Shuan Dong

Dr. Shuan Dong


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 December 2016 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SDShuan Dong
Shuan Dong
YCYu Christine Chen
Yu Christine Chen
This paper proposes to augment the conventional synchronverter control scheme with an auxiliary loop to freely adjust the dynamic response speed. This loop is dubbed as a damping correction loop since its form and function are reminiscent of the damping component in the classical synchronous generator model. Central to the proposed auxiliary loop is the creation of an additional tuneable parameter that allows for unrestricted adjustment of the system damping ratio without affecting the steady-state frequency droop characteristic, which is an improvement over the conventional synchronverter design. In the proposed method, relevant parameters are analytically tuned and active- and reactive-power coupling effects are reduced when operating with increased response speed. The dynamic response and robustness of the approach are verified via extensive smallsignal analysis. Furthermore, time-domain simulations highlight the advantages of the proposed method over existing ones.

9 November 2017 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SDShuan Dong
Shuan Dong
YCYu Christine Chen
Yu Christine Chen
This paper proposes a method to directly compute controller parameter values in a synchronverter augmented with a so-called damping correction loop, and in so doing, achieve desired transient and steady-state response. The proposed approach is grounded in a reduced third-order system model that captures pertinent dynamic characteristics of the synchronverter active-power loop (APL), particularly those of the dominant mode. This reduced-order model helps to identify and explain a shortcoming in a previous parameter tuning method. Central to the proposed parameter computation method is to express APL parameters of the original system as closed-form functions of the poles of the reduced-order system. Since the reduced-order model retains dominant-mode dynamic behaviours of the original system, APL parameters can be directly computed according to specified APL dominant mode. Time-domain simulations are provided to validate the accuracy of the reduced-order model and the proposed direct-computation parameter tuning method.

7 April 2015 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
SDShuan Dong
Shuan Dong
YCYongning Chi
Yongning Chi
YLYan Li
Yan Li
In this paper, we propose an idea to integrate more renewable energy into the existing China power grid and to provide remote islands with a reliable power supply. The idea is to expand the existing point-to-point line-commutated converter (LCC) HVDC transmission link into a hybrid multiterminal HVDC (hybrid MTDC) system, which contains LCC stations and voltage-source converter (VSC) stations. Accordingly, this paper proposes a novel control strategy for this system called active voltage feedback control, which does not need any high-speed communication system under various disturbances, such as wind speed variations, load fluctuations, faults, etc. This paper also adds secondary frequency regulation to the synchronverter, which is one way of combining the VSC converter with synchronous machine behavior. Then, this paper applies an approach to limit its current under fault conditions. Finally, the entire hybrid MTDC system is modeled in PSCAD/EMTDC. Simulation results show that the improved synchronverter is able to achieve secondary frequency control, and the presented active voltage feedback control works very well when exposed to various disturbances.

7 October 2019 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SDShuan Dong
Shuan Dong
Jingya JiangJingya Jiang
Jingya Jiang
YCYu Christine Chen
Yu Christine Chen
This paper proposes a self-synchronizing synchronverter controller design that leverages the addition of a virtual resistance (along with a suitable coordinate transformation) to compute feedback signals during self synchronization prior to grid connection. With respect to analysis, we exploit separation-of-time-scales arguments and develop appropriate reduced-order models, which are well-suited for studying phase-angle and voltage-magnitude self-synchronization dynamics independently. Our work provides analytical justification for the effects of pertinent controller parameters and system initial conditions on self-synchronization dynamics observed empirically in time-domain simulations. As such, it offers practical guidance on favourable parameter-value settings to achieve fast self synchronization, and it yields accurate estimates for self-synchronization times with well-tuned parameters. Through numerical simulations and experiments, we illustrate the efficacy of the proposed controller design and verify the validity of subsequent analyses.

16 October 2024 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
LDLizhi Ding
Lizhi Ding
YOYuzhu Ouyang
Yuzhu Ouyang
XLXiaonan Lu
Xiaonan Lu
JQJunjie Qin
Junjie Qin
SDShuan Dong
Shuan Dong
JTJin Tan
Jin Tan
The increasing penetration of inverter-based resources (IBRs) into the existing power systems introduces tremendous benefits for enhanced sustainability but also poses inevitable challenges in terms of insufficient inertia, potential instability, and complex network dynamics, among others. However, the additional coupling introduced by the interactions among gridfollowing (GFL) and grid-forming (GFM) IBRs and the other components (i.e., synchronous generators [SGs], loads, and network, etc.) has not been clearly explored. A holistic, scalable, and quantitative stability analysis framework with the control systems and power networks is still missing. In this paper, to fill in the technical gaps, a holistic small-signal model of the entire system with both rotating generation units and IBRs is established. An extended power flow model with operation dynamics from both generator control schemes and power networks is proposed to provide the varying steady-state operating points for small-signal modeling. The proposed method is compared with MATLAB solvers, and the results show that the proposed approach has a minimum calculation time, which can be less than 12 seconds for a large-scale power system with up to 2,000 buses. Furthermore, a quantitative method is developed to identify the impacts of IBRs on system performance with emphases on the potential stability issues with GFL IBRs, additional benefits of employing GFM IBRs, the feasibility of replacing SGs with GFM IBRs, and the impact of penetration level of different kinds of generation units. Finally, a field island power system is used to verify the proposed approach, and hardware-in-the-loop (HIL) tests are provided to further demonstrate the effectiveness of the proposed analysis.

24 March 2021 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SDShuan Dong
Shuan Dong
CCChristine Chen
Christine Chen
This paper derives in analytical closed form the feasible pole-placement region of the synchronverter active-power loop (APL) so as to eliminate all trial-and-error effort in parameter tuning. We consider the well-established setting of a reduced third-order APL model with two controller parameters that can be tuned freely. Thus, only two of the three APL poles can be specified independently in hopes of achieving desired system dynamics. Central to the presented derivation is the realization that the two specified poles must represent the dominant mode of the system. Otherwise the actual system dynamics may be dictated by the third unspecified pole, leading to unexpected or undesired dynamic behaviour. Numerical simulations involving the full-order synchronverter dynamical model and a modified IEEE 39-bus test system validate the analysis and the resulting region within which poles must be placed for actual system dynamics to match desired ones.