Martin Siegel

Dr. Martin Siegel

BSS Hochspannungstechnik GmbH, Sindelfingen, Baden-Württemberg, Germany
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2016 in Energies
Verified
Journal Article
Open access
PDF file
STStefan Tenbohlen
Stefan Tenbohlen
SCSebastian Coenen
Sebastian Coenen
MDMohammad Djamali
Mohammad Djamali
AMAndreas Müller
Andreas Müller
MSMohammad Hamed Samimi
Mohammad Hamed Samimi
Martin SiegelMartin Siegel
Martin Siegel
With the increasing age of the primary equipment of the electrical grids there exists also an increasing need to know its internal condition. For this purpose, off- and online diagnostic methods and systems for power transformers have been developed in recent years. Online monitoring is used continuously during operation and offers possibilities to record the relevant stresses which can affect the lifetime. The evaluation of these data offers the possibility of detecting oncoming faults early. In comparison to this, offline methods require disconnecting the transformer from the electrical grid and are used during planned inspections or when the transformer is already failure suspicious. This contribution presents the status and current trends of different diagnostic techniques of power transformers. It provides significant tutorial elements, backed up by case studies, results and some analysis. The broadness and improvements of the presented diagnostic techniques show that the power transformer is not anymore a black box that does not allow a view into its internal condition. Reliable and accurate condition assessment is possible leading to more efficient maintenance strategies.

7 March 2017 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Martin SiegelMartin Siegel
Martin Siegel
MBMichael Beltle
Michael Beltle
STStefan Tenbohlen
Stefan Tenbohlen
SCSebastian Coenen
Sebastian Coenen
The reliability of electrical energy networks depends on both, the quality and reliability of its electrical equipment, e.g. power transformers. Local failures inside their insulation may lead to breakdowns and hence to high outage and penalty costs. Power transformers can be tested on partial discharge (PD) activity before commissioning and monitored during service in order to prevent these events. In the first part, this contribution presents different types of ultra-high frequency (UHF) sensors for PD measurement. Various applications of UHF sensors and proper sensor installation are discussed. The second part of the contribution is about the necessity of UHF measurement comparability and reproducibility. Therefore, a new calibration procedure for the UHF method is proposed and discussed in respect of the procedure for the IEC 60270 compliant conventional electric method. The characterization of UHF sensors is a key precondition for the UHF calibration process in order to obtain calibration for the full measurement path. Sensor characteristics are described by the antenna factor (AF) which is determined under inside transformer conditions in an oil-filled Gigahertz Transversal Electromagnetic cell (GTEM cell). In addition to the calibration procedure, the performance of the installed sensor has to be determined. The evaluation is based on the concept of transmitting electromagnetic waves through the transformer tank from one UHF sensor to another. This performance check procedure is used in this contribution for the examination of the influence of the sensor's insertion depth into the tank. These results are compared to the reference GTEM cell measurement used for calibration.

8 August 2019 in Energies
Verified
Journal Article
Open access
PDF file
Martin SiegelMartin Siegel
Martin Siegel
SCSebastian Coenen
Sebastian Coenen
MBMichael Beltle
Michael Beltle
STStefan Tenbohlen
Stefan Tenbohlen
MWMarc Weber
Marc Weber
JFJitka Fuhr
Jitka Fuhr
The continuous, non-intermitted service of electrical grids relies on the reliability of their assets, e.g., power transformers. Local insulation defects can result in serve failures such as breakdowns with severe subsequent costs. The prevention of such events is crucial. Hence, partial discharge (PD) activity at power transformers is evaluated directly in the factory before shipment. Additionally, PD activity can be monitored during service using the ultra-high frequency (UHF) method. In this contribution, a calibration procedure is proposed for the UHF method. The calibration process is required to ensure both, reproducibility and comparability of UHF measurements: Only a calibrated UHF measurement procedure can be introduced supplementary to IEC 60270 in acceptance tests of power transformers. The proposed calibration method considers two factors: The influence of the UHF-antenna’s sensitivity and the PD recorder characteristics including accessories such as cable damping, pre-amplifier, etc. The former is addressed by a characterization of UHF sensors using the standard antenna factor (AF) in a gigahertz transverse electromagnetic (GTEM) cell. The PD recorder’s influence is corrected by using a defined, invariable test signal as reference for all recording devices. A practical evaluation of the proposed calibration procedure is performed in a laboratory setup using different UHF recording devices and UHF sensors using artificial PD signals and real voltage-driven PD sources.

30 January 2023 in Energies
Verified
Journal Article
Open access
PDF file
STStefan Tenbohlen
Stefan Tenbohlen
Chandra Prakash BeuraChandra Prakash Beura
Chandra Prakash Beura
Wojciech SikorskiWojciech Sikorski
Wojciech Sikorski
Ricardo AlbarracínRicardo Albarracín
Ricardo Albarracín
BCBruno Albuquerque de Castro
Bruno Albuquerque de Castro
Martin SiegelMartin Siegel
Martin Siegel
Although partial discharge (PD) measurement is a well-accepted technology to assess the quality of the insulation system of power transformers, there are still uncertainties about which frequency range PDs radiate and which frequency range should be evaluated in a measurement. This paper discusses both a UHF PD frequency range obtained from studies investigating laboratory experiments and a frequency range from numerous practical use cases with online and on-site measurements. The literature review reveals a frequency spectrum of ultrahigh-frequency (UHF) PD measurements in the range of 200 MHz to 1 GHz for most publications. Newer publications extend this range from 3 to 6 GHz. The use cases present UHF PD measurements at transformers with power ratings up to 1000 MVA to determine frequency ranges which are considered effective for practical applications. The “common” frequency range, where measurements from all use cases provide signal power, is from approximately 400 MHz to 900 MHz, but it is noted that the individual frequency range, as well as the peak UHF signal power, strongly varies from case to case. We conclude from the discussed laboratory experiments and practical observations that UHF PD measurements in power transformers using either valve or window antennas, according to Cigré, are feasible methods to detect PD.

5 August 2016 in IEEE Transactions on Dielectrics and Electrical Insulation
Verified
Journal Article
Closed access
Martin SiegelMartin Siegel
Martin Siegel
MBMichael Beltle
Michael Beltle
STStefan Tenbohlen
Stefan Tenbohlen
Common reasons for local failures in power transformers are partial discharges (PD) in the electric insulation. The ultra-high frequency (UHF) PD measurement method gained in importance for transformer diagnosis and monitoring within the last years. Due to its robustness against external noise, it is suitable for both, factory acceptance tests (FAT) and site acceptance tests (SAT). For the application at acceptance tests, it is necessary that the UHF technique is a reliable testing method and also comparable between different UHF measurement systems. Therefore, the UHF sensor's characteristic has to be included in a calibration procedure by using its antenna factor (AF). This contribution implements a custom-built oil-filled Gigahertz-Transversal-Electromagnetic cell (GTEM cell) for the AF evaluation. In the first part, the GTEM cell's design and dimensioning are illustrated and the cell is evaluated in terms of its high frequency behavior. The second part determines the AF of two different UHF sensor types: UHF Drain Valve Sensors and UHF Plate Sensors using the GTEM cell. Additionally, the influences of insertion depths and standardized gate valves on the Drain Valve Sensor's AF are taken into account.

18 March 2015 in IEEE Transactions on Electromagnetic Compatibility
Verified
Journal Article
Closed access
DSDaniel Schneider
Daniel Schneider
MBMichael Beltle
Michael Beltle
Martin SiegelMartin Siegel
Martin Siegel
STStefan Tenbohlen
Stefan Tenbohlen
WKWolfgang Kohler
Wolfgang Kohler
Electric drive systems are going to be the future of the automotive industry. Electromagnetic compatibility (EMC) issues and challenges arise with its growing entry into modern cars. This contribution provides an overview of the field dominating disturbance currents of an automotive high-voltage (HV) power inverter within an electric drive system. In order to minimize the cost and time needed for EMC measurements and engineering, a precompliance measurement method is introduced and applied to the inverter's setup. The method presented allows the calculation of radiated emissions, according to CISPR 25, needed during the development process without the need for an expensive anechoic chamber. Transfer functions in combination with measured disturbance currents on the attached HV harnesses are used to obtain a cost-efficient estimation of the radiated emissions occurring during a component test. Its theory is discussed and demonstrated using a derived model. The method is verified using a rudimentary test setup, which represents a distributed system, and is later validated by the active electric drive system test setup introduced. Examinations of repeatability and reproducibility of disturbance current measurements as well as applied EMC counter measures complete the contribution.