Peter Horan

Mr. Peter Horan

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 August 2021 in Buildings
Verified
Journal Article
Open access
PDF file
ZWZheng Wang
Zheng Wang
Mark LutherMark Luther
Mark Luther
MAMehdi Amirkhani
Mehdi Amirkhani
Chunlu LiuChunlu Liu
Chunlu Liu
PHPeter Horan
Peter Horan
Heat Pumps are becoming one of the most considered mechanical conditioning equipment in our buildings. While they are popular, there appears to be quite a vast range of system types and applications in building conditioning. This paper primarily reviews the literature on heat pumps, the various types, and the consideration of design end uses. The fact that there are different energy sources for heat pumps is considered, as well as the different sinks in which energy is stored or dissipated. It is evident that advanced heat pump systems cater well to the use of renewable energy resources. Therefore, in the move towards net-zero energy building operation, the correct selection of a heat pump can help to increase self-consumption of solar PV generation and even make use of direct solar energy heating. This paper reviews the technologies for heat pump selection, application, and design for residential buildings.

2 September 2021 in Energies
Verified
Journal Article
Open access
PDF file
TSThomas Simko
Thomas Simko
Mark LutherMark Luther
Mark Luther
HLHong Xian Li
Hong Xian Li
PHPeter Horan
Peter Horan
Innovative mechanical services coupled with renewable energy systems are crucial for achieving a net zero energy goal for houses. Conventional systems tend to be vastly oversized because they lack the means to buffer energy flows and are based on peak loads. This paper presents an approach to achieve a net zero energy goal for houses by using a solar PV system, heat pumps, and thermal and electrical storage batteries, all off-the-shelf. Constraining one part of the system and then showing how to manage energy storage and flow is a paradigm shift in sizing. The design is for a modest-sized house built in Melbourne, Australia. The output of a solar photovoltaic array drives a small-scale heat pump to heat water, buffering its energy in a thermal battery to energise a radiant space heating system. Space cooling is provided by a separate heat pump. Through energy storage in electrical and thermal batteries, it is possible to meet the electricity, heating and cooling needs of the house for the Melbourne climate with a heat pump that draws less than 1 kW. The design methodology is detailed in an appendix and can be applied to similar projects. This paper contributes to similar work worldwide that aims to reinforce innovative renewable energy driven service design.

1 June 2018 in Energy and Buildings
Verified
Journal Article
Closed access
Mark LutherMark Luther
Mark Luther
PHPeter Horan
Peter Horan
OTOlubukola Tokede
Olubukola Tokede

14 January 2024 in Journal of Building Engineering
Verified
Journal Article
Open access
ZWZheng Wang
Zheng Wang
Mark LutherMark Luther
Mark Luther
PHPeter Horan
Peter Horan
JMJane Matthews
Jane Matthews
Chunlu LiuChunlu Liu
Chunlu Liu

6 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
PHPeter Horan
Peter Horan
Mark LutherMark Luther
Mark Luther
HLHong Xian Li
Hong Xian Li
The purpose of this paper is to examine several real house cases as renewable energy resources are installed. It is an empirical study, based on first principles applied to measured data. In the first case presented, a PV solar system has been installed and a hybrid vehicle purchased. Battery storage is being considered. Smart Meter data (provided in Victoria, Australia) measures the electrical energy flowing to and from the grid in each half hour. Missing is the story about what the house is generating and what its energy requirements are through each half hour interval. We apply actual (on site) solar PV data to this study, resolving the unknown energy flows. Analysing energy flow has revealed that there are five fundamental quantities which determine performance, namely energy load, energy import, energy harvesting, energy export and energy storage. As a function of PV size these quantities depend on four parameters, easily derivable from the Smart Meter data, namely the house load, the night-time house load (no PV generation), the rating of the solar PV system and the tariffs charged. This reveals most of the information for providing advice on PV array size and whether to install a battery. An important discovery is that a battery, no matter what size, needs a PV system large enough to charge it during the winter months. The analysis is extended to two more houses located within 5 km for which detailed solar data is unavailable.

5 August 2023
Verified
Book Chapter
Closed access
PDF file
ZWZheng Wang
Zheng Wang
Mark LutherMark Luther
Mark Luther
PHPeter Horan
Peter Horan
JMJane Matthews
Jane Matthews
Chunlu LiuChunlu Liu
Chunlu Liu