Lanju Mei

Dr. Lanju Mei

Department of Engineering and Aviation Sciences, University of Maryland Eastern Shore, Princess Anne, MD 21853, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2021 in Micromachines
Verified
Journal Article
Open access
PDF file
Lanju MeiLanju Mei
Lanju Mei
DCDefu Cui
Defu Cui
JSJiayue Shen
Jiayue Shen
DDDiganta Dutta
Diganta Dutta
WBWillie Brown
Willie Brown
IDIbibia Dabipi
Ibibia Dabipi
This paper investigates the electroosmotic micromixing of non-Newtonian fluid in a microchannel with wall-mounted obstacles and surface potential heterogeneity on the obstacle surface. In the numerical simulation, the full model consisting of the Navier–Stokes equations and the Poisson–Nernst–Plank equations are solved for the electroosmotic fluid field, ion transport, and electric field, and the power law model is used to characterize the rheological behavior of the aqueous solution. The mixing performance is investigated under different parameters, such as electric double layer thickness, flow behavior index, obstacle surface zeta potential, obstacle dimension. Due to the zeta potential heterogeneity at the obstacle surface, vortical flow is formed near the obstacle surface, which can significantly improve the mixing efficiency. The results show that, the mixing efficiency can be improved by increasing the obstacle surface zeta potential, the flow behavior index, the obstacle height, the EDL thickness.

31 October 2019 in Micromachines
Verified
Journal Article
Open access
PDF file
Lanju MeiLanju Mei
Lanju Mei
SQShizhi Qian
Shizhi Qian
Electroosmotic flow (EOF) of viscoelastic fluid with Linear Phan-Thien–Tanner (LPTT) constitutive model in a nanochannel connecting two reservoirs is numerically studied. For the first time, the influence of viscoelasticity on the EOF and the ionic conductance in the micro-nanofluidic interconnect system, with consideration of the electrical double layers (EDLs), is investigated. Regardless of the bulk salt concentration, significant enhancement of the flow rate is observed for viscoelastic fluid compared to the Newtonian fluid, due to the shear thinning effect. An increase in the ionic conductance of the nanochannel occurs for the viscoelastic fluid. The enhancement of the ionic conductance is significant under the overlapping EDLs condition.

8 June 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
Lanju MeiLanju Mei
Lanju Mei
SQShizhi Qian
Shizhi Qian
Microfluidics has seen a remarkable growth over the past few decades, with its extensive applications in engineering, medicine, biology, chemistry, etc

18 July 2025 in Surfaces
Verified
Journal Article
Open access
PDF file
DDDiganta Dutta
Diganta Dutta
XPXavier-Lewis Palmer
Xavier-Lewis Palmer
DCDebajit Chakraborty
Debajit Chakraborty
Lanju MeiLanju Mei
Lanju Mei
We present a buffer-pH-modulated electrokinetic concentration strategy in MEMS microchannels that harnesses simple pH shifts to neutralize and charge proteins, reversibly “pausing” them at a planar electric-gate electrode by tuning to their isoelectric point (pI) and mobilizing them with slight pH offsets under an applied field. This synergistic coupling of dynamic pH control and electrode-gated focusing, which requires only buffer composition changes, enables rapid and tunable protein capture and release across diverse channel geometries for lab-on-chip, preparative, and point-of-care diagnostics. Moreover, it dovetails with established MEMS biomedical platforms ranging from diagnostics to drug delivery and microsurgery to gene and cell-manipulation devices. Future work on tailored electrode coatings and optimized channel profiles will further boost selectivity, speed, and integration in sub-100 µm MEMS devices.

30 June 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
DDDiganta Dutta
Diganta Dutta
Lanju MeiLanju Mei
Lanju Mei
XPXavier-Lewis Palmer
Xavier-Lewis Palmer
MZMatthew Ziemke
Matthew Ziemke
In this study, we present a comprehensive numerical investigation of alternating-current electrothermal (ACET) pumping strategies tailored for energy-efficient microfluidic applications. Using coupled electrokinetic and thermal multiphysics simulations in narrow microchannels, we systematically explore the effects of channel geometry, electrode asymmetry and external heating on flow performance and thermal management. A rigorous mesh convergence study confirms velocity deviations below ±0.006 µm/s across the entire operating envelope, ensuring reliable prediction of ACET-driven flows. We demonstrate that increasing channel height from 100 µm to 500 µm reduces peak temperatures by up to 79 K at a constant 2 W heat input, highlighting the critical role of channel dimensions in convective heat dissipation. Introducing a localized external heat source beneath asymmetric electrode pairs enhances convective circulations, while doubling the fluid’s electrical conductivity yields a ~29% increase in net flow rate. From these results, we derive practical design guidelines—combining asymmetric electrode layouts, tailored channel heights, and external heat bias—to realize self-regulating, low-power microfluidic pumps. Such devices hold significant promises for on-chip semiconductor cooling, lab-on-a-chip assays and real-time thermal control in high-performance microelectronic and analytical systems.

1 November 2022 in Engineering Proceedings
Verified
Conference Paper
Open access
PDF file
JSJiayue Shen
Jiayue Shen
Lanju MeiLanju Mei
Lanju Mei
DJDaniel K. Jones
Daniel K. Jones
WCWeiru Chen
Weiru Chen
XWXianping Wang
Xianping Wang
MGMinghao Geng
Minghao Geng
This paper conducts a numerical study to prove the concept of a low-cost microfluidic-based strain sensor and investigates the key design parameters that affect the sensor sensitivity by using both theoretical and finite element models. The strain sensor is composed of an electrolyte-enabled microchannel integrated with a pair of interconnects and silicone-based packaging. The results show that the strain sensor has the highest sensitivity at the following chosen design parameters: the width and length of the primary microchannel are set at 0.2 mm and 20 mm, width ratio equals 2, and number of grid lines is 10.