Yuye Wang

Prof. Dr. Yuye Wang

School of Precise Instrument and Opto-Electronics, Tianjin University, Tianjin 300072, China
orcid

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2017 in Photonics Research
Verified
Journal Article
Open access
PDF file
DYDexian Yan
Dexian Yan
YWYuye Wang
Yuye Wang
Degang XuDegang Xu
Degang Xu
Pengxiang LiuPengxiang Liu
Pengxiang Liu
CYChao Yan
Chao Yan
JYJianquan Yao
Jianquan Yao
We have demonstrated a high-average-power, high-repetition-rate optical terahertz (THz) source based on difference frequency generation (DFG) in the GaSe crystal by using a near-degenerate 2 μm intracavity KTP optical parametric oscillator as the pump source. The power of the 2 μm dual-wavelength laser was up to 12.33 W with continuous tuning ranges of 1988.0–2196.2 nm/2278.4–2065.6 nm for two waves. Different GaSe cystal lengths have been experimentally investigated for the DFG THz source in order to optimize the THz output power, which was in good agreement with the theoretical analysis. Based on an 8 mm long GaSe crystal, the THz wave was continuously tuned from 0.21 to 3 THz. The maximum THz average power of 1.66 μW was obtained at repetition rate of 10 kHz under 1.48 THz. The single pulse energy amounted to 166 pJ and the conversion efficiency from 2 μm laser to THz output was 1.68×10−6. The signal-to-noise ratio of the detected THz voltage was 23 dB. The acceptance angle of DFG in the GaSe crystal was measured to be 0.16°.

1 March 2018 in Optics Express
Verified
Journal Article
Closed access
PDF file
JSJia Shi
Jia Shi
YWYuye Wang
Yuye Wang
TCTunan Chen
Tunan Chen
Degang XuDegang Xu
Degang Xu
HZHengli Zhao
Hengli Zhao
JYJianquan Yao
Jianquan Yao
The imaging diagnosis and prognostication of different degrees of traumatic brain injury (TBI) is very important for early care and clinical treatment. Especially, the exact recognition of mild TBI is the bottleneck for current label-free imaging technologies in neurosurgery. Here, we report an automatic evaluation method for TBI recognition with terahertz (THz) continuous-wave (CW) transmission imaging based on machine learning (ML). We propose a new feature extraction method for biological THz images combined with the transmittance distribution features in spatial domain and statistical distribution features in normalized gray histogram. Based on the extracted feature database, ML algorithms are performed for the classification of different degrees of TBI by feature selection and parameter optimization. The highest classification accuracy is up to 87.5%. The area under the curve (AUC) scores of the receiver operating characteristics (ROC) curve are all higher than 0.9, which shows this evaluation method has a good generalization ability. Furthermore, the excellent performance of the proposed system in the recognition of mild TBI is analyzed by different methodological parameters and diagnostic criteria. The system can be extensible to various diseases and will be a powerful tool in automatic biomedical diagnostics.

12 July 2019 in Biomedical Optics Express
Verified
Journal Article
Closed access
LWLimin Wu
Limin Wu
DXDegang Xu
Degang Xu
YWYuye Wang
Yuye Wang
BLBin Liao
Bin Liao
ZJZhinan Jiang
Zhinan Jiang
JYJianquan Yao
Jianquan Yao
We demonstrated that in vivo brain glioma in a mouse model using a continuous-wave terahertz reflection imaging system, as well as the ex vivo fresh brain tissues in mouse model. The tumor regions of in vivo and ex vivo brain tissues can be well distinguished by THz intensity imaging at the frequency of 2.52THz. The THz images with high sensitivity correlated well with magnetic resonance, visual and hematoxylin and eosin stained images. Furthermore, the THz spectral difference between brain gliomas and normal brain tissues were obtained in the 0.6THz to 2.8THz range, where brain gliomas have the higher refractive indices and absorption coefficients, and their differences increase particularly in the high frequency range. These results suggest that THz imaging has great potential as an alternative method for the intraoperative label-free diagnosis of brain glioma in vivo.

8 September 2017 in Journal of Lightwave Technology
Verified
Journal Article
Closed access
Jia ShiJia Shi
Jia Shi
Degang XuDegang Xu
Degang Xu
WXWei Xu
Wei Xu
YWYuye Wang
Yuye Wang
CYChao Yan
Chao Yan
Jianquan YaoJianquan Yao
Jianquan Yao
A humidity sensor based on Fabry-Perot interferometer (FPI) and intracavity sensing of a fiber ring laser is proposed and experimentally demonstrated. A compact humidity-sensitive fiber-optic FPI is developed and inserted in a fiber ring laser. Because the output power of the fiber laser is modulated by the reflection loss of the FPI at different ambient humidity, intracavity humidity sensing is induced. The experiment shows that the relative output power of the fiber laser has a good linear response to ambient humidity from 25 %RH to 95 %RH and the humidity sensitivity of 0.202 dB/%RH is obtained with a narrow 3-dB bandwidth and high signal-to-noise ratio (SNR). Furthermore, the excellent performance of the sensor for remote humidity detection is demonstrated. The sensor also shows a low temperature cross-sensitivity, fast time response, and good stability. The proposed sensor has a great potential in high-capacity sensor network and remote detections.

26 December 2017 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
YHYixin He
Yixin He
YWYuye Wang
Yuye Wang
Degang XuDegang Xu
Degang Xu
MNMeitong Nie
Meitong Nie
CYChao Yan
Chao Yan
JYJianquan Yao
Jianquan Yao

1 February 2023 in Journal of Magnesium and Alloys
Verified
Journal Article
Open access
YXYuling Xu
Yuling Xu
YHYuanding Huang
Yuanding Huang
YWYuye Wang
Yuye Wang
WGWeiming Gan
Weiming Gan
SWShiwei Wang
Shiwei Wang
Norbert HortNorbert Hort
Norbert Hort