results demonstrate the superior performance of the newly proposed element in the presence of rotational errors when compared to traditional solutions.

4 February 2011 in Optics Communications
Verified
Journal Article
Closed access
JAJORGE ARES
JORGE ARES
JAJusto Arines Arines
Justo Arines Arines
Salvador BaráSalvador Bará
Salvador Bará

1 July 2020 in EDULEARN Proceedings
Verified
Conference Paper
Closed access
PDF file
DRDavid Ranz
David Ranz
LRLaura Remón
Laura Remón
RSRosana Sanz Segura
Rosana Sanz Segura
JAJORGE ARES
JORGE ARES
Information about the paper titled "APPLICATION OF A CASE STUDY METHODOLOGY. STUDY DESIGN AND IMPLEMENTATION FOR A MULTIDISCIPLINARY GROUP" at IATED Digital Library

10 April 2024 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
Francisco Avila GomezFrancisco Avila Gomez
Francisco Avila Gomez
PCPilar Casado
Pilar Casado
CMConcepción Vidosa Marcellán
Concepción Vidosa Marcellán
LRLaura Remón
Laura Remón
JAJORGE ARES
JORGE ARES
SMSofia Zaira Otin Mallada
Sofia Zaira Otin Mallada
Spatial aspects of visual performance are usually evaluated through visual acuity charts and contrast sensitivity (CS) tests. CS tests are generated by vanishing the contrast level of the visual charts. However, the quality of retinal images can be affected by both ocular aberrations and scattering effects and none of those factors are incorporated as parameters in visual tests in clinical practice. We propose a new computational methodology to generate visual acuity charts affected by ocular scattering effects. The generation of glare effects on the visual tests is reached by combining an ocular straylight meter methodology with the Commission Internationale de l’Eclairage’s (CIE) general disability glare formula. A new function for retinal contrast assessment is proposed, the subjective straylight function (SSF), which provides the maximum tolerance to the perception of straylight in an observed visual acuity test. Once the SSF is obtained, the subjective straylight index (SSI) is defined as the area under the SSF curve. Results report the normal values of the SSI in a population of 30 young healthy subjects (19 ± 1 years old), a peak centered at SSI = 0.46 of a normal distribution was found. SSI was also evaluated as a function of both spatial and temporal aspects of vision. Ocular wavefront measures revealed a statistical correlation of the SSI with defocus and trefoil terms. In addition, the time recovery (TR) after induced total disability glare and the SSI were related; in particular, the higher the RT, the greater the SSI value for high- and mid-contrast levels of the visual test. No relationships were found for low contrast visual targets. To conclude, a new computational method for retinal contrast assessment as a function of ocular straylight was proposed as a complementary subjective test for visual function performance.