Various flexible tactile sensors based on micro/nano-fabrication technology have been developed to amplify a measured pulse signal for accuracy. Yet, these sensors suffer from complicated configurations and fabrication complexity. This work is aimed to investigate the feasibility of amplifying a measured pulse signal by adding a uniform polydimethylsiloxane (PDMS) layer to a Pyrex-based microfluidic tactile sensor. The amplifying mechanism of the proposed approach is revealed by theories on sensor-artery interaction. The pulse signals at the radial artery (RA) deep under the skin and the superficial temporal artery (STA) near the skin of one subject are measured by the sensor first with no uniform layer and then with a set of uniform layers with different mixing ratios of PDMS and thickness. Arterial parameters: elasticity, viscosity and radius, are estimated from the measured pulse signals. As compared to those measured with no uniform layer, a uniform layer generates a pulse signal at transmural pressure ( $\text{P}_{\text {T}}$ ) near zero, greatly amplifies the measured pulse signal at both arteries, causes a moderate increase in estimated arterial elasticity, and has negligible effect on estimated arterial viscosity and radius. Due to their anatomical difference, pulse signal amplification is attributed to improved pulse transmission at tissue-sensor interface at the RA and alleviated suppression of the true pulse signal at the STA. The effect of overlying tissue and a uniform layer on estimated arterial parameters is further discussed. The proposed solution offers a low-cost solution to acquiring an amplified pulse signal at $\text{P}_{\text {T}}$ near zero for CV health assessment.
The aim of this paper is to analyze the radial and longitudinal motion of the arterial wall in the context of pulsatile pressure and flow, and to understand their physiological implications for the cardiovascular system. A reexamination of the well-established one-dimensional governing equations for axial blood flow in the artery and the constitutive equation for the radial dilation of the arterial wall shows that two waves—a pulsatile pressure wave in the artery and a radial displacement wave in the arterial wall—propagate simultaneously along the arterial tree with the same propagation velocity, explaining why this velocity combines the physical properties and geometries of both the blood and the arterial wall. With consideration of their coupling, the governing equations for the radial motion and longitudinal motion of the arterial wall are derived separately. The driving force for the radial motion of the arterial wall arises from its longitudinal motion. The longitudinal motion of the arterial wall is the standard longitudinal elastic wave with two driving forces: one associated with the pulsatile flow rate and the other associated with the radial motion. These derived governing equations shed insights on some recent experimental findings in the literature, including the correlation of measured arterial wall stiffness (solely based on the radial motion) to its longitudinal motion, the decreasing trend of arterial wall distensibility from the aorta to the periphery, the underlying mechanism of the longitudinal motion pattern of the common carotid arterial wall, and the motion pattern variation in longitudinal motion with aging and diseases.
Motion artifacts (MA) are a key factor affecting the accuracy of a measured arterial pulse signal at rest. This paper presents a generalized time–frequency method for MA removal that is built upon a single-degree-of-freedom (SDOF) model of MA, where MA is manifested as time-varying system parameters (TVSPs) of the SDOF system for the tissue–contact-sensor (TCS) stack between an artery and a sensor. This model distinguishes the effects of MA and respiration on the instant parameters of harmonics in a measured pulse signal. Accordingly, a generalized SDOF-model-based time–frequency (SDOF-TF) method is developed to obtain the instant parameters of each harmonic in a measured pulse signal. These instant parameters are utilized to reconstruct the pulse signal with MA removal and extract heart rate (HR) and respiration parameters. The method is applied to analyze seven measured pulse signals at rest under different physiological conditions using a tactile sensor and a PPG sensor. Some observed differences between these conditions are validated with the related findings in the literature. As compared to instant frequency, the instant initial phase of a harmonic extracts respiration parameters with better accuracy. Since HR variability (HRV) affects arterial pulse waveform (APW), the extracted APW with a constant HR serves better for deriving arterial indices.
This study presents a two degree-of-freedom (2-DOF) model of the artery-sensor system that accounts for contact pressure, sensor type, and overlying tissue above the artery in measured arterial pulse waveform (APW). While the arterial wall is treated as a 1-DOF unit, the tissue-contact-sensor (TCS) unit, formed by overlying tissue, sensor, and their contact interface, is treated as another 1-DOF unit. Measured APW from three types of sensors: a photoplethysmography (PPG) sensor, an accelerometer, and a tactile sensor, is theoretically related to dynamic parameters of the TCS unit. With pulsatile pressure at the radial artery as the true APW, the measured APW is calculated with different values of the dynamic parameters of the TCS unit. Due to its non-negligible damping and inertial terms, the TCS unit serves as a harmonics-dependent transfer function from the true APW to the measured APW. By determining dynamic parameters of the TCS unit, contact pressure, sensor type, and overlying tissue affect measured APW, and consequently the foot, peak, and other key features of measured APW. Natural frequency of the TCS unit plays a dominant role in affecting measured APW, as compared to its damping and spring stiffness. The myth of influence of transmural pressure on arterial wall elasticity stems from negative pulsatile forces from the TCS unit. Motion artifacts introduce not merely additive noise (or baseline drift) but also multiplicative noise to measured APW, and thus minimizing motion artifacts is crucial for improving accuracy in measured APW.
This paper, the second of two parts, presents an analytical model of motion artifacts (MA) in measured pulse signals by a tactile sensor, which contains a deformable microstructure sitting on a substrate. While the tissue-contact-sensor (TCS) stack and the sensor are both treated as a 1DOF (degree-of-freedom) system, tissue–sensor contact joins their mass together to form a 1DOF system with springs and dampers on both sides. MA on the sensor substrate causes baseline drift and time-varying system parameters (TVSP) of the TCS stack simultaneously. An analytical model is developed to mathematically relate baseline drift and TVSP to a measured pulse signal. The numerical calculation is conducted in MATLAB. Baseline drift in a measured pulse signal is much lower than the actual MA in its measurement. As compared to baseline drift, TVSP generates relatively abrupt, small distortion (e.g., 0.2% variation in heart rate and <5% change in pulse amplitude), but it rides on each harmonic of the true pulse signal. Sensor design alters both the deviation of the amplitude and waveform of a measured pulse signal from the true pulse signal and the influence of MA on it.