Diganta Dutta

Dr. Diganta Dutta


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Lanju MeiLanju Mei
Lanju Mei
DCDefu Cui
Defu Cui
JSJiayue Shen
Jiayue Shen
DDDiganta Dutta
Diganta Dutta
WBWillie Brown
Willie Brown
IDIbibia Dabipi
Ibibia Dabipi
This paper investigates the electroosmotic micromixing of non-Newtonian fluid in a microchannel with wall-mounted obstacles and surface potential heterogeneity on the obstacle surface. In the numerical simulation, the full model consisting of the Navier–Stokes equations and the Poisson–Nernst–Plank equations are solved for the electroosmotic fluid field, ion transport, and electric field, and the power law model is used to characterize the rheological behavior of the aqueous solution. The mixing performance is investigated under different parameters, such as electric double layer thickness, flow behavior index, obstacle surface zeta potential, obstacle dimension. Due to the zeta potential heterogeneity at the obstacle surface, vortical flow is formed near the obstacle surface, which can significantly improve the mixing efficiency. The results show that, the mixing efficiency can be improved by increasing the obstacle surface zeta potential, the flow behavior index, the obstacle height, the EDL thickness.

1 September 2017 in Micron
Verified
Journal Article
Closed access
DDDiganta Dutta
Diganta Dutta
XPXavier-Lewis Palmer
Xavier-Lewis Palmer
AAAnthony Asmar
Anthony Asmar
MSMichael Stacey
Michael Stacey
SQShizhi Qian
Shizhi Qian

1 February 2018 in Micron
Verified
Journal Article
Closed access
DDDiganta Dutta
Diganta Dutta
XPXavier-Lewis Palmer
Xavier-Lewis Palmer
JKJinhyun Kim
Jinhyun Kim
SQShizhi Qian
Shizhi Qian
MSMichael Stacey
Michael Stacey

25 May 2024 in Fluids
Verified
Journal Article
Open access
PDF file
DDDiganta Dutta
Diganta Dutta
XPXavier-Lewis Palmer
Xavier-Lewis Palmer
JLJung Yul Lim
Jung Yul Lim
Surabhi ChandraSurabhi Chandra
Surabhi Chandra
Microfluidic devices have long been useful for both the modeling and diagnostics of numerous diseases. In the past 20 years, they have been increasingly adopted for helping to study those in the family of breast cancer through characterizing breast cancer cells and advancing treatment research in portable and replicable formats. This paper adds to the body of work concerning cancer-focused microfluidics by proposing a simulation of a hypothetical bi-ended three-pronged device with a single channel and 16 electrodes with 8 pairs under different voltage and frequency regimes using COMSOL. Further, a study was conducted to examine the frequencies most effective for ACEO to separate cancer cells and accompanying particles. The study revealed that the frequency of EF has a more significant impact on the separation of particles than the inlet velocity. Inlet velocity variations while holding the frequency of EF constant resulted in a consistent trend showing a direct proportionality between inlet velocity and net velocity. These findings suggest that optimizing the frequency of EF could lead to more effective particle separation and targeted therapeutic interventions for breast cancer. This study hopefully will help to create targeted therapeutic interventions by bridging the disparity between in vitro and in vivo models.

20 April 2023 in Surfaces
Verified
Journal Article
Open access
PDF file
DDDiganta Dutta
Diganta Dutta
KSKeifer Smith
Keifer Smith
XPXavier-Lewis Palmer
Xavier-Lewis Palmer
Microfluidic devices are increasingly utilized in numerous industries, including that of medicine, for their abilities to pump and mix fluid at a microscale. Within these devices, microchannels paired with microelectrodes enable the mixing and transportation of ionized fluid. The ionization process charges the microchannel and manipulates the fluid with an electric field. Although complex in operation at the microscale, microchannels within microfluidic devices are easy to produce and economical. This paper uses simulations to convey helpful insights into the analysis of electrokinetic microfluidic device phenomena. The simulations in this paper use the Navier–Stokes and Poisson Nernst–Planck equations solved using COMSOL to determine the maximum attainable fluid velocity with an electric potential applied to the microchannel and the most suitable frequency or voltage to use for transporting the fluid. Alternating current electroosmosis (ACEO) directs and provides velocity to the ionized fluid. ACEO can also mix the fluid at low frequencies for the purpose of dispersing particles. DC electroosmosis (DCEO) applies voltage along the microchannel to create an electric field that ionizes fluid within the microchannel, making it a cost-effective method for transporting fluid. This paper explores a method for an alternate efficient utilization of microfluidic devices for efficient mixing and transportation of ionized fluid and analyzes the electrokinetic phenomena through simulations using the Navier–Stokes and Poisson Nernst–Planck equations. The results provide insights into the parameters at play for transporting the fluid using alternating current electroosmosis (ACEO) and DC electroosmosis (DCEO).

15 September 2024 in Cancers
Verified
Journal Article
Open access
PDF file
DDDiganta Dutta
Diganta Dutta
MZMatthew Ziemke
Matthew Ziemke
PSPayton G Sindelar
Payton G Sindelar
HVHernan Alonzo Vargas
Hernan Alonzo Vargas
JLJung Yul Lim
Jung Yul Lim
Surabhi ChandraSurabhi Chandra
Surabhi Chandra
Diabetes greatly reduces the survival rates in breast cancer patients due to chemoresistance and metastasis. Reorganization of the cytoskeleton is crucial to cell migration and metastasis. Regulatory cytoskeletal protein kinases such as the Rho kinase (ROCK) and focal adhesion kinase (FAK) play a key role in cell mobility and have been shown to be affected in cancer. It is hypothesized that diabetes/high-glucose conditions alter the cytoskeletal structure and, thus, the elasticity of breast cancer cells through the ROCK and FAK pathway, which can cause rapid metastasis of cancer. The aim of the study was to investigate the role of potential mediators that affect the morphology of cancer cells in diabetes, thus leading to aggressive cancer. Breast cancer cells (MDA-MB-231 and MCF-7) were treated with 5 mM glucose (low glucose) or 25 mM glucose (high glucose) in the presence of Rho kinase inhibitor (Y-27632, 10 mM) or FAK inhibitor (10 mM). Cell morphology and elasticity were monitored using atomic force microscopy (AFM), and actin staining was performed by fluorescence microscopy. For comparative study, normal mammary breast epithelial cells (MCF-10A) were used. It was observed that high-glucose treatments modified the cytoskeleton of the cells, as observed through AFM and fluorescence microscopy, and significantly reduced the elasticity of the cells. Blocking the ROCK or FAK pathway diminished the high-glucose effects. These changes were more evident in the breast cancer cells as compared to the normal cells. This study improves the knowledge on the cytoarchitecture properties of diabetic breast cancer cells and provides potential pathways that can be targeted to prevent such effects.