Interleaved DC-DC converters have been widely used in power conversion due to their high efficiency and reliability. In the application of new energy, this plays an increasingly important role in the grid-connected power generation of wind, solar, and tidal energy. Therefore, it is crucial to ensure the reliability and proper operation of interleaved DC-DC converters. We studied an open circuit fault (OCF) diagnosis method for a three-phase interleaved buck converter. We propose a non-invasive diagnosis method based on the output voltage using the harmonic amplitude and phase at the switching frequency as the diagnostic criteria. Evaluation was carried out on a hardware-in-the-loop (HIL) test platform to prove the validity of the proposed method. The results show that the presented method had high accuracy and robustness against OCFs, which could otherwise damage the system.
With the further development of harmonic pollution in the power system, scientists have carried out research on harmonics. Among them, harmonic detection is the first step in harmonic research. In this paper, a harmonic detection method based on an observer is proposed. This method first uses the cascaded Second-Order Generalized Integration (SOGI) algorithm, which can filter the Direct Current (DC) component of the input signal to extract the fundamental frequency, and then uses a time-varying observer to extract the harmonics. This can be used to extract harmonics from a distorted online grid signal. The effectiveness of the proposed method was evaluated on the Speedgoat Rapid Control Prototype (RCP) platform. The results show that it can complete the convergence within 0.05 s, and the standard deviation after stability will not exceed 1%.
Harmonic interference is a major hazard in the current power system that affects power quality. How to extract harmonics quickly and accurately is the premise to ensure the sustainable operation of power system, which is particularly important in the field of new energy power generation. In this paper, a harmonic extraction method based on a time-varying observer is proposed. Firstly, a frequency estimation algorithm is used to estimate the power grid current frequency, which can estimate the frequency in real time. Then, applying the zero-crossing detection method to convert the frequency into a phase variable. Finally, using the phase variable and integral current signal as input, a observer is modeled to extract each order harmonic component. The proposed method is evaluated on a FGPA test platform, which shows that the method can extract the harmonic components of the grid current and converge within 80 ms even in the presence of grid distortions. In the verification case, the relative errors of the 1st, 5th, 7th and 11th harmonics are 0.005%, −0.003%, 0.251% and 0.620%, respectively, which are sufficiently small.