Marc-Andre Begin

Mr. Marc-Andre Begin

Massachusetts Institute of Technology
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 December 2016 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
PMPhilipp Muller
Philipp Muller
Marc-Andre BeginMarc-Andre Begin
Marc-Andre Begin
TSThomas Schauer
Thomas Schauer
TSThomas Seel
Thomas Seel
Due to their relative ease of handling and low cost, inertial measurement unit (IMU)-based joint angle measurements are used for a widespread range of applications. These include sports performance, gait analysis, and rehabilitation (e.g., Parkinson's disease monitoring or poststroke assessment). However, a major downside of current algorithms, recomposing human kinematics from IMU data, is that they require calibration motions and/or the careful alignment of the IMUs with respect to the body segments. In this article, we propose a new method, which is alignment-free and self-calibrating using arbitrary movements of the user and an initial zero reference arm pose. The proposed method utilizes real-time optimization to identify the two dominant axes of rotation of the elbow joint. The performance of the algorithm was assessed in an optical motion capture laboratory. The estimated IMU-based angles of a human subject were compared to the ones from a marker-based optical tracking system. The self-calibration converged in under 9.5 s on average and the rms errors with respect to the optical reference system were 2.7° for the flexion/extension and 3.8° for the pronation/supination angle. Our method can be particularly useful in the field of rehabilitation, where precise manual sensor-to-segment alignment as well as precise, predefined calibration movements are impractical.

1 July 2019
Verified
Conference Paper
Closed access
DLDaniel Laidig
Daniel Laidig
DLDustin Lehmann
Dustin Lehmann
Marc-Andre BeginMarc-Andre Begin
Marc-Andre Begin
TSThomas Seel
Thomas Seel
Inertial Measurement Units (IMUs) are used to track the motion of kinematic chains in a wide variety of robotic and biomedical applications. However, inertial motion tracking is severely limited by the fact that magnetic fields are inhomogeneous in indoor environments and near electronic devices. Methods that use only accelerations and angular rates for orientation estimation yield no absolute heading information and suffer from heading drift. To overcome this limitation, we propose a novel method that exploits an orientation-based kinematic constraint in joints with two degrees of freedom (DoF), such as cardan joints, saddle joints, the human wrists, elbow or ankles. The method determines the relative heading of the joint segments in real time by minimization of a nonlinear cost function. A filter for singularity treatment ensures accurate tracking during motion phases for which the cost function minimum is ambiguous. We experimentally validate the method in metacarpophalangeal (MCP) joints between the palm and the fingers. Accurate relative orientation tracking is achieved continuously despite several singular motion phases and even though the heading components of the 6D orientations drift by more than 360 degrees within ten minutes. The proposed method overcomes a major limitation of inertial motion tracking and thereby facilitates the use of this technology in robotic and biomechanical applications.

15 May 2018 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
Marc-Andre BeginMarc-Andre Begin
Marc-Andre Begin
PCPatrick Chouinard
Patrick Chouinard
LLLouis-Philippe Lebel
Louis-Philippe Lebel
PMPatrice Masson
Patrice Masson
YPYann Pasco
Yann Pasco
ABAlain Berry
Alain Berry
Passive air springs are the golden standard in heavy vehicle seat suspensions, as they provide economical means to isolate drivers from road disturbances. They are nevertheless likely to expose drivers to vibration levels higher than recommended by the ISO-2631-1 standard over a typical 8-h shift. Although existing commercial active seat suspensions have proven their superiority over passive suspensions, practical limitations such as cost or lack of overall dynamic performance have slowed down their widespread adoption. Controlled slippage magnetorheological (MR) actuators are a promising alternative because they offer a dynamic performance similar to direct-drive motors in a packaging and cost similar to economical geared motors. This paper is the first to experimentally assess the overall closed-loop performance of an active seat suspension powered by a controlled slippage MR actuator including vibration attenuation, power consumption, and seat travel. Unlike semiactive MR actuators such as MR dampers that have been extensively studied, controlled slippage MR actuators are fully active and offer a significantly better performance for rough road conditions. The active seat was tested in a laboratory on a vibrating platform recreating the floor acceleration profile of a dump truck rolling on a quarry road. The seat was also tested on an actual highway truck rolling on a roadway. Results show that with a linear-quadratic-Gaussian controller, the proposed active suspension effectively reduces floor vibrations by a factor of 2-3, while using an average power consumption of 86 W and having an average relative travel range of 1-10 mm root mean square. These results fall in line with commercially available active seat suspensions.

22 January 2022 in Sensors
Verified
Journal Article
Open access
PDF file
Marc-Andre BeginMarc-Andre Begin
Marc-Andre Begin
Ian HunterIan Hunter
Ian Hunter
The success of robot localization based on visual odometry (VO) largely depends on the quality of the acquired images. In challenging light conditions, specialized auto-exposure (AE) algorithms that purposely select camera exposure time and gain to maximize the image information can therefore greatly improve localization performance. In this work, an AE algorithm is introduced which, unlike existing algorithms, fully leverages the camera’s photometric response function to accurately predict the optimal exposure of future frames. It also features feedback that compensates for prediction inaccuracies due to image saturation and explicitly balances motion blur and image noise effects. For validation, stereo cameras mounted on a custom-built motion table allow different AE algorithms to be benchmarked on the same repeated reference trajectory using the stereo implementation of ORB-SLAM3. Experimental evidence shows that (1) the gradient information metric appropriately serves as a proxy of indirect/feature-based VO performance; (2) the proposed prediction model based on simulated exposure changes is more accurate than using γ transformations; and (3) the overall accuracy of the estimated trajectory achieved using the proposed algorithm equals or surpasses classic exposure control approaches. The source code of the algorithm and all datasets used in this work are shared openly with the robotics community.

1 September 2016 in Journal of Biomechanics
Verified
Journal Article
Closed access
GMG. Masson
G. Masson
Marc-Andre BeginMarc-Andre Begin
Marc-Andre Begin
MPM. Lopez Poncelas
M. Lopez Poncelas
SPS.-K. Pelletier
S.-K. Pelletier
JLJ.-L. Lessard
J.-L. Lessard
DRD. Rancourt
D. Rancourt

16 July 2021 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
Marc-Andre BeginMarc-Andre Begin
Marc-Andre Begin
RPRyan Poon
Ryan Poon
Ian HunterIan Hunter
Ian Hunter
The successful control of robotic manipulators mounted on flexible bases such as suspended mobile robots requires more sophisticated controllers than those employed for fixed-based manipulators. Solutions proposed in the literature often require expert knowledge to tune control parameters or lack stability guarantees when the dynamics of the flexible base lie close to those of the manipulator in the frequency domain. This letter addresses these issues by introducing a tuning procedure for the linear PID gains of a manipulator mounted on a flexible base that guarantees stability. A publicly available Python library implementing this procedure is also introduced to streamline the process for a wide array of user-defined models. The performance of a controller generated using this procedure is shown in simulations for a 3DOF manipulator mounted on an 8-legged tracked vehicle.