Alfonso Savastano

Prof. Alfonso Savastano

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 July 2018 in Graefe's Archive for Clinical and Experimental Ophthalmology
Verified
Journal Article
Closed access
PDF file
RMRita Mencucci
Rita Mencucci
EFEleonora Favuzza
Eleonora Favuzza
OCOrsola Caporossi
Orsola Caporossi
ASAlfonso Savastano
Alfonso Savastano
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo

1 May 2020 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
FBFrancesco Barca
Francesco Barca
TCTomaso Caporossi
Tomaso Caporossi
LALorenzo De Angelis
Lorenzo De Angelis
FGFabrizio Giansanti
Fabrizio Giansanti
ASAlfonso Savastano
Alfonso Savastano
SRStanislao Rizzo
Stanislao Rizzo
Purpose: To assess the surgical and refractive outcomes of a new technique of sutureless scleral fixation (SSF) using a single-piece foldable acrylic intraocular lens (IOL) (Carlevale). Setting: Department of Translational Surgery and Medicine, Ophthalmology, University of Florence, Careggi, Florence, Italy. Design: Prospective observational case series. Methods: Thirty-two eyes of 32 patients with aphakia, dislocated IOL, or subluxated lens who underwent SSF with a novel single-piece hydrophilic acrylic IOL were studied. Preoperative and postoperative refractive status and complications during and after surgery were recorded. The IOL tilt was evaluated using anterior segment optical coherence tomography (AS-OCT). Results: Twenty-two eyes were IOL/bag luxations, 9 were aphakia, and 3 were subluxated crystalline lens. Mean preoperative corrected distance visual acuity was 0.46 ± 0.29 logarithm of the minimum angle of resolution (logMAR) and improved to 0.13 ± 0.12 logMAR (P < .05) at the 8-month follow-up, with a predictive error spherical equivalent of −0.24 ± 0.81 diopters (D); the IOL tilt was 2.08 ± 1.19 degrees. One patient (3.1%) experienced transient cystoid macular edema, and 1 (3.1%) experienced vitreous hemorrhage; pigment dispersion with AS-OCT findings of reverse pupillary block was found in 2 (6.2%) eyes. IOL dislocation, conjunctival erosion, and plug externalization were not observed in any eye during the follow-up. Conclusions: SSF using the novel IOL could be a viable option for the management of aphakia, lens subluxation, and IOL–bag complex dislocation with unique characteristics of stability. The advantages of this technique were the absence of haptic manipulation, self-centration, and firm fixation of the IOL.

8 September 2020 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
ASAlfonso Savastano
Alfonso Savastano
ECEmanuele crincoli
Emanuele crincoli
MSMaria Cristina Savastano
Maria Cristina Savastano
SYSaad Younis
Saad Younis
GGGloria Gambini
Gloria Gambini
GGGemelli Against COVID-19 Post-Acute Care Study Group
Gemelli Against COVID-19 Post-Acute Care Study Group
The ability of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2′s) to cause multi-organ ischemia and coronavirus-induced posterior segment eye diseases in mammals gave concern about potential sight-threatening ischemia in post coronavirus disease 2019 patients. The radial peripapillary capillary plexus (RPCP) is a sensitive target due to the important role in the vascular supply of the peripapillary retinal nerve fiber layer (RNFL). Eighty patients one month after SARS-CoV-2 infection and 30 healthy patients were selected to undergo structural OCT (optical coherence tomography) and OCTA (optical coherence tomography angiography) exams. Primary outcome was a difference in RPCP perfusion density (RPCP-PD) and RPCP flow index (RPCP-FI). No significant difference was observed in age, sex, intraocular pressure (IOP) and prevalence of myopia. RPCP-PD was lower in post SARS-CoV-2 patients compared to controls. Within the post-COVID-19 group, patients with systemic arterial hypertension had lower RPCP-FI and age was inversely correlated to both RPCP-FI and RPCP-PD. Patients treated with lopinavir + ritonavir or antiplatelet therapy during admission had lower RPCP-FI and RPCP-PD. RNFL average thickness was linearly correlated to RPCP-FI and RPCP-PD within post-COVID-19 group. Future studies will be needed to address the hypothesis of a microvascular retinal impairment in individuals who recovered from SARS-CoV-2 infection.

9 February 2022 in Vision
Verified
Journal Article
Open access
PDF file
GGGloria Gambini
Gloria Gambini
MCMatteo Mario Carlà
Matteo Mario Carlà
FGFederico Giannuzzi
Federico Giannuzzi
TCTomaso Caporossi
Tomaso Caporossi
UVUmberto De Vico
Umberto De Vico
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
For moderate-to-severe glaucoma, trabeculectomy remains the “gold standard” intraocular pressure (IOP)-lowering treatment; nonetheless, this method requires extensive post-operative maintenance. Microinvasive glaucoma surgery (MIGS) treatments are designed to lessen intra- and post-operative care burden while offering an acceptable IOP decrease for individuals with mild to moderate glaucoma. The PreserFlo® MicroShunt (previously InnFocus MicroShunt) is an 8.5 mm glaucoma drainage device manufactured from poly(styrene-block-isobutylene-block-styrene) (SIBS), an extremely biocompatible and bioinert material. The lumen is narrow enough to prevent hypotony, but big enough to avoid being obstructed by sloughed cells or pigment. The device is implanted ab externo, as a stand-alone procedure or in conjunction with cataract surgery, with intraoperative mitomycin C, and a bleb is produced under the conjunctiva and Tenon’s capsule. The MicroShunt was CE-marked in 2012 and designed for primary open-angle glaucoma, the IOP of which remains uncontrolled after maximally tolerated topical treatment. Several clinical trials evaluating the MicroShunt’s long-term safety and effectiveness have been conducted, highlighting the effectiveness of the device over time, along with a tolerable safety profile. The present review aims to gather evidence of PreserFlo’s effectiveness and safety results almost 10 years after its introduction, and furthermore, to compare it with other MIGS and with the gold-standard trabeculectomy for glaucoma management.

1 April 2018 in Retina
Verified
Journal Article
Closed access
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
GAGiacomo Abbruzzese
Giacomo Abbruzzese
ASAlfonso Savastano
Alfonso Savastano
FGFabrizio Giansanti
Fabrizio Giansanti
TCTomaso Caporossi
Tomaso Caporossi
GVGianni Virgili
Gianni Virgili

31 May 2018 in Acta Ophthalmologica
Verified
Journal Article
Open access
Stanislao RizzoStanislao Rizzo
Stanislao Rizzo
ASAlfonso Savastano
Alfonso Savastano
LFLucia Finocchio
Lucia Finocchio
MSMaria Cristina Savastano
Maria Cristina Savastano
NKNeha Khandelwal
Neha Khandelwal
RARupesh Agrawal
Rupesh Agrawal
Purpose: To study the structural changes in the choroid using swept‐source (SS) optical coherence tomography (OCT), a tool for the choroidal vascularity index (CVI) following epiretinal membrane removal.Methods: Fifty‐two eyes of 26 patients were evaluated in this prospective, single‐centre, observational study. Twenty‐six eyes underwent vitrectomy for epiretinal membrane removal (VT‐group), and the control group consisted of 26 corresponding fellow eyes (F‐group). All patients were evaluated at baseline, 30 and 90 days postsurgery. Using a modified image binarization algorithm for SS‐OCT scans, the subfoveal choroidal area was segmented into the luminal and stromal areas, and the CVI was measured by calculating the proportion of the luminal area (LA) to the cross‐sectional choroid area.Results: The mean CVI in the VT‐group was 63.86 ± 4.04% at the baseline, 62.45 ± 4.21% at 30 days postsurgery and 61.06 ± 3.79% at 90 days (p < 0.001). The F‐group had a mean CVI of 61.12 ± 2.29% at the baseline, 60.91 ± 2.25% at 30 days postsurgery and 61.05 ± 2.28% at 90 days (p = 0.29).Conclusion: The CVI decreases following epiretinal membrane removal when compared to the fellow eyes, which suggests structural changes in the vascular layers of the choroid. The implication of these results may be that secondary inflammation resulting from mechanical traction induces choroidal thickness by way of increased vascularization of the choroid.