Muhammad Ameen

Dr. Muhammad Ameen


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2020 in Processes
Verified
Journal Article
Open access
PDF file
ZYzhenjie yang
zhenjie yang
Adnan AbbasAdnan Abbas
Adnan Abbas
Wang XiaoChanWang XiaoChan
Wang XiaoChan
MAMuhammad Ameen
Muhammad Ameen
HYHaihui Yang
Haihui Yang
SSShakeel Ahmed Soomro
Shakeel Ahmed Soomro
Soil steam disinfection (SSD) technology is an effective means of eliminating soil borne diseases. Among the soil cultivation conditions of facility agriculture in the Yangtze River Delta region of China, the clay soil particles (SPs) are fine, the soil pores are small, and the texture is relatively viscous. When injection disinfection technology is applied in the clay soil, the diffusion of steam is hindered and the heating efficiency is substantially affected. To increase the heating efficiency of SSD, we first discretized the continuum model of Philip and De Vries into circular particle porous media of different sizes and random distribution. Then with Computational Fluid Dynamics (CFD) numerical simulation technology, a single-injection steam disinfection model for different SP size conditions was constructed. Furthermore, the diffusion pattern of the macro-porous vapor flow and matrix flow and the corresponding temperature field were simulated and analyzed. Finally, a single-pipe injection steam disinfection verification test was performed for different SP sizes. The test results show that for the clay soil in the Yangtze River Delta region of China, the test temperature filed results are consistent with the simulation results when the heat flow reaches H = 20 cm in the vertical direction, the simulation and test result of the heat flow in the maximum horizontal diffusion distance are L = 13 cm and 12 cm, respectively. At the same disinfection time, the simulated soil temperature change trend is consistent with the test results, and the test temperature is lower than the simulated temperature. The difference between the theoretical temperature and the experimental temperature may be attributed to the heat loss in the experimental device. Further, it is necessary to optimize the CFD simulation process and add the disintegration and deformation processes of soil particle size with the change of water content. Furthermore, the soil pores increase as the SP size increases and that a large amount of steam vertically diffuses along the macropores and accumulates on the soil surface, causing ineffective heat loss. Moreover, soil temperature distribution changes from oval (horizontal short radius/vertical long radius = 0.65) to irregular shape. As the SP size decreases, the soil pore flow path becomes fine; the steam primarily diffuses uniformly around the soil in the form of a matrix flow; the diffusion distance in the horizontal direction gradually increases; and the temperature distribution gradually becomes even, which is consistent with the soil temperature field simulation results. Similar to the energy consumption analysis, the maximum energy consumption for SP sizes>27mm and <2mm was 486and 477kJ, respectively. Therefore, proper pore growth was conducive to the diffusion of steam, but excessive pores cause steam to overflow, which increased energy consumption of the system. Considering that the test was carried out in an ideal soil environment, the rotary tiller must be increased for fine rotary tillage in an actual disinfection operation. Although large particles may appear during the rotary tillage process, an appropriate number of large particles contributes to the formation of a large pore flow, under the common effect of matrix flow, it will simultaneously promote greater steam diffusion and heating efficiency. The above theoretical research has practical guiding significance for improving the design and disinfection effect of soil steam sterilizers in the future.

11 March 2019 in Energies
Verified
Journal Article
Open access
PDF file
MAMuhammad Ameen
Muhammad Ameen
ZZZhuo Zhang
Zhuo Zhang
Wang XiaoChanWang XiaoChan
Wang XiaoChan
MYMuhammad Yaseen
Muhammad Yaseen
MUMuhammad Umair
Muhammad Umair
Muhammad Sohail MemonMuhammad Sohail Memon
Muhammad Sohail Memon
The winter season in Nanjing is from December to February, with extremely low temperature and high humidity due to seasonal snowfall. During these extreme cold climatic conditions, plants have to survive severe heat stress conditions, even if they are being kept in greenhouses. The objective of this study was to investigate a heating system that can provide heat directly to the root zone instead of heating the entire greenhouse, which is a viable option to reduce energy consumption. Root zone heating could be an effective alternative for the sustainable development of plants during the winter. A novel type of root zone heating system was applied to evaluate the energy consumption during different greenhouse ambient temperature conditions, the effects of root zone heating systems on pepper plant morphology, and heat transfer rates to plant canopy in the greenhouse. The temperature treatments in root zone heating system were T-15, T-20, T-25, T-30, and a control treatment (TC) at 15 °C, 20 °C, 25 °C, and 30 °C, respectively, while TC received no heat. A simulation study was carried out to validate the root zone temperature. The results of the current investigation revealed that energy consumption has an inverse relationship to the ambient temperature of the greenhouse, while temperature gradients to the plant canopy observed from the lower to the upper part of the plant and the upper canopy experienced less temperature fluctuation as compared to the lower part of the plant. The results also showed that treatment T-20 had the maximum in terms of the leaf dry weight, stem diameter, and the number of leaves, while T-25 showed the maximum root dry weight and stem dry weight; T-30 and T-15 had minimum dry weights of plant segments among all treatments. Control treatment (TC) showed a minimum dry mass of plant. The root zone heating with optimal root zone temperature was found to be a viable and adaptable option as this leads to improved energy consumption patterns for the sustainable growth and development of plants in greenhouses during extremely low temperatures.

10 November 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
MAMuhammad Ameen
Muhammad Ameen
Wang XiaoChanWang XiaoChan
Wang XiaoChan
MYMuhammad Yaseen
Muhammad Yaseen
MUMuhammad Umair
Muhammad Umair
KYkhurram yousaf
khurram yousaf
SSSkakeel Ahmed Soomro
Skakeel Ahmed Soomro
The proposed system was developed to help the farmers of the Yangtze River Delta to grow greenhouse plants over winter, as the region has very low winter temperatures. For this reason, the experiment was undertaken during winter in extremely low temperatures to obtain optimal results. Keeping in mind the importance of sustainable practices, the authors developed the system using sustainable materials. The system was heated for 6 hours and then the hourly heat transfer rates were measured for 12 hours. The power consumption data of the heating system during different ambient temperatures were collected. Additionally, a simulation model of the heating system was developed using the COMSOL Multiphysics 5.3a package. The heat transfer in a porous media model was used in this study. Finally, the simulation results obtained from the COMSOL Multiphysics 5.3a package were analyzed and compared to the experimental results; these results were found to be in good agreement, thus authenticating the simulation model. After analyzing the data obtained from both methods, the power consumption of the heating system during different ambient temperature conditions were also calculated, which ranged from 15.73 W to 70.02 W in the simulated method and 28.2 W to 91.2 W in the experimental method. It was found that the root zone temperature remained in the range of 0–35 °C. This range of root zone temperature is suitable for many greenhouse horticultural crops such as tomato, cucumber, pepper, strawberry, lettuce, etc. The optimal root zone temperatures of many greenhouse horticultural plants are verified by many researchers.

21 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
ZYzhenjie yang
zhenjie yang
Wang XiaoChanWang XiaoChan
Wang XiaoChan
MAMuhammad Ameen
Muhammad Ameen
Soil steam disinfection (SSD) technology is one of the effective means to eliminate soil-borne diseases, especially under the condition of clay-loam soil cultivation for facility agriculture in Yangtze River delta (China). With the fine particles, small pores and high density of the soil, the way of steam transport and heat transfer are quite different from those of other cultivation mediums, and when using SSD injection method, the diffusion of steam between pipes will be affected, inhibiting the heat transfer in the dense soil. Therefore, it is necessary to explore the influence of steam pipe spacing (SPS) on the energy consumption and soil temperature (ST) for clay-loam disinfection. The best results are to find a suitable SPS that satisfies the inter-tube steam that can be gathered together evenly without being lost to the air under limited boiler heating capacity. To this purpose, we first used a computational fluid dynamics model to calculate the effective SPS to inject steam into deep soil. Second, the ST, ST rise rate, ST coefficient of variation, and soil water content variation among different treatments (12, 18, 24, or 30 cm pipe spacing) were analysed. Finally, the heating efficiency of all treatments depending on the disinfection time ratio and relative energy consumption was evaluated. The result shows that in the clay-loam unique to Southern China, the elliptical shape of the high-temperature region obtained from the numerical simulation was basically consistent with the experiment results, and the ratios of short diameter to long diameter were 0.65 and 0.63, respectively. In the SPS = 12 and 18 cm treatments, the steam completely diffused at a 0–20 cm soil layer depth, and the heat transfer was convective. However, at an SPS = 12 cm, steam accumulation occurred at the steam pipe holes, causing excessive accumulation of steam heat. The relative energy consumptions for SPS = 30, 24, and 12 cm were above 2.18 kJ/(kg·°C), and the disinfection time ratio was below 0.8. Thus, under a two-pipe flow rate = 4–8 kg/h, the inter-tube steam was found to be completely concentrated with a uniform continuous high temperature distribution within the soil for an appropriate SPS = 18–22 cm, avoiding the unnecessary loss of steam heat, and this method can be considered for static and moving disinfection operations in the cultivated layer (−20–0 cm) of clay loam soil. However, for soil with higher clay contents, the SPS can be appropriately reduced to less than 18 cm. For soil with lower clay contents and higher sand contents, the SPS can be increased to more than 22 cm.

28 December 2018 in Sustainability
Verified
Journal Article
Open access
PDF file
RNRana Shahzad Noor
Rana Shahzad Noor
ZWzhi wang
zhi wang
MUMuhammad Umair
Muhammad Umair
MAMuhammad Ameen
Muhammad Ameen
Muhammad ImranMuhammad Imran
Muhammad Imran
YSYong Sun
Yong Sun
Water content plays a crucial role in seed development, particularly at the seed sowing stage, and it ensures good seed germination. A water seed drill was designed and developed to provide an optimum quantity of water that is required for the soil in the same furrow, right after seed placement. This soil moistening method not only improves the moisture level in the field, but it also saves a large amount of water by applying the needed water quantity in the line of sowing after seed placement. The water seed drill consisted of a wheat seed drill, a water application system, and a tank with 400 L capacity. The water seed drill yielded a 48% higher germination count than when wheat is planted through a conventional method. The data recorded also showed that the water seed drill raised the soil moisture to 24% from the existing 13% soil moisture content. The total operational cost of the water seed drill was 2.57-fold greater than the conventional seed drill, but the output cost of the water seed drill was 2.15 times (49,000 Rs/ha) more than that of the conventional seed drill.