Jin Tan

Jin Tan

Auto-generated profile, based on publicly available information

Jin Tan

National Laboratory of the Rockies (NLR), Golden, CO (United States)

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 January 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
YLYong Liu
Yong Liu
Shutang YouShutang You
Shutang You
JTJin Tan
Jin Tan
YZYingchen Zhang
Yingchen Zhang
YLYilu Liu
Yilu Liu
Nonsynchronous generators such as photovoltaics (PVs) are expected to undermine bulk power systems (BPSs)' frequency response at high penetration levels. Though the underlying mechanism has been relatively well understood, the accurate assessment and effective enhancement of the U.S. interconnections' frequency response under extra-high PV penetration conditions remains an issue. In this paper, the industry-provided full-detail interconnection models were further validated by synchrophasor frequency measurements and realistically-projected PV geographic distribution information were used to develop extra-high PV penetration scenarios and dynamic models for the three main U.S. interconnections, including Eastern Interconnection (EI), Western Electricity Coordinating Council (WECC), and Electric Reliability Council of Texas (ERCOT). Up to 65% instantaneous PV and 15% wind penetration were simulated and the frequency response change trend of each U.S. interconnection due to the increasing PV penetration level were examined. Most importantly, the practical solutions to address the declining frequency response were discussed. This paper will provide valuable guidance for policy makers, utility operators and academic researchers not only in the U.S. but also other countries in the world.

24 July 2018 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
Mingjian CuiMingjian Cui
Mingjian Cui
JWJianhui Wang
Jianhui Wang
JTJin Tan
Jin Tan
AFAnthony R. Florita
Anthony R. Florita
YZYingchen Zhang
Yingchen Zhang
To take full advantage of the considerably high reporting rate of phasor measurement units (PMU) data, this paper develops a novel PMU-based event detection methodology. Considering the huge amount of streaming PMU data, a data compression algorithm, swinging door trending (SDT), is first used to compress the PMU data and generate multiple compression intervals. Then dynamic programming is utilized to solve the optimization problem, which is recursively constituted by a score function. Based on predefined PMU event rules, dynamic programming merges adjacent compression intervals with the same slope direction. Finally, all the PMU event features are characterized. A conventional wavelet-based event detection method is compared with the developed dynamic programming based SDT (DPSDT) method. Numerical simulations on the real-time and synthetic PMU data show that the DPSDT method can accurately detect the start-time of an event and the event placement with relatively high precision. Also, the PMU event features, including the magnitude and duration of strokes, are characterized.

11 June 2018 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
Shutang YouShutang You
Shutang You
YLYong Liu
Yong Liu
JTJin Tan
Jin Tan
MGMelanie T. Gonzalez
Melanie T. Gonzalez
XZXuemeng Zhang
Xuemeng Zhang
Yilu LiuYilu Liu
Yilu Liu
Power grid primary frequency response will be significantly impaired by photovoltaic (PV) penetration increase because of the decrease in inertia and governor response. PV inertia and governor emulation requires reserving PV output and leads to solar energy waste. This paper exploits current grid resources and explores energy storage for primary frequency response under high PV penetration at the interconnection level. Based on the actual models of the U.S. Eastern Interconnection grid and the Texas grid, effects of multiple factors associated with primary frequency response, including the governor ratio, governor deadband, droop rate, and fast load response, are assessed under high PV penetration scenarios. In addition, performance of batteries and supercapacitors using different control strategies is studied in the two interconnections. This paper quantifies the potential of various resources to improve interconnection-level primary frequency response under high PV penetration without curtailing solar output.

13 March 2020 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
ZDZerui Dong
Zerui Dong
JTJin Tan
Jin Tan
EMEduard Muljadi
Eduard Muljadi
RNR. M. Nelms
R. M. Nelms
ASAntoine St-Hilaire
Antoine St-Hilaire
MJMark D. Jacobson
Mark D. Jacobson
Quaternary pumped storage hydropower (Q-PSH) technology, as one of the new advanced-PSH technology, has been developed by taking advantage of Conventional-PSH (C-PSH) and Adjustable Speed-PSH (AS-PSH). By combining adjustable-speed pump unit and conventional hydropower turbine unit in the quaternary configuration, Q-PSH has the more competitive capability of providing fast power support in the future high renewable penetrated power system. Acting as energy storage (ES), Q-PSH provides promising power supply to deal with the uncertainty and variability from renewable energy generation. This paper focuses on the dynamic modeling of Q-PSH technology employing full-converter machine and the impact of Q-PSH on the frequency response in a system. The detailed model of Q-PSH is developed and implemented in the IEEE 14-bus system based on GE Positive Sequence Load Flow (PSLF) platform, which captures the dynamic of multiple operation modes, especially hydraulic short-circuit (HSC) operation mode. Several cases are set up to reveal the advantages of Q-PSH technology when power electronic based renewable energy generation is deployed in the system. Sensitivity studies of the controller in pump governor show the impact of parameters in pump response performance. The comparison case illustrates the impact of frequency response provided by the Q-PSH in the system.

3 January 2020 in IEEE Transactions on Power Systems
Verified
Journal Article
Closed access
HGHuajie Gu
Huajie Gu
RYRuifeng Yan
Ruifeng Yan
TSTapan Saha
Tapan Saha
EMEduard Muljadi
Eduard Muljadi
JTJin Tan
Jin Tan
YZYingchen Zhang
Yingchen Zhang

13 December 2023 in IEEE Transactions on Power Delivery
Verified
Journal Article
Open access
MXMin Xiong
Min Xiong
BWBin Wang
Bin Wang
DVDeepthi Vaidhynathan
Deepthi Vaidhynathan
JMJonathan Maack
Jonathan Maack
MRMatthew J. Reynolds
Matthew J. Reynolds
JTJin Tan
Jin Tan
The electromagnetic transient (EMT) simulation is an essential tool for studying power grids dominated by inverter-based resources (IBRs). However, due to small simulation time steps and increasing problem sizes , performing EMT simulations for large-scale power grids becomes computational-intensive, and often impractical. To address this challenge, we developed ParaEMT, an open-source Python-based EMT simulator that is parallelizable and compatible with high-performance computing (HPC) systems for simulating large-scale power grids with a significant presence of IBRs. Its key features include: 1) utilizing parallel computation for network solution by decomposing the network conductance matrix into the bordered block diagonal form; 2) enabling parallel updates of device states and network historical currents; 3) leveraging HPC to further accelerate simulation through a developed generic interface. The accuracy of ParaEMT has been validated on the reduced 240-bus (720-node) Western Electricity Coordinating Council system by benchmarking the EMT dynamics against PSCAD. Furthermore, ParaEMT achieves a notable speedup of approximately 25 to 36 times on a synthetic 10,080-bus (30240-node) system by leveraging the HPC resource named Eagle at the National Renewable Energy Laboratory. A regional 100% renewable case of the reduced 240-bus system has been developed for simulating system-wide IBRs’ interactions in large-scale power grids using ParaEMT.