Matthew Pearson

Dr. Matthew Pearson


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2015 in Composites Part B: Engineering
Verified
Journal Article
Open access
JMJohn McCrory
John McCrory
Safaa Kh Al-jumailiSafaa Kh Al-jumaili
Safaa Kh Al-jumaili
DCDavide Crivelli
Davide Crivelli
MPMatthew Pearson
Matthew Pearson
Mark EatonMark Eaton
Mark Eaton
RPRhys Pullin
Rhys Pullin
Classifying the type of damage occurring within a structure using a structural health monitoring system can allow the end user to assess what kind of repairs, if any, that a component requires. This paper investigates the use of acoustic emission (AE) to locate and classify the type of damage occurring in a composite, carbon fibre panel during buckling. The damage was first located using a bespoke location algorithm developed at Cardiff University, called delta-T mapping. Signals identified as coming from the regions of damage were then analysed using three AE classification techniques; Artificial Neural Network (ANN) analysis, Unsupervised Waveform Clustering (UWC) and corrected Measured Amplitude Ratio (MAR). A comparison of results yielded by these techniques shows a strong agreement regarding the nature of the damage present in the panel, with the signals assigned to two different damage mechanisms, believed to be delamination and matrix cracking. Ultrasonic C-scan images and a digital image correlation (DIC) analysis of the buckled panel were used as validation. MAR’s ability to reveal the orientation of recorded signals greatly assisted the identification of the delamination region, however, ANN and UWC have the ability to group signals into several different classes, which would prove useful in instances where several damage mechanisms were generated. Combining each technique’s individual merits in a multi-technique analysis dramatically improved the reliability of the AE investigation and it is thought that this cross-correlation between techniques will also be the key to developing a reliable SHM system

1 May 2016 in Mechanical Systems and Signal Processing
Verified
Journal Article
Open access
Safaa Kh Al-jumailiSafaa Kh Al-jumaili
Safaa Kh Al-jumaili
MPMatthew Pearson
Matthew Pearson
KHKaren M. Holford
Karen M. Holford
MEMark J. Eaton
Mark J. Eaton
RPRhys Pullin
Rhys Pullin

7 October 2016 in Structural Health Monitoring
Verified
Journal Article
Open access
MPMatthew Pearson
Matthew Pearson
MEMark Eaton
Mark Eaton
CFCarol Featherston
Carol Featherston
RPRhys Pullin
Rhys Pullin
KHKaren Holford
Karen Holford
In order to overcome the difficulties in applying traditional time-of-arrival techniques for locating acoustic emission events in complex structures and materials, a technique termed ‘Delta-t mapping’ was developed. This article presents a significant improvement on this, in which the difficulties in identifying the precise arrival time of an acoustic emission signal are addressed by incorporating the Akaike information criteria. The performance of the time of arrival, the Delta-t mapping and the Akaike information criteria Delta-t mapping techniques is assessed by locating artificial acoustic emission sources, fatigue damage and impact events in aluminium and composite materials, respectively. For all investigations conducted, the improved Akaike information criteria Delta-t technique shows a reduction in average Euclidean source location error irrespective of material or source type. For locating Hsu–Nielsen sources on a complex aluminium specimen, the average source location error (Euclidean) is 32.6 (time of arrival), 5.8 (Delta-t) and 3 mm (Akaike information criteria Delta-t). For locating fatigue damage on the same specimen, the average error is 20.2 (time of arrival), 4.2 (Delta-t) and 3.4 mm (Akaike information criteria Delta-t). For locating Hsu–Nielsen sources on a composite panel, the average error is 19.3 (time of arrival), 18.9 (Delta-t) and 4.2 mm (Akaike information criteria Delta-t). Finally, the Akaike information criteria Delta-t mapping technique had the lowest average error (3.3 mm) when locating impact events when compared with the Delta-t (18.9 mm) and time of arrival (124.7 mm) techniques. Overall, the Akaike information criteria Delta-t mapping technique is the only technique which demonstrates consistently the lowest average source location error (greatest average error of 4.2 mm) when compared with the Delta-t (greatest average error of 18.9 mm) and time of arrival (greatest average error of 124.7 mm) techniques. These results demonstrate that the Akaike information criteria Delta-t mapping technique is a viable option for acoustic emission source location, increasing the accuracy and likelihood of damage detection, irrespective of material, geometry and source type.

1 June 2015 in Composites Part B: Engineering
Verified
Journal Article
Closed access
DCDavide Crivelli
Davide Crivelli
MGMARIO GUAGLIANO
MARIO GUAGLIANO
Mark EatonMark Eaton
Mark Eaton
MPMatthew Pearson
Matthew Pearson
SASafaa Al-Jumaili
Safaa Al-Jumaili
RPRhys Pullin
Rhys Pullin

16 September 2013 in Physical Review Letters
Verified
Journal Article
Closed access
AVAnnika Voss
Annika Voss
MPMatthew Pearson
Matthew Pearson
JBJonathan Billowes
Jonathan Billowes
FBFritz Buchinger
Fritz Buchinger
BCBradley Cheal
Bradley Cheal
OSOlivier Shelbaya
Olivier Shelbaya
Collinear laser spectroscopy was performed on the nuclear ground states of the neutron-deficient isotopes $^{206,205,204}\mathrm{Fr}$. A new technique was developed to suppress hyperfine pumping in collinear laser spectroscopy of atoms. This involved high-frequency intensity modulation of narrow-linewidth laser light using fast-switching electro-optical modulators. The nuclear ground-state spins of $^{206,205,204}\mathrm{Fr}$ were determined to be 3, $9/2$, and 3, respectively. Both the changes in mean-squared charge radii and nuclear magnetic dipole moments indicate a departure from single-particle estimates.

24 December 2014 in Structural Health Monitoring
Verified
Journal Article
Closed access
Safaa Kh Al-jumailiSafaa Kh Al-jumaili
Safaa Kh Al-jumaili
KHKaren M Holford
Karen M Holford
Mark EatonMark Eaton
Mark Eaton
JMJohn McCrory
John McCrory
MPMatthew Pearson
Matthew Pearson
RPRhys Pullin
Rhys Pullin
Acoustic emission is widely used for mechanical diagnostics and to characterise damage in composite materials. Distinction between different damage mechanisms is still one of the major challenges and remains an unresolved issue. The objective of cluster analysis is to separate an acoustic emission data set into multiple classes that reflect different acoustic emission sources. This article is concerned with the implementation of unsupervised clustering techniques to classify acoustic emission transients from a carbon fibre laminate buckling test. A new approach to signal feature extraction was utilised, whereby principal components provide signal features that represent the greatest data variance while remaining linearly uncorrelated with each other; feature selection was undertaken using a hierarchical clustering method and finally a cluster analysis was performed using k-means and Fuzzy C-means techniques. The aim of the work is to reduce the data required in the classification process, thereby reducing the processing time and computational power required, without significantly affecting the classification result. Thus, an approach which is more suited to online processing, allowing fast and efficient processing and storage of data is provided. The proposed unsupervised clustering analysis was able to separate acoustic emission signals into two different clusters that were correlated to the damage mechanisms observed. The results show that the clustering groups have a good fit with ultrasonic C-scan and digital image correlation strain data. The application of a clustering process that uses the most effective acoustic emission features as input data is an objective method, and this investigation shows that it may be a useful complement in the field of non-destructive evaluation.