Patrice Masson

Dr. Patrice Masson

Département de génie mécanique – Mechanical Engineering, Université de Sherbrooke, Sherbrooke, PQ J1K 2R1, Canada

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2018 in Structural Health Monitoring
Verified
Journal Article
Closed access
VSValentin Serey
Valentin Serey
NQNicolas Quaegebeur
Nicolas Quaegebeur
PMPhilippe Micheau
Philippe Micheau
PMPatrice Masson
Patrice Masson
MCMichel Castaings
Michel Castaings
MRMathieu Renier
Mathieu Renier
Non-destructive testing and structural health monitoring systems based on ultrasonic guided waves propagation are particularly used in civil engineering or aerospace applications. Guided waves are commonly employed as they propagate through large distances and can inspect the entire cross-section of the structure. In order to optimize the sensitivity to a specific damage type, it is often preferable to generate a carefully selected pure mode. Although single-mode generation has been achieved for Lamb waves in infinite plate-like structures, such generation is much harder in a rectangular bar since less conventional modes propagate in finite cross-section waveguides. This article presents a general methodology for mode selective generation in a finite cross-section waveguide, using multiple transducers. Obtaining modal identification through conventional spatial Fourier transform on a longitudinal scan has proven to be inconvenient for waveguides with a two-dimensional cross-section. An alternative technique is proposed, consisting in the decomposition over the modal basis of the three displacement components measured across the bar width at the bar surface. The methodology is applied to the single-mode generation within an aluminum bar instrumented with eight piezoelectric transducers bonded to the surface. The modal basis is obtained with a semi-analytical finite element method. Numerical simulations and experiments using a three-dimensional laser Doppler vibrometer are conducted in order to validate the methodology.

15 May 2018 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
Marc-Andre BeginMarc-Andre Begin
Marc-Andre Begin
PCPatrick Chouinard
Patrick Chouinard
LLLouis-Philippe Lebel
Louis-Philippe Lebel
PMPatrice Masson
Patrice Masson
YPYann Pasco
Yann Pasco
ABAlain Berry
Alain Berry
Passive air springs are the golden standard in heavy vehicle seat suspensions, as they provide economical means to isolate drivers from road disturbances. They are nevertheless likely to expose drivers to vibration levels higher than recommended by the ISO-2631-1 standard over a typical 8-h shift. Although existing commercial active seat suspensions have proven their superiority over passive suspensions, practical limitations such as cost or lack of overall dynamic performance have slowed down their widespread adoption. Controlled slippage magnetorheological (MR) actuators are a promising alternative because they offer a dynamic performance similar to direct-drive motors in a packaging and cost similar to economical geared motors. This paper is the first to experimentally assess the overall closed-loop performance of an active seat suspension powered by a controlled slippage MR actuator including vibration attenuation, power consumption, and seat travel. Unlike semiactive MR actuators such as MR dampers that have been extensively studied, controlled slippage MR actuators are fully active and offer a significantly better performance for rough road conditions. The active seat was tested in a laboratory on a vibrating platform recreating the floor acceleration profile of a dump truck rolling on a quarry road. The seat was also tested on an actual highway truck rolling on a roadway. Results show that with a linear-quadratic-Gaussian controller, the proposed active suspension effectively reduces floor vibrations by a factor of 2-3, while using an average power consumption of 86 W and having an average relative travel range of 1-10 mm root mean square. These results fall in line with commercially available active seat suspensions.

16 August 2020 in Structural Health Monitoring
Verified
Journal Article
Closed access
PDF file
VSValentin Serey
Valentin Serey
NQNicolas Quaegebeur
Nicolas Quaegebeur
MRMathieu Renier
Mathieu Renier
PMPhilippe Micheau
Philippe Micheau
PMPatrice Masson
Patrice Masson
MCMichel Castaings
Michel Castaings
Ultrasonic guided waves are used in non-destructive testing and structural health monitoring solutions for long-range inspection, in applications ranging from Civil Engineering to Aerospace. In order to ease the inspection process, it is generally preferable to generate a carefully selected single mode. Although single mode Lamb wave generation is not difficult to achieve in infinite plate-like structures, with carefully polarized or sized piezoceramic elements, for example, such selective generation is much more difficult in a rectangular bar. In this article, we consider the propagation along a thin plate of finite rectangular cross section, which corresponds to a rectangular bar. The finite lateral width leads to a greater density of modes compared to an infinite plate. The authors have previously addressed this matter and developed a methodology for the selective generation of modes in the harmonic regime. This article extends this methodology to selective mode generation for finite time excitation, such as bursts. Results are presented for single mode generation of A0,0 and A0,1 in an aluminum bar instrumented with eight piezoelectric transducers. The waveguide modal basis is calculated with the two-dimensional semi-analytical finite element method, and measurements are conducted using a three-dimensional laser-Doppler vibrometer. To illustrate the potential of the method for structural health monitoring purposes, the detection of a defect simulated by a pair of magnets placed at various positions over the bar width is demonstrated.

16 June 2016 in Smart Materials and Structures
Verified
Journal Article
Closed access
PDF file
PMPeyman Yazdanpanah Moghadam
Peyman Yazdanpanah Moghadam
NQNicolas Quaegebeur
Nicolas Quaegebeur
PMPatrice Masson
Patrice Masson
A novel multi-element piezoelectric transducers (MEPT) is designed, optimized, machined and experimentally tested to improve structural health monitoring systems for mode-selective generation of guided waves (GW) in an isotropic structure. GW generation using typical piezoceramics makes the signal processing and consequently damage detection very complicated because at any driving frequency at least two fundamental symmetric ( S 0 ) and antisymmetric ( A 0 ) modes are generated. To prevent this, mode selective transducer design is proposed based on MEPT. A numerical method is first developed to extract the interfacial stress between a single piezoceramic element and a host structure and then used as the input of an analytical model to predict the GW propagation through the thickness of an isotropic plate. Two novel objective functions are proposed to optimize the interfacial shear stress for both suppressing unwanted mode(s) and maximizing the desired mode. Simplicity and low manufacturing cost are two main targets driving the design of the MEPT. A prototype MEPT is then manufactured using laser micro-machining. An experimental procedure is presented to validate the performances of the MEPT as a new solution for mode-selective GW generation. Experimental tests illustrate the high capability of the MEPT for mode-selective GW generation, as unwanted mode is suppressed by a factor up to 170 times compared with the results obtained with a single piezoceramic.

5 September 2013 in Structural Health Monitoring
Verified
Journal Article
Closed access
KMKyle R Mulligan
Kyle R Mulligan
NQNicolas Quaegebeur
Nicolas Quaegebeur
PMPatrice Masson
Patrice Masson
LBLouis-Philippe Brault
Louis-Philippe Brault
CYChunsheng Yang
Chunsheng Yang
The compensation of the degradation of the bonding layer of piezoceramics used in structural health monitoring is addressed in this article. A simple admittance model is first used to measure and extract the variation of admittance parameters using the same acquisition chain which is used by the structural health monitoring system for damage monitoring. More precisely, the method uses measurable changes in physical transducer modal damping at frequencies around piezoceramic resonance to estimate the extent of degradation. Then, a finite element model is used to obtain calibration curves linking the variations in transducer modal damping to amplitude and phase of the ultrasonic signals generated or measured by the piezoceramics. Such calibration curves are obtained by simulating with the FEM the effect of varying the bonding layer coverage area and Young’s modulus on (a) admittance and (b) amplitude and phase of the ultrasonic signals. From this, a signal correction factor is developed for the dominant bonding layer coverage area degradation failure mode to compensate for the changes in amplitude and phase of guided waves generated and measured by degraded piezoceramic transducers. The measured modal damping determines the amount of bonding layer degradation from the simulated modal damping calibration curves and then the quantified bonding layer degradation amount selects the amplitude and phase correction to be applied to measured signals from the calibration curves. The benefits of the signal correction factor are demonstrated below piezoceramic resonance to improve damage imaging and localization using the Embedded Ultrasonic Structural Radar algorithm (delay and sum method) when a single transducer in a sparse array of transducers fixed to an aluminum plate is damaged due to the close proximity of drop-weight impacts. Up to a certain damage extent, the signal correction factor could allow an extension of the service life of the structural health monitoring system.

21 May 2012 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
NQNicolas Quaegebeur
Nicolas Quaegebeur
PMPatrice Masson
Patrice Masson
PMPhilippe Micheau
Philippe Micheau
NMNezih Mrad
Nezih Mrad
Classically, damage detection or dispersion curve determination using piezoceramic-generated guided waves has been based on analysis of propagation properties of multiple narrowband excitation signals. However, dispersion and multimodal propagation impair the determination of propagation properties. More recently, it has been proposed to consider broadband excitations for both damage imaging and group velocity estimation. Among existing transducer technologies, although laser excitation is prone to practical limitations in terms of dimensions and generated amplitudes, it allows generation of noncontact, point-like broadband displacement. Thus, broadband generation of guided waves using piezoceramics can be envisioned. However, direct impulse response measurements are limited by the generated amplitude, leading to low SNR measurements. For this purpose, chirp excitations have been proposed using variable-frequency bursts, leading to phase and amplitude variations with respect to the frequency, such that this approach is not suitable for precise estimation of time of flight (ToF) or modal amplitude. In this paper, a sub-band decomposition technique that allows high-SNR measurements of impulse response in a given frequency range is proposed. Broadband excitation is decomposed over a given number of frequency sub-bands, generated by a piezoceramic element and measurement is performed using a laser Doppler vibrometer (LDV) or a piezoceramic sensor. Application to experimental estimation of group velocity and damage detection in pitchcatch configuration is proposed. It is shown that the proposed method allows damage estimation without a priori knowledge of the damage size, whereas narrowband techniques can fail at specific wavelengths.