Chris Awai Easthope

Dr. Chris Awai Easthope

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JWJiaen Wu
Jiaen Wu
KKKiran Kuruvithadam
Kiran Kuruvithadam
ASAlessandro Schaer
Alessandro Schaer
RSRichie Stoneham
Richie Stoneham
GCGeorge Chatzipirpiridis
George Chatzipirpiridis
HTHamdi Torun
Hamdi Torun
The deterioration of gait can be used as a biomarker for ageing and neurological diseases. Continuous gait monitoring and analysis are essential for early deficit detection and personalized rehabilitation. The use of mobile and wearable inertial sensor systems for gait monitoring and analysis have been well explored with promising results in the literature. However, most of these studies focus on technologies for the assessment of gait characteristics, few of them have considered the data acquisition bandwidth of the sensing system. Inadequate sampling frequency will sacrifice signal fidelity, thus leading to an inaccurate estimation especially for spatial gait parameters. In this work, we developed an inertial sensor based in-shoe gait analysis system for real-time gait monitoring and investigated the optimal sampling frequency to capture all the information on walking patterns. An exploratory validation study was performed using an optical motion capture system on four healthy adult subjects, where each person underwent five walking sessions, giving a total of 20 sessions. Percentage mean absolute errors (MAE%) obtained in stride time, stride length, stride velocity, and cadence while walking were 1.19%, 1.68%, 2.08%, and 1.23%, respectively. In addition, an eigenanalysis based graphical descriptor from raw gait cycle signals was proposed as a new gait metric that can be quantified by principal component analysis to differentiate gait patterns, which has great potential to be used as a powerful analytical tool for gait disorder diagnostics.

4 September 2025 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
TUTim Unger
Tim Unger
AMArash Sal Moslehian
Arash Sal Moslehian
JPJ.D. Peiffer
J.D. Peiffer
JUJohann Ullrich
Johann Ullrich
RGRoger Gassert
Roger Gassert
CEChris Awai Easthope
Chris Awai Easthope
Marker-based Optical Motion Capture (OMC) paired with biomechanical modeling is currently considered the most precise and accurate method for measuring human movement kinematics. However, combining differentiable biomechanical modeling with Markerless Motion Capture (MMC) offers a promising approach to motion capture in clinical settings, requiring only minimal equipment, such as webcams, and minimal effort for data collection. This study compares key kinematic outcomes from biomechanically modeled MMC and OMC data in 15 individuals with stroke performing the drinking task, a functional task recommended for assessing upper limb movement quality. We observed a high level of agreement in kinematic trajectories between MMC and OMC, as indicated by high correlations (median r > 0.95 for the majority of kinematic trajectories) and median RMSE (root mean squared error) values ranging from 2∘-5∘ for joint angles, 0.04 m/s for end-effector velocity, and 6mm for trunk displacement. Trial-to-trial biases between OMC and MMC were consistent within participant sessions, with interquartile ranges of bias around 1-3∘ for joint angles, 0.01m/s in end-effector velocity, and approximately 3mm for trunk displacement. Our findings indicate that our MMC for arm tracking is approaching the accuracy of marker-based methods, supporting its potential for use in clinical settings. MMC could provide valuable insights into movement rehabilitation after stroke, potentially enhancing the effectiveness of rehabilitation strategies.

5 January 2023 in Sensors
Verified
Journal Article
Open access
PDF file
ASAnne Schwarz
Anne Schwarz
AHAdib Al-Haj Husain
Adib Al-Haj Husain
LELorenzo Einaudi
Lorenzo Einaudi
ETEva Thürlimann
Eva Thürlimann
JLJulia Läderach
Julia Läderach
ALAndreas Luft
Andreas Luft
The restoration of gait and mobility after stroke is an important and challenging therapy goal due to the complexity of the potentially impaired functions. As a result, precise and clinically feasible assessment methods are required for personalized gait rehabilitation after stroke. The aim of this study is to investigate the reliability and validity of a sensor-based gait analysis system in stroke survivors with different severities of gait deficits. For this purpose, 28 chronic stroke survivors (9 women, ages: 62.04 ± 11.68 years) with mild to moderate walking impairments performed a set of ambulatory assessments (3× 10MWT, 1× 6MWT per session) twice while being equipped with a sensor suit. The derived gait reports provided information about speed, step length, step width, swing and stance phases, as well as joint angles of the hip, knee, and ankle, which we analyzed for test-retest reliability and hypothesis testing. Further, test-retest reliability resulted in a mean ICC of 0.78 (range: 0.46–0.88) for walking 10 m and a mean ICC of 0.90 (range: 0.63–0.99) for walking 6 min. Additionally, all gait parameters showed moderate-to-strong correlations with clinical scales reflecting lower limb function. These results support the applicability of this sensor-based gait analysis system for individuals with stroke-related walking impairments.

6 November 2021 in Sensors
Verified
Journal Article
Open access
PDF file
CWCharlotte Werner
Charlotte Werner
CEChris Awai Easthope
Chris Awai Easthope
ACArmin Curt
Armin Curt
László DemkóLászló Demkó
László Demkó
Spinal cord injury (SCI) patients suffer from diverse gait deficits depending on the severity of their injury. Gait assessments can objectively track the progress during rehabilitation and support clinical decision making, but a comprehensive gait analysis requires far more complex setups and time-consuming protocols that are not feasible in the daily clinical routine. As using inertial sensors for mobile gait analysis has started to gain ground, this work aimed to develop a sensor-based gait analysis for the specific population of SCI patients that measures the spatio-temporal parameters of typical gait laboratories for day-to-day clinical applications. The proposed algorithm uses shank-mounted inertial sensors and personalized thresholds to detect steps and gait events according to the individual gait profiles. The method was validated in nine SCI patients and 17 healthy controls walking on an instrumented treadmill while wearing reflective markers for motion capture used as a gold standard. The sensor-based algorithm (i) performed similarly well for the two cohorts and (ii) is robust enough to cover the diverse gait deficits of SCI patients, from slow (0.3 m/s) to preferred walking speeds.

23 December 2019 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
MBM. Bannwart
M. Bannwart
ERE. Rohland
E. Rohland
CEChris Awai Easthope
Chris Awai Easthope
GRGeorg Rauter
Georg Rauter
MBMarc Bolliger
Marc Bolliger
Background: After a neurological injury, mobility focused rehabilitation programs intensively train walking on treadmills or overground. However, after discharge, quite a few patients are not able to independently negotiate stairs, a real-world task with high physical and psychological demands and a high injury risk. To decrease fall risk and improve patients’ capacity to navigate typical environments, early stair negotiation training can help restore competence and confidence in safe stair negotiation. One way to enable early training in a safe and permissive environment is to unload the patient with a body weight support system. We here investigated if unloaded stair negotiation complies with basic locomotor principles, in terms of enabling performance of a physiological movement pattern with minimal compensation.Methods: Seventeen able-bodied participants were unloaded with 0–50% bodyweight during self-paced ascent and descent of a 4-tread staircase. Spatio-temporal parameters, joint ranges of motion, ground reaction forces and myoelectric activity in the main lower limb muscles of participants were compared between unloading levels. Likelihood ratio tests of separated linear mixed models of the investigated outcomes assessed if unloading affects the parameters in general. Subsequent post-hoc testing revealed which levels of unloading differed from unsupported stair negotiation.Results: Unloading affected walking velocity, joint ranges of motion, vertical ground reaction force parameters and myoelectric activity in all investigated muscles for stair ascent and descent while step width and single support duration were only affected during ascent. A reduction with increasing levels of body weight support was seen in walking velocity (0.07–0.12 m/s), ranges of motion of the knee and hip (2–10°), vertical ground reaction force peaks (10–70%) and myoelectric activity (17–70%). An increase with unloading was only seen during ascent for ankle range of motion and tibialis anterior activity at substantial unloading.Conclusions: Body weight support facilitates stair negotiation by providing safety and support against gravity. Although unloading effects are present in most parameters, up to 30% body weight support these changes are small, and no dysfunctional patterns are introduced. Body weight support therefore fulfills all the necessary requirements for early stair negotiation training.

21 December 2024 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
LMLaura Mayrhuber
Laura Mayrhuber
SASebastian D. Andres
Sebastian D. Andres
MLMathilde L. Legrand
Mathilde L. Legrand
ALAndreas R. Luft
Andreas R. Luft
FRFranziska Ryser
Franziska Ryser
OLOlivier Lambercy
Olivier Lambercy
Upper limb impairment post-stroke often leads to a predominant use of the less affected arm and consequent learned disuse of the affected side, hindering upper limb outcome. Wearable sensors such as accelerometers, combined with smart reminders (i.e., based on the amount of arm activity), offer a potential approach to promote increased use of the affected arm to improve upper limb use during daily life. This study aimed to evaluate the efficacy of wrist vibratory reminders during a six-week home-based intervention in chronic stroke survivors. We evaluated the impact of the home-based intervention on the primary outcome, the Motor Activity Log-14 Item Version scores Amount of Use (MAL-14 AOU), and the secondary outcomes MAL-14 Quality of Movement (QOM) and sensor-derived activity metrics from the affected arm. A randomized controlled trial design was used for the study: the intervention group received personalized reminders based on individualized arm activity goals, while the control group did not receive any feedback. Mixed linear models assessed the influence of the group, week of the intervention period, and initial impairment level on MAL-14 and arm activity metrics. Forty-two participants were enrolled in the study. Overall, participants exhibited modest but not clinically relevant increases in MAL-14 AOU (+ 0.2 points) and QOM (+ 0.2 points) after the intervention period, with no statistically significant differences between the intervention and control group. Feasibility challenges were noted, such as adherence to wearing the trackers and sensor data quality. However, in participants with sufficiently available sensor data (n = 23), the affected arm use extracted from the sensor data was significantly higher in the intervention group (p < 0.05). The initial impairment level strongly influenced affected arm use and both MAL-14 AOU and QOM (p < 0.01). The study investigated the effectiveness of incorporating activity trackers with smart reminders to increase affected arm activity among stroke survivors during daily life. While the results regarding the increased arm use at home are promising, patient-reported outcomes remained below clinically meaningful thresholds and showed no group differences. Further, it is essential to acknowledge feasibility issues such as adherence to wearing the trackers during the intervention and missing sensor data. NCT03294187.