This paper, the second of two parts, presents an analytical model of motion artifacts (MA) in measured pulse signals by a tactile sensor, which contains a deformable microstructure sitting on a substrate. While the tissue-contact-sensor (TCS) stack and the sensor are both treated as a 1DOF (degree-of-freedom) system, tissue–sensor contact joins their mass together to form a 1DOF system with springs and dampers on both sides. MA on the sensor substrate causes baseline drift and time-varying system parameters (TVSP) of the TCS stack simultaneously. An analytical model is developed to mathematically relate baseline drift and TVSP to a measured pulse signal. The numerical calculation is conducted in MATLAB. Baseline drift in a measured pulse signal is much lower than the actual MA in its measurement. As compared to baseline drift, TVSP generates relatively abrupt, small distortion (e.g., 0.2% variation in heart rate and <5% change in pulse amplitude), but it rides on each harmonic of the true pulse signal. Sensor design alters both the deviation of the amplitude and waveform of a measured pulse signal from the true pulse signal and the influence of MA on it.
This paper, the first of two parts, presents an analytical model of motion artifacts (MAs) in measured pulse signals by accelerometers and photoplethysmography (PPG) sensors. As the transmission path from the true pulse signal in an artery to the sensor output (measured pulse signal), the tissue–contact–sensor (TCS) stack is modeled as a 1DOF (degree-of-freedom) system. MAs cause baseline drift of the mass and simultaneously time-varying system parameters (TVSPs) of the TCS stack. With arterial wall displacement and pulsatile pressure serving separately as the true pulse signal, an analytical model is developed to mathematically relate baseline drift and TVSP to a measured pulse signal. With assumed values of baseline drift and TVSPs, the numerical calculation is conducted in MATLAB. While baseline drift is low-frequency additive noise and can greatly swing a measured pulse signal, TVSP generates relatively small, abrupt distortion (e.g., 1% variation in heart rate and <5% change in pulse amplitude) but rides on each harmonic of the true pulse signal. By taking into account the full involvement of the transmission path in pulse measurement, this analytical model serves as a fundamental framework for quantifying baseline drift and TVSPs from a measured pulse signal in the future.
Motion artifacts (MA) cause great variability in a measured arterial pulse signal, and treatment of MA solely as a baseline drift (BD) fails to eliminate its effect on the measured signal. This paper presents a study on the effect of MA at rest (<0.7 Hz) on measured arterial pulse signals using a microfluidic-based tactile sensor. By taking full account of the dynamic behavior of the transmission path from the true pulse signal in an artery to a measured pulse signal at the sensor, the tissue-contact-sensor (TCS) stack, an analytical model of MA in a measured pulse signal is developed. In this model, the TCS stack is treated as a 1DOF system for its dynamic behavior; MA is quantified as the displacement (i.e., BD) and time-varying system parameters (TVSP) of the TCS stack. The mathematical expression of MA in a measured pulse signal reveals that while BD remains as low-frequency additive noise, TVSP causes time-varying harmonics in a measured pulse signal. Further time-frequency analysis (TFA) of measured pulse signals validates the existence of TVSP and, for the first time, reveals its effect on a measured pulse signal: time-varying amplitude in each harmonic and non-flat harmonic-MA-coupled baseline.
At-rest PPG signals have been explored for detecting atrial fibrillation (AF), yet current signal-processing techniques do not achieve perfect accuracy even under low-motion artifact (MA) conditions. This study evaluates the effectiveness of a single-degree-of-freedom time–frequency (SDOF-TF) method in analyzing at-rest PPG signals for AF detection. The method leverages the influence of MA on the instant parameters of each harmonic, which is identified using an SDOF model in which the tissue–contact–sensor (TCS) stack is treated as an SDOF system. In this model, MA induces baseline drift and time-varying system parameters. The SDOF-TF method enables the quantification and removal of MA and noise, allowing for the accurate extraction of the arterial pulse waveform, heart rate (HR), heart rate variability (HRV), respiration rate (RR), and respiration modulation (RM). Using data from the MIMIC PERform AF dataset, the method achieved 100% accuracy in distinguishing AF from non-AF cases based on three features: (1) RM, (2) HRV derived from instant frequency and instant initial phase, and (3) standard deviation of HR across harmonics. Compared with non-AF, the RM for each harmonic was increased by AF. RM exhibited an increasing trend with harmonic order in non-AF subjects, whereas this trend was diminished in AF subjects.
Influence of motion artifacts on instantaneous frequencybased heart rate variability of arterial pulse signals measured by a tactile sensor: an analytical study, Hasan, Mamun, Hao, Zhili Influence of motion artifacts on instantaneous frequencybased heart rate variability of arterial pulse signals measured by a tactile sensor: an analytical study, Hasan, Mamun, Hao, Zhili