Partial discharge (PD) detection is a widely extended technique for electrical insulation diagnosis. Ultrahigh-frequency detection techniques appear as a feasible alternative to traditional methods owing to their inherent advantages such as the capability to detect PDs online and to locate the piece of equipment with insulation problems in substations and cables. In this paper, four antennas are thoroughly studied by means of their theoretical and experimental behavior when measuring electromagnetic pulses radiated by PD activity. The theoretic study of the band of frequencies in which the pulse emits and the measurement of the parameters $S_{11}$ are complemented with the frequency response and wavelet transform of a set of 500 time signals acquired by the antennas, and the results are analyzed in detail.
24 April 2018 in IEEE Electrical Insulation Magazine
During the last 20 years, the search for new applications for nanotechnology has become one of the busiest in science, engineering, and manufacturing. New nanotechnology-based materials with superior properties have been developed and are already used in many everyday products and processes. The application of nanotechnology to high-voltage engineering has been mainly oriented towards the development and characterization of the so-called nanodielectric materials [1]. In 1994, Lewis [2] suggested that "a major field of study in the future development of dielectrics will concern their properties when relatively few molecules are involved. Such smallness arises naturally at interfaces of nanometric thickness and will occur also when dielectrics are employed in the nano-technical devices of the future." The physical phenomena that govern the behavior of materials at sub-microscopical scale are outlined in this publication [2]. The term "nanodielectric" was introduced by Frechette [3], [4], who defined nanodielectrics as "multicomponent dielectrics possessing nanostructures, the presence of which results in the change of one or several of its dielectric properties."
In order to investigate how artificial neural networks (ANNs) have been applied for partial discharge (PD) pattern recognition, this paper reviews recent progress made on ANN development for PD classification by a literature survey. Contributions from several authors have been presented and discussed. High recognition rate has been recorded for several PD faults, but there are still many factors that hinder correct recognition of PD by the ANN, such as high-amplitude noise or wide spectral content typical from industrial environments, trial and error approaches in determining an optimum ANN, multiple PD sources acting simultaneously, lack of comprehensive and up to date databank of PD faults, and the appropriate selection of the characteristics that allow a correct recognition of the type of source which are currently being addressed by researchers. Several suggestions for improvement are proposed by the authors include: (1) determining the optimum weights in training the ANN; (2) using PD data captured over long stressing period in training the ANN; (3) ANN recognizing different PD degradation levels; (4) using the same resolution sizes of the PD patterns when training and testing the ANN with different PD dataset; (5) understanding the characteristics of multiple concurrent PD faults and effectively recognizing them; and (6) developing techniques in order to shorten the training time for the ANN as applied for PD recognition Finally, this paper critically assesses the suitability of ANNs for both online and offline PD detections outlining the advantages to the practitioners in the field. It is possible for the ANNs to determine the stage of degradation of the PD, thereby giving an indication of the seriousness of the fault.
1 September 2016 in Renewable and Sustainable Energy Reviews
The harmful effects of carbon emissions and carbon dioxide caused by over dependence on oil is a global issue, which is currently being addressed by encouraging renewable energy (RE) resources contribution to the energy mix. Encouraging RE is important in order to solve the unsustainable nature of electricity generation especially in the sub-Saharan African countries. One of the REs that have vast potential especially in sub-Saharan Africa is the solar energy. This paper provides an overview of the solar photovoltaic (PV) developments in selected countries of sub-Saharan Africa – in terms of research, installed capacity, solar radiation level, RE policies and the percentage of solar PV in the future energy mix of these countries. Finally, this paper identified the barriers to RE deployment and proposed scaling-up solar PV as one of the solution in the development of energy mix in these countries
A well-defined condition-monitoring for power transformers is key to implementing a correct condition-based maintenance (CBM). In this regard, partial discharges (PD) measurement and its analysis allows to carry out on-line maintenance following the standards IEC-60270 and IEC-60076. However, new PD measurements techniques, such as acoustics or electromagnetic (EM) acquisitions using ultra-high-frequency (UHF) sensors are being taken into account, IEC-62478. PD measurements with antennas and the effect of their EM propagation in power transformer tanks is an open research topic that is considered in this paper. In this sense, an empty tank model is studied as a rectangular cavity and their resonances are calculated and compared with their measurement with a network analyser. Besides, two low cost improved monopole antennas deployed inside and outside of the tank model capture background noise and PD pulses in three different test objects (Nomex, twisted pair and insulator). The average spectrum of them are compared and can be found that mainly, the antenna frequency response, the frequency content distribution depending on the PD source and the enclosure resonances modes are the main factors to be considered in PD acquisitions with these sensors. Finally, with this set-up, it is possible to measure PD activity inside the tank from outside.
This paper aims to promote optical partial discharge (PD) detection from laboratory scale to practical application for sulfur hexafluoride (SF6)-insulated power equipment. Firstly, a micro silicon photomultiplier (SiPM)-based PD sensor is evaluated for detecting PDs in SF6 gas and is proven to have the equivalent properties with pulse current acquisition and vacuum photomultiplier tube (PMT) in terms of the signal-to-noise ratio (SNR), pulse resolution and linearity. Then, a double-spectral PD sensor based on SiPM is first proposed and developed to realize a more specific PD diagnosis. It is demonstrated that by using the double-spectral PD sensor not only stochastic PD patterns can be obtained for PD recognition, but PD severity can be estimated as well.