Radiative hyperthermia is a clinically applied cancer treatment modality where antenna design is crucial to achieving therapeutic goals. Serving as the building block of a phased‐array configuration, antennas are typically arranged in a cylindrical or elliptical array called applicator. This short communication proposes an elliptical phased array applicator based on a compact, UWB design from the category of double‐ridged horn antennas customized for hyperthermia systems. The performance of the antenna, named open ridged‐waveguide, has been experimentally assessed based on the quality metrics of the hyperthermic community. The proposed design achieves an ultra‐wideband range of operation from 400 to 800 MHz with an aperture size of 3 by 4 cm. Moreover, thanks to the shielding provided by the metallic housing, the design proves good isolation better than −30 dB throughout the band. The power deposition capability of the proposed applicator followed by the thermal analysis is also investigated for a realistic head and neck patient model. The results indicate very good quality metrics achieved in the treatment planning of the patient.
12 October 2015 in Inverse Problems in Science and Engineering
This research investigated imaging quality of two important methods widely used in electromagnetic inverse scattering problems. The algorithms, time reversal (TR) and linear sampling method (LSM), were compared for resolution of point imaging and a correlation indicator to determine image quality. Comparisons were made in single- and multifrequency modes for 2D scenarios in free-space. Comparisons revealed that resolution of TR is much better than LSM. In order to compare the total reconstructed images, several cases were considered to determine a comprehensive conclusion. The simulations were done based on experimental data. In this case, comparisons showed that in the term of correlation indicator, LSM surpasses TR.
13 January 2022 in IET Microwaves, Antennas & Propagation
Antennas are the building block of radiative hyperthermia (HT) applicators. This study proposes a compact UWB antenna specifically tailored to meet the requirements for deep HT array applicators. The proposed Open Ridged‐Waveguide (ORWG) antenna, which is an adaptation of a double‐ridged horn antenna, operates over the frequency band of 400–800 MHz. It was experimentally assessed as a single element. The quality metrics considered were reflection coefficient, penetration depth, effective field size (EFS), and mutual coupling. The design shows a 75.5% fractional bandwidth with a reflection coefficient measured to be below −10 dB from 367 up to 820 MHz. The EFS is greater than the physical dimensions of the 3‐by‐4 cm aperture. The mutual coupling between two adjacent elements in the array, measured in a flat phantom arrangement, is lower than −30 dB throughout the entire band. The antenna's performance was further tested in two deep HT scenarios in order to assess the mutual coupling and focussing abilities while in the array configuration. To this end, phased array applicators consisting of 10 and 16 ORWG antennas were simulated in CST, and the results are presented for a homogeneous cylindrical muscle phantom and a realistic patient model, respectively. The good agreement between the simulated and measured results suggests that the antenna can be successfully used for HT.
1 October 2020 in Journal of Inverse and Ill-posed Problems
Integration of an adaptive finite element method (AFEM) with a conventional least squares method has been presented. As a 3D full-wave forward solver, CST Microwave Studio has been used to model and extract both electric field distribution in the region of interest (ROI) and S-parameters of a circular array consisting of 16 monopole antennas. The data has then been fed into a differential inversion scheme to get a qualitative indicator of how the temperature distribution evolves over a course of the cooling process of a heated object. Different regularization techniques within the Tikhonov framework are also discussed, and a balancing principle for optimal choice of the regularization parameter was used to improve the image reconstruction quality of every 2D slice of the final image. Targets are successfully imaged via proposed numerical methods.