Advances in micro- and nanotechnology have led to rapid employment of spintronic sensors in both recording and non-recording applications. These state-of-the-art magnetoresistive spintronic sensors exhibit high sensitivities and ultra-low field detectivities that meet requirements of smart sensing applications in the fields of internet of things, mobile devices, space technology, aeronautics, magnetic flux leakage, domotics, the environment, and healthcare. Moreover, their ability to be customized and miniaturized, ease of integration, and cost-effective nature make these sensors uniquely competitive with regard to mass production. In this study, we discuss magnetoresistive field sensors based on the planar-Hall effect, which are very promising for their high sensitivity and sensing ultra-low magnetic fields. We provide a detailed historical overview and discuss recent dramatic developments in several application fields. In addition, we discuss sensor material property requirements, design architectures, noise-reduction techniques, and sensing capabilities, along with the high repeatabilities and good flexibility characteristics of such devices. All of these high-performance characteristics apply across a wide temperature range and make the sensor robust when used in various novel applications. The sensor also appears promising because it is cost-effective and can be used in micro-sensing applications. Recently, a noteworthy study that combined integrated planar-Hall magnetoresistive sensors with microfluidic channels revealed their potential for highly localized magnetic field sensing. This characteristic makes them suitable for point-of-care-technologies that require resolutions of a few pT at room temperature.
Magnetic sensors have great potential for biomedical applications, particularly, detection of magnetically-labeled biomolecules and cells. On the basis of the advantage of the planar Hall effect sensor, which consists of improved thermal stability as compared with other magnetic sensors, we have designed a portable biosensor platform that can detect magnetic labels without applying any external magnetic field. The trilayer sensor, with a composition of Ta (5 nm)/NiFe (10 nm)/Cu (x = 0 nm~1.2 nm)/IrMn (10 nm)/Ta (5 nm), was deposited on a silicon wafer using photolithography and a sputtering system, where the optimized sensor sensitivity was 6 μV/(Oe∙mA). The detection of the magnetic label was done by comparing the signals obtained in first harmonic AC mode (1f mode) using an external magnetic field and in the second harmonic AC mode (2f mode) with a self-field generated by current passing through the sensor. In addition, a technique for the β-amyloid biomarker-based antibody-antigen sandwich model was demonstrated for the detection of a series of concentrations of magnetic labels using the self-field mode method, where the signal-to-noise ratio (SNR) was high. The generated self-field was enough to detect an immobilized magnetic tag without an additional external magnetic field. Hence, it could be possible to reduce the device size to use the point-of-care testing using a portable circuit system.
Advanced microelectromechanical system (MEMS) magnetic field sensor applications demand ultra-high detectivity down to the low magnetic fields. To enhance the detection limit of the magnetic sensor, a resistance compensator integrated self-balanced bridge type sensor was devised for low-frequency noise reduction in the frequency range of 0.5 Hz to 200 Hz. The self-balanced bridge sensor was a NiFe (10 nm)/IrMn (10 nm) bilayer structure in the framework of planar Hall magnetoresistance (PHMR) technology. The proposed resistance compensator integrated with a self-bridge sensor architecture presented a compact and cheaper alternative to marketable MEMS MR sensors, adjusting the offset voltage compensation at the wafer level, and led to substantial improvement in the sensor noise level. Moreover, the sensor noise components of electronic and magnetic origin were identified by measuring the sensor noise spectral density as a function of temperature and operating power. The lowest achievable noise in this device architecture was estimated at ~3.34 at 100 Hz.
The resolution of planar-Hall magnetoresistive (PHMR) sensors was investigated in the frequency range from 0.5 Hz to 200 Hz in terms of its sensitivity, average noise level, and detectivity. Analysis of the sensor sensitivity and voltage noise response was performed by varying operational parameters such as sensor geometrical architectures, sensor configurations, sensing currents, and temperature. All the measurements of PHMR sensors were carried out under both constant current (CC) and constant voltage (CV) modes. In the present study, Barkhausen noise was revealed in 1/f noise component and found less significant in the PHMR sensor configuration. Under measured noise spectral density at optimized conditions, the best magnetic field detectivity was achieved better than 550 pT/√Hz at 100 Hz and close to 1.1 nT/√Hz at 10 Hz for a tri-layer multi-ring PHMR sensor in an unshielded environment. Furthermore, the promising feasibility and possible routes for further improvement of the sensor resolution are discussed.
Planar Hall magnetoresistance (PHMR) sensors are widely utilized due to their high sensitivity, simple structure, and cost-effectiveness. However, their performance is influenced by both the driving mode and the thickness of the ferromagnetic layer, yet the combined effects of these factors remain insufficiently explored. This study systematically investigates the impact of Ni80Fe20 thickness (5–35 nm) on PHMR sensor performance under constant current (CC) and constant voltage (CV) modes, with a focus on optimizing the peak-to-peak voltage (Vp-p). In CC mode, electron surface scattering at 5–10 nm increases resistance, leading to a sharp rise in Vp-p, followed by a decline as the thickness increases. In contrast, CV mode minimizes resistance-related effects, with sensor signals predominantly governed by magnetization-dependent resistivity. Experimentally, the optimal Vp-p was observed at 25 nm in CV mode. However, for thicknesses beyond this point, the reduction in sensor resistance suggests that voltage distribution across both the sensor and external load resistance significantly influences performance. These findings provide practical insights into optimizing PHMR sensors by elucidating the interplay between driving modes and material properties. The results contribute to the advancement of high-performance PHMR sensors with enhanced signal stability and sensitivity for industrial and scientific applications.