Balint Molnar

Dr. Balint Molnar

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 November 2021 in Bioactive Materials
Verified
Journal Article
Open access
Patrick RiderPatrick Rider
Patrick Rider
ŽKŽeljka Perić Kačarević
Željka Perić Kačarević
AEAkiva Elad
Akiva Elad
DTDrazen Tadic
Drazen Tadic
DRDaniel Rothamel
Daniel Rothamel
FWFrank Witte
Frank Witte
Barrier membranes are commonly used as part of the dental surgical technique guided bone regeneration (GBR) and are often made of resorbable collagen or non-resorbable materials such as PTFE. While collagen membranes do not provide sufficient mechanical protection of the covered bone defect, titanium reinforced membranes and non-resorbable membranes need to be removed in a second surgery. Thus, biodegradable GBR membranes made of pure magnesium might be an alternative. In this study a biodegradable pure magnesium (99.95%) membrane has been proven to have all of the necessary requirements for an optimal regenerative outcome from both a mechanical and biological perspective. After implantation, the magnesium membrane separates the regenerating bone from the overlying, faster proliferating soft tissue. During the initial healing period, the membrane maintained a barrier function and space provision, whilst retaining the positioning of the bone graft material within the defect space. As the magnesium metal corroded, it formed a salty corrosion layer and local gas cavities, both of which extended the functional lifespan of the membrane barrier capabilities. During the resorption of the magnesium metal and magnesium salts, it was observed that the membrane became surrounded and then replaced by new bone. After the membrane had completely resorbed, only healthy tissue remained. The in vivo performance study demonstrated that the magnesium membrane has a comparable healing response and tissue regeneration to that of a resorbable collagen membrane. Overall, the magnesium membrane demonstrated all of the ideal qualities for a barrier membrane used in GBR treatment.

2 December 2021 in Bioactive Materials
Verified
Journal Article
Open access
ŽKŽeljka Perić Kačarević
Željka Perić Kačarević
Patrick RiderPatrick Rider
Patrick Rider
AEAkiva Elad
Akiva Elad
DTDrazen Tadic
Drazen Tadic
DRDaniel Rothamel
Daniel Rothamel
FWFrank Witte
Frank Witte
An ideal fixation system for guided bone (GBR) regeneration in oral surgery must fulfil several criteria that includes the provision of adequate mechanical fixation, complete resorption when no longer needed, complete replacement by bone, as well as be biocompatible and have a good clinical manageability. For the first time, a biodegradable magnesium fixation screw made of the magnesium alloy WZM211 with a MgF2 coating has been designed and tested to fulfill these criteria. Adequate mechanical fixation was shown for the magnesium fixation screw in several benchtop tests that directly compared the magnesium fixation screw with an equivalent polymeric resorbable device. Results demonstrated slightly superior mechanical properties of the magnesium device in comparison to the polymeric device even after 4 weeks of degradation. Biocompatibility of the magnesium fixation screw was demonstrated in several in vitro and in vivo tests. Degradation of the magnesium screw was investigated in in vitro and in vivo tests, where it was found that the screw is resorbed slowly and completely after 52 weeks, providing adequate fixation in the early critical healing phase. Overall, the magnesium fixation screw demonstrates all of the key properties required for an ideal fixation screw of membranes used in guided bone regeneration (GBR) surgeries.

25 April 2022 in Materials
Verified
Journal Article
Open access
PDF file
Patrick RiderPatrick Rider
Patrick Rider
Zeljka Peric KacarevicZeljka Peric Kacarevic
Zeljka Peric Kacarevic
AEAkiva Elad
Akiva Elad
DRDaniel Rothamel
Daniel Rothamel
GSGerrit Sauer
Gerrit Sauer
FWFrank Witte
Frank Witte
For the surgical technique of guided bone regeneration (GBR), the choice of available barrier membranes has until recently not included an option that is mechanically strong, durable, synthetic and resorbable. The most commonly used resorbable membranes are made from collagen, which are restricted in their mechanical strength. The purpose of this study is to evaluate the degradation and regeneration potential of a magnesium membrane compared to a collagen membrane. In eighteen beagle dogs, experimental bone defects were filled with bovine xenograft and covered with either a magnesium membrane or collagen membrane. The health status of the animals was regularly monitored and recorded. Following sacrifice, the hemimandibles were prepared for micro-CT (μ-CT) analysis. Complications during healing were observed in both groups, but ultimately, the regenerative outcome was similar between groups. The μ-CT parameters showed comparable results in both groups in terms of new bone formation at all four time points. In addition, the μ-CT analysis showed that the greatest degradation of the magnesium membranes occurred between 1 and 8 weeks and continued until week 16. The proportion of new bone within the defect site was similar for both treatment groups, indicating the potential for the magnesium membrane to be used as a viable alternative to collagen membranes. Overall, the new magnesium membrane is a functional and safe membrane for the treatment of defects according to the principles of GBR.

19 April 2023 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
ESEleonora Solyom
Eleonora Solyom
ESEszter Ágnes Szalai
Eszter Ágnes Szalai
LCLászló Márk Czumbel
László Márk Czumbel
BSBence Szabó
Bence Szabó
SVSzilárd Váncsa
Szilárd Váncsa
RFReka Fazekas
Reka Fazekas
Background: Ridge resorption following tooth extraction may be reduced by alveolar ridge preservation (ARP). Previous randomized clinical trials and systematic reviews have suggested that autogenous tooth bone graft (ATB) can be an effective alternative material for ARP. However, the results are heterogeneous. Therefore, our research aimed to evaluate the efficacy of ATB in ARP. Methods: A systematic search was conducted in Cochrane Library, Embase, MEDLINE and Scopus for studies published from inception to 31 November 2021. We searched searched for randomized, non-randomized controlled trials and case series reporting on ATB use for ARP. The primary outcome was the ridge width difference pre- and post-surgery, measured in millimetres (mm) measured on CBCT (cone beam computed tomography). The secondary outcomes were the histological results. We followed the PRISMA2020 recommendations for reporting our systematic review and meta-analysis. Results: The analysis included eight studies for the primary and six for the secondary outcomes. The meta-analysis revealed a positive ridge preservation effect with a pooled mean difference ridge width change of -0.72 mm. The pooled mean residual graft proportion was 11.61%, and the newly formed bone proportion was 40.23%. The pooled mean of newly formed bone proportion was higher in the group where ATB originated from both the root and crown of the tooth. Conclusions: ATB is an effective particulate graft material in ARP. Complete demineralization of the ATB tends to decrease the proportion of newly formed bone. ATB can be an attractive option for ARP. Trial registration: The study protocol was registered on PROSPERO (CRD42021287890).

9 June 2022 in Materials
Verified
Journal Article
Open access
PDF file
Patrick RiderPatrick Rider
Patrick Rider
Zeljka Peric KacarevicZeljka Peric Kacarevic
Zeljka Peric Kacarevic
AEAkiva Elad
Akiva Elad
DRDaniel Rothamel
Daniel Rothamel
GSGerrit Sauer
Gerrit Sauer
FWFrank Witte
Frank Witte
Nowadays, the most commonly used fixation systems are non-resorbable, but new resorbable magnesium alloy fixation screws have been introduced recently. Therefore, the aim of this study was to compare the magnesium fixation screw and the commonly used non-resorbable titanium screw in an animal model. Four 3-wall defect sites were covered with collagen membranes in the mandible of twenty beagle dogs (two sites on the left and two on the right). Each membrane was fixed with either four magnesium screws or four titanium screws. Post-operative follow-up revealed the expected observations such as transient inflammation and pain. Both groups showed a good healing response, with no differences between groups. Micro-CT analysis showed no significant difference between groups in terms of BV/TV or soft tissue volume. The void volume in the magnesium fixation screw group continued to decrease on average between the different timepoints, but not significantly. Furthermore, a gradual progression of the degradation process of the magnesium screws was observed in the same group. Magnesium screws and titanium screws showed equal performance in tissue regeneration according to GBR principles. An additional advantage of magnesium screws is their resorbable nature, which eliminates the need for a second surgical step to remove the screws.

16 August 2021 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
KOKristof Orban
Kristof Orban
EVEndre Varga
Endre Varga
PWPéter Windisch
Péter Windisch
GBGábor Braunitzer
Gábor Braunitzer
BMBalint Molnar
Balint Molnar
Objectives: To compare the accuracy of implant placement performed with either a surgical motor or a torque wrench as part of a half-guided surgical protocol. Materials and methods: Implant insertion with half-guided surgical protocol was utilized by surgical motor (machine-driven group) or torque wrench (manual group) in the posterior maxilla. After the healing period, accuracy comparison between planned and actual implant positions was performed based on preoperative cone beam computed tomography and postoperative digital intraoral scans. Coronal, apical, and angular deviations, insertion time, and insertion torque were evaluated. Results: Forty patients were treated with 1 implant each; 20 implants were inserted with a surgical motor and 20 implants with a torque wrench. Global coronal and apical deviations were 1.20 ± 0.46 mm and 1.45 ± 0.79 mm in the machine-driven group, and 1.13 ± 0.38 mm and 1.18 ± 0.28 mm in the manual group (respectively). The mean angular deviation was 4.82 ± 2.07° in the machine-driven group and 4.11 ± 1.63° in the manual group. Mean insertion torque was 21.75 ± 9.75 Ncm in the machine-driven group, compared to 18.75 ± 7.05 Ncm in the manual group. Implant placement duration was 9.25 ± 1.86 s in the machine-driven group at a speed of 50 rpm, and 36.40 ± 8.15 s in the manual group. Conclusion: No significant difference was found between the two groups in terms of accuracy and mean insertion torque, while machine-driven implant placement was significantly less time-consuming. Clinical relevance: Optimal implant placement accuracy utilized by half-guided surgical protocol can be achieved with both machine-driven and torque wrench insertion. Trial registration: ID: NCT04854239