Different studies demonstrated the possibility to produce TiO2 nanotubes (TNTs) on Ti6Al4V alloy by electrochemical anodization. However, the anodizing behavior of α and β-phases in organic electrolytes is not yet clarified. This study reports on the anodizing behavior of the two phases in an ethylene glycol electrolyte using different applied potentials and anodizing times. Atomic force and scanning electron microscopies were used to highlight the anodic oxides differences in morphology. It was demonstrated that the initial compact oxide grew faster over the β-phase as the higher Al content of the α-phase caused its re-passivation, and the higher solubility of the V-rich oxide led to earlier pores formation over the β-phase. The trend was inverted once the pores formed over the compact oxide of the α-phase. The growth rate of the α-phase TNTs was higher than that of the β-phase ones, leading to the formation of long and well defined nanotubes with thin walls and a honeycomb tubular structure, while the ones grown over the β-phase were individual, shorter, and with thicker walls.
Anodic oxidation of CP-Ti, for production of TiO2 nanotubes, has been extensively described in terms of the electrochemical mechanism of tubular growth or the effect of the parameters on the final tube morphology. Recently, a kinetic growth model was proposed to describe the distinct morphologies of the anodic oxide layer as phases of the nanotubular development process, offering a new perspective for the tuning of nanotube production. In this work, the anodizing behavior of a CP-Ti alloy in an ethylene glycol electrolyte was investigated in light of this new model. The final morphology of the nanotubes was characterized by SEM, considering the effects of electrolyte aging, the microstructure, the applied potential difference and time on the morphological development of nanotubes. Electrolyte aging was shown to lead to a decreased dissolution effect on the oxide. The applied potential difference was shown to lead to an increased dissolution effect and more rapid nanotube growth kinetics, while time resulted in extended dissolution. Moreover, the obtained results were analyzed considering a previous study focused on the anodizing behavior of the α- and β-phases of Ti6Al4V alloy. Overall, the tube morphology resembled that obtained for the Al-containing α-phase of the Ti6Al4V alloy, but the growth kinetics were considerably slower on CP-Ti.
1 July 2021 in Journal of the Electrochemical Society
Thin films of alumina and hafnia were prepared by atomic layer deposition, with the aim of investigating the use of such films in biomedical applications. Films were deposited on commercially pure titanium and on medical stainless steel. Two configurations were prepared: single alumina films, 20 nm and 60 nm thick, and a multilayer film, 60 nm thick, consisting of alumina/hafnia/alumina layers, each 20 nm thick. The morphology, structure and composition of the coated alloys were characterized using scanning electron microscopy with energy-dispersive X-ray spectroscopy and X-ray photoelectron spectroscopy. In addition, ellipsometry and atomic force microscopy coupled with scanning Kelvin probe force microscopy, were used to study the thickness and the topography with surface potential properties. An improvised method, involving the Vickers hardness test, was applied to assess the delamination of the deposited films. Coated specimens, as well as bare substrates, were tested at 37 °C in simulated body fluid, using potentiodynamic polarization and electrochemical impedance spectroscopy as techniques for assessing corrosion susceptibility. In general, single and multilayer thin films possess excellent barrier properties and are worth investigating further for biomedical applications. The degree of protection is dependent mainly on film thickness and on the type of substrate, and less on configuration.
Surface modification of the Ti6Al4V alloy (ASTM grade 5), with the fabrication of vertically oriented TiO2 nanotubes, has been receiving increasing attention both as a way to provide advanced bioactive features and the ability to act as reservoirs for a localized, controlled drug release. In this work, TiO2 nanotubes were grown on the surface of a Ti6Al4V alloy through electrochemical anodization. An ethylene glycol-based electrolyte containing 0.5 wt.% NH4F and 2.5% (v/v) H2O was used. Post-anodizing heat treatments at 500 °C in air atmosphere were performed to achieve a crystalline oxide layer with a higher mechanical stability. Following these treatments, Zn or Cu nanoparticles were incorporated into the nanotubular structures through electrodeposition processes. Then, the antimicrobial performance of the obtained surfaces was assessed against Staphylococcus epidermidis, a Gram-positive bacterium common in implant-related infections. Lastly, the cytotoxicity of the produced surface was evaluated against MC3T3-E1 mouse pre-osteoblast cells. In general, Cu-doped TiO2 nanotubes presented an almost total antimicrobial action, while Zn doped samples had a lower, but still significant antibacterial effect. However, a highly cytotoxic effect against MC3T3-E1 cells was observed on all anodized samples due to the release of vanadium from the alloy. In spite of this, the surface modification reported in this work can be a valid solution for existing commercially available orthopedic implants, considering that similar solutions were already studied in in vivo assays.
This work focuses on the production of electrodeposited nickel matrix composite coatings containing Ti nanoparticles and on the modification of the process parameters in order to maximise the codeposited particles content as well as obtaining a uniform distribution along the coating thickness. The deposition was carried out using a Ni sulphamate plating bath with different amounts of Ti nanoparticles. The plating parameters such as current density, current type (direct, DC, or pulsed, PC) and the use of ultrasound during the deposition have been modified. The specimens produced have had their microstructure, chemical composition and microhardness analysed. It was found that the increase of the particle concentration in the plating bath up to 40 g L−1 leads to an increase of the amount of codeposited particles. The use of ultrasound prevents agglomeration of the particles, leads to a more uniform distribution and increases the Ti content. However, it induces microstructural defects in the matrix. These defects can be limited by increasing the current density or by using pulsed current.