Po Li

Dr. Po Li


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 July 2022 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TCTengpeng Chen
Tengpeng Chen
HRHe Ren
He Ren
Po LiPo Li
Po Li
GAGehan Amaratunga
Gehan Amaratunga
Even though the noise model applied in power system dynamic state estimation (DSE) is usually assumed to be Gaussian, this is not the case due to the unknown system inputs, influence from the communication channel noise, and the outliers generated by phasor measurement units (PMUs). In this article, a robust power system DSE method combining a robust exponential-absolute-value-based estimator and the unscented Kalman filter (UKF) together is proposed under non-Gaussian noise. Based on the quadratic function and the exponential absolute value function, robust exponential-absolute-value-based estimator is derived, further mitigating the effects of bad data or outliers. The influence function is used to calculate the state estimation error covariance of the proposed robust DSE method. The simulation results on the IEEE 39-bus system verify the robustness and effectiveness of the proposed DSE method.

17 June 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Po LiPo Li
Po Li
XLXiang Li
Xiang Li
TZTao ZENG
Tao ZENG
Interleaved DC-DC converters have been widely used in power conversion due to their high efficiency and reliability. In the application of new energy, this plays an increasingly important role in the grid-connected power generation of wind, solar, and tidal energy. Therefore, it is crucial to ensure the reliability and proper operation of interleaved DC-DC converters. We studied an open circuit fault (OCF) diagnosis method for a three-phase interleaved buck converter. We propose a non-invasive diagnosis method based on the output voltage using the harmonic amplitude and phase at the switching frequency as the diagnostic criteria. Evaluation was carried out on a hardware-in-the-loop (HIL) test platform to prove the validity of the proposed method. The results show that the presented method had high accuracy and robustness against OCFs, which could otherwise damage the system.

4 April 2023 in Sensors
Verified
Journal Article
Open access
PDF file
Po LiPo Li
Po Li
XTXiao shan Tong
Xiao shan Tong
ZWZhoujing Wang
Zhoujing Wang
MXMaoguang Xu
Maoguang Xu
JZJianfeng Zhu
Jianfeng Zhu
Single-phase inverters with an output LC filter, can generate low distortion output voltages, which are suitable for uninterruptible power supply (UPS) systems. The UPS system provides emergency power in the case of utility power failure, requiring high reliability and clean power. The sensorless control method is actually a soft-sensing technique, that reduces system cost, measurement-related losses, and, especially important for UPS systems, enhances the system reliability. This paper proposes a load current sensorless finite control set model predictive control (FCS-MPC) scheme for a single-phase UPS inverter. A time varying observer is proposed, which offers the accurate estimation for individual components simultaneously in periodic load current signal, without subsequent complex calculations. Compared with another two typical sensorless methods (the low-pass filter and the Kalman filter), the proposed observer-based FCS-MPC strategy has smaller load current estimation error and lower output voltage distortion, under both linear and nonlinear loads. The theoretical analysis is verified through simulation and experiment. A single-phase inverter rapid control prototype (RCP) is set up with the Speedgoat real-time target machine, to confirm the effectiveness of the system.

1 August 2017 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
XWXiaomei Wu
Xiaomei Wu
QWQian Wang
Qian Wang
JMJinlei Ma
Jinlei Ma
WZWei Zhang
Wei Zhang
Po LiPo Li
Po Li
ZFZheng Fang
Zheng Fang
X-ray computed tomography (CT) can distinguish different materials according to their absorption characteristics. The hyperspectral X-ray CT (HXCT) system proposed in the present work reconstructs each voxel according to its X-ray absorption spectral characteristics. In contrast to a dual-energy or multi-energy CT system, HXCT employs cadmium telluride (CdTe) as the x-ray detector, which provides higher spectral resolution and separate spectral lines according to the material’s photon-counter working principle. In this paper, a specimen containing ten different polymer materials randomly arranged was adopted for material identification by HXCT. The filtered back-projection algorithm was applied for image and spectral reconstruction. The first step was to sort the individual material components of the specimen according to their cross-sectional image intensity. The second step was to classify materials with similar intensities according to their reconstructed spectral characteristics. The results demonstrated the feasibility of the proposed material identification process and indicated that the proposed HXCT system has good prospects for a wide range of biomedical and industrial nondestructive testing applications.

22 April 2019 in IEEE Access
Verified
Journal Article
Open access
Po LiPo Li
Po Li
RLRuiyu Li
Ruiyu Li
SCSiyuan Cai
Siyuan Cai
YHYongqiang Hong
Yongqiang Hong
Two-stage inverters composed of the front DC-DC stage and the rear DC-AC stage are broadly employed for the current tracking. Structures vary according to the different control objectives and the application occasions. The concerning structure in this paper is made up of the buck-boost converter stage and the single-phase inverter stage. Simulation results show that the intermediate voltage will affect the total harmonic distortion (THD) values. Moreover, under the same other conditions, a minimum THD can be attained by regulating the intermediate voltage. In this paper, a time-varying observer is introduced for the interface parameters identification based on the robustness of model predictive control (MPC) scheme. Combined with the input voltage, the reference current and grid voltage, the optimal intermediate voltage with lower THD can be determined. Besides, a cascaded proportional-integral (PI) MPC scheme is adopted for the intermediate voltage tracking without steady-state error. Meanwhile, based on accurate interface parameters obtained by the observer, an adaptive MPC scheme is applied for the output current tracking. Simulation results on MATLAB/Simulink and experimental results on FPGA test bench validate the accuracy of the voltage determination and the effectiveness of the control scheme.

21 August 2023 in Control Engineering Practice
Verified
Journal Article
Closed access
Po LiPo Li
Po Li
XTXiaoshan Tong
Xiaoshan Tong
YHYing He
Ying He
TCTengpeng Chen
Tengpeng Chen