12 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MRMd Mahfuzur Rahman
Md Mahfuzur Rahman
STSubodh Toraskar
Subodh Toraskar
MHMamun Hasan
Mamun Hasan
ZHZhili Hao
Zhili Hao
This paper, the first of two parts, presents an analytical model of motion artifacts (MAs) in measured pulse signals by accelerometers and photoplethysmography (PPG) sensors. As the transmission path from the true pulse signal in an artery to the sensor output (measured pulse signal), the tissue–contact–sensor (TCS) stack is modeled as a 1DOF (degree-of-freedom) system. MAs cause baseline drift of the mass and simultaneously time-varying system parameters (TVSPs) of the TCS stack. With arterial wall displacement and pulsatile pressure serving separately as the true pulse signal, an analytical model is developed to mathematically relate baseline drift and TVSP to a measured pulse signal. With assumed values of baseline drift and TVSPs, the numerical calculation is conducted in MATLAB. While baseline drift is low-frequency additive noise and can greatly swing a measured pulse signal, TVSP generates relatively small, abrupt distortion (e.g., 1% variation in heart rate and <5% change in pulse amplitude) but rides on each harmonic of the true pulse signal. By taking into account the full involvement of the transmission path in pulse measurement, this analytical model serves as a fundamental framework for quantifying baseline drift and TVSPs from a measured pulse signal in the future.

12 September 2025 in Sensors
Verified
Journal Article
Open access
PDF file
MRMd Mahfuzur Rahman
Md Mahfuzur Rahman
STSubodh Toraskar
Subodh Toraskar
MHMamun Hasan
Mamun Hasan
ZHZhili Hao
Zhili Hao
This paper, the second of two parts, presents an analytical model of motion artifacts (MA) in measured pulse signals by a tactile sensor, which contains a deformable microstructure sitting on a substrate. While the tissue-contact-sensor (TCS) stack and the sensor are both treated as a 1DOF (degree-of-freedom) system, tissue–sensor contact joins their mass together to form a 1DOF system with springs and dampers on both sides. MA on the sensor substrate causes baseline drift and time-varying system parameters (TVSP) of the TCS stack simultaneously. An analytical model is developed to mathematically relate baseline drift and TVSP to a measured pulse signal. The numerical calculation is conducted in MATLAB. Baseline drift in a measured pulse signal is much lower than the actual MA in its measurement. As compared to baseline drift, TVSP generates relatively abrupt, small distortion (e.g., 0.2% variation in heart rate and <5% change in pulse amplitude), but it rides on each harmonic of the true pulse signal. Sensor design alters both the deviation of the amplitude and waveform of a measured pulse signal from the true pulse signal and the influence of MA on it.

4 September 2025 in Biosensors
Verified
Journal Article
Open access
PDF file
MRMd Mahfuzur Rahman
Md Mahfuzur Rahman
MHMamun Hasan
Mamun Hasan
ZHZhili Hao
Zhili Hao
Motion artifacts (MA) cause great variability in a measured arterial pulse signal, and treatment of MA solely as a baseline drift (BD) fails to eliminate its effect on the measured signal. This paper presents a study on the effect of MA at rest (<0.7 Hz) on measured arterial pulse signals using a microfluidic-based tactile sensor. By taking full account of the dynamic behavior of the transmission path from the true pulse signal in an artery to a measured pulse signal at the sensor, the tissue-contact-sensor (TCS) stack, an analytical model of MA in a measured pulse signal is developed. In this model, the TCS stack is treated as a 1DOF system for its dynamic behavior; MA is quantified as the displacement (i.e., BD) and time-varying system parameters (TVSP) of the TCS stack. The mathematical expression of MA in a measured pulse signal reveals that while BD remains as low-frequency additive noise, TVSP causes time-varying harmonics in a measured pulse signal. Further time-frequency analysis (TFA) of measured pulse signals validates the existence of TVSP and, for the first time, reveals its effect on a measured pulse signal: time-varying amplitude in each harmonic and non-flat harmonic-MA-coupled baseline.

27 February 2026 in Medical Sensors & Imaging
Verified
Journal Article
Open access
MRMd Mahfuzur Rahman
Md Mahfuzur Rahman
MHMamun Hasan
Mamun Hasan
JMJennifer May
Jennifer May
JHJohn Milton Herre
John Milton Herre
LRLeryn Reynolds
Leryn Reynolds
ZHZhili Hao
Zhili Hao

31 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MRMd Mahfuzur Rahman
Md Mahfuzur Rahman
MHMamun Hasan
Mamun Hasan
JMJennifer May
Jennifer May
JHJohn Milton Herre
John Milton Herre
LRLeryn J. Reynolds
Leryn J. Reynolds
ZHZhili Hao
Zhili Hao
Aim: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can capture subject-specific physiological characteristics and longitudinal changes in patients with diverse heart diseases. Method: Arterial pulse signals at the radial artery (RA) and carotid artery (CA) were recorded using microfabricated tactile sensors and analyzed with a single-degree-of-freedom time–frequency (SDOF-TF) framework. Key CV parameters, including heart rate (HR), heart rate variability (HRV), respiration rate (RR), respiration modulation (RM), harmonic amplitudes, and normalized arterial pulse waveform (APW), were extracted from measurements at-rest and post-exercise across three visits in eighteen patients with heterogeneous CV conditions. Longitudinal changes in CV parameters within subjects and variability between subjects were assessed. Results: Compared to a healthy reference, patients exhibited altered CV profiles indicative of impaired autonomic regulation. Common trends included reduced HRV, blunted post-exercise CV responses, and attenuation of higher-order harmonics at the RA. CA-derived APW features showed enhanced sensitivity to systolic upstroke slope compared to the RA. Marked inter-subject variability was evident, reflected in at-rest values of key CV parameters and 5min post-exercise responses, highlighting the need for personalized interpretation. Longitudinal measurements revealed mixed effects of exercise on the CV system, likely influenced by concurrent medication and the short observation period. Conclusion: The SDOF-TF framework applied to arterial pulse signals effectively reveals both shared and individualized CV dysfunctions, capturing qualitative harmonic signatures, site-specific differences, and complex parameter interactions not detected by conventional methods, offering potential improvements in diagnosis and treatment monitoring for patients with diverse CV diseases.

31 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
MHMamun Hasan
Mamun Hasan
MRMd Mahfuzur Rahman
Md Mahfuzur Rahman
JMJennifer May
Jennifer May
JHJohn Milton Herre
John Milton Herre
LRLeryn Reynolds
Leryn Reynolds
ZHZhili Hao
Zhili Hao
Objectives: This study evaluates whether cardiovascular (CV) parameters derived from noninvasive arterial pulse signals can reveal subject-specific characteristics in patients with atypical CV dynamics that may be obscured in group-level analyses. Methods: Seven special-case patients—including a heart transplant (HTx) recipient and individuals with bradycardia (low heart rate), low dicrotic notch (DN), and intermittent arterial pulse waveform (APW) variations—were analyzed across three visits over the cardiac rehabilitation period. Radial artery (RA) and carotid artery (CA) signals, acquired using microfabricated tactile sensors, were processed using a single-degree-of-freedom time–frequency (SDOF–TF) framework to extract multiple CV parameters. Results: The patients exhibited highly heterogeneous CV profiles. Subjects with low heart rate (HR) demonstrated blunted post-exercise responses. Subjects with low DN morphology exhibited elevated lower-order harmonic amplitudes. Patients with intermittent features showed cyclic variations in APW morphology at-rest and during post-exercise recovery. Across all cases, RA measurements generally provided more stable and interpretable individualized patterns across visits, whereas CA measurements were more susceptible to variability related to motion artifacts (MA) and sensor-artery interaction effects. Conclusions: The SDOF–TF framework successfully identifies individualized multi-parameter CV characteristics associated with diverse complex CV conditions of the seven cases. The findings support the potential value of individualized arterial pulse analysis for personalized CV monitoring and indicate that post-exercise assessment provides more distinctive characterization of CV dynamics than conventional at-rest analysis alone.