Martin Peter Lipus

Dr. Martin Peter Lipus

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 February 2021 in Geothermal Energy
Verified
Journal Article
Open access
PDF file
MLMartin Peter Lipus
Martin Peter Lipus
TRThomas Reinsch
Thomas Reinsch
TWTobias B. Weisenberger
Tobias B. Weisenberger
SKSteinar Kragset
Steinar Kragset
ASAri Stefánsson
Ari Stefánsson
SBSigurdur G. Bogason
Sigurdur G. Bogason
Cementing operations in wellbores, especially for long casings, are often challenging and prone to deficiencies when not properly planned and executed. While exploring for and exploiting of geothermal resources at temperatures above the critical point of water was attempted in different drilling projects in recent years, the well design, and especially the procedure to run and cement long production casings became a key challenge for drilling engineers. For the first time, a reverse cementing job for a 2.97 km long production casing in a high-temperature geothermal well could be monitored and analyzed using a combination of permanently installed distributed fiber optic and electronic sensors as well as conventional well logging equipment. Data from the permanently installed sensors were used to monitor and evaluate the cementation process as well as the onset of the cement hydration. Based on the data, the understanding of downhole fluid dynamics during cementation could be improved. Our analysis suggests that the cement was diluted during cement placement and partly lost into the formation. These findings can help to better prepare for future drilling ventures under similar downhole conditions.

19 January 2022 in Solid Earth
Verified
Journal Article
Open access
PDF file
MLMartin Peter Lipus
Martin Peter Lipus
FSFelix Schölderle
Felix Schölderle
TRThomas Reinsch
Thomas Reinsch
CWChristopher Wollin
Christopher Wollin
CKCharlotte Krawczyk
Charlotte Krawczyk
KZKai Zosseder
Kai Zosseder
Fiber-optic distributed acoustic sensing (DAS) data find many applications in wellbore monitoring such as flow monitoring, formation evaluation and well integrity studies. For horizontal or highly deviated wells, wellbore fiber-optic installations can be conducted by mounting the sensing cable to a rigid structure (casing/tubing) which allows for a controlled landing of the cable. We analyze a cold-water injection phase in a geothermal well with a 3.6 km long fiber-optic installation mounted to a 3/4 in. sucker rod by using both DAS and distributed temperature sensing (DTS) data. During cold-water injection, we observe distinct vibrational events (shock waves) which originate in the reservoir interval and migrate up- and downwards. We use temperature differences from the DTS data to determine the theoretical thermal contraction and integrated DAS data to estimate the actual deformation of the rod construction. The results suggest that the rod experiences thermal stresses along the installation length – partly in the compressional and partly in the extensional regime. We find strong evidence that the observed vibrational events originate from the release of the thermal stresses when the friction of the rod against the borehole wall is overcome. Within this study, we show the influence of temperature changes on the acquisition of distributed acoustic/strain sensing data along a fiber-optic cable suspended along a rigid but freely hanging rod. We show that observed vibrational events do not necessarily originate from induced seismicity in the reservoir but instead can originate from stick–slip behavior of the rod construction that holds the measurement equipment.

6 July 2021 in EGUsphere
Verified
Preprint
Open access
PDF file
MLMartin Peter Lipus
Martin Peter Lipus
FSFelix Schölderle
Felix Schölderle
TRThomas Reinsch
Thomas Reinsch
CWChristopher Wollin
Christopher Wollin
CKCharlotte M. Krawczyk
Charlotte M. Krawczyk
KZKai Zosseder
Kai Zosseder
Fiber-optic distributed acoustic sensing (DAS) data finds many applications in wellbore monitoring such as e.g. flow monitoring, formation evaluation, and well integrity studies. For horizontal or highly deviated wells, wellbore fiber-optic installations can be conducted by mounting the sensing cable to a rigid structure (casing/tubing) which allows for a controlled landing of the cable. We analyze a cold-water injection phase in a geothermal well with a 3.6 km long fiber-optic installation mounted to a ¾” sucker-rod by using both DAS and distributed temperature sensing (DTS) data. During cold-water injection, we observe distinct vibrational events (shock waves) which originate in the reservoir interval and migrate up- and downwards. We use temperature differences from the DTS data to determine the theoretical thermal contraction and integrated DAS data to estimate the actual deformation of the rod construction. The results suggest that the rod experiences thermal stresses along the installation length – partly in the compressional and partly in the extensional regime. We find strong evidence that the observed vibrational events originate from the release of the thermal stresses when the friction of the rod against the borehole wall is overcome. Within this study, we show the influence of temperature changes on the acquisition of distributed acoustic/strain sensing data along a fiber-optic cable suspended along a rigid but freely hanging rod. We show that observed vibrational events do not necessarily originate from induced seismicity in the reservoir, but instead, can originate from stick-slip behavior of the rod construction that holds the measurement equipment.

15 May 2023
Verified
Conference Paper
Open access
CWChristopher Wollin
Christopher Wollin
LELeila Ehsaninezhad
Leila Ehsaninezhad
JHJohannes Hart
Johannes Hart
MLMartin Peter Lipus
Martin Peter Lipus
CKCharlotte Krawczyk
Charlotte Krawczyk
Seismic microzonation and ambient noise tomography via Distributed Acoustic Sensing (DAS) may contribute to the seismic hazard assessment and the exploration or monitoring of utilizable and utilised subsurface volumes at favorable costs. However, numerous technical aspects remain under investigation to further maturate this innovative seismological approach – particularly when applied to dark telecommunication fibers. For instance unknown coupling of the fiber to the ground or presence of loops of slack fiber may disturb the regular measuring of the stringed virtual sensors. In this study, we investigate how loops of slack fiber affect the results of passive ambient tomography, a particularly appealing exploration approach due to its low footprint. We present results obtained with DAS recordings on purposefully installed as well as dark telecommunication optic fiber. Sledgehammer blows were recorded on an optic fiber laid out in an urban heating tunnel before and after introducing several loops of slack. The loops coiled up fractions and multiples of the utilized gauge length and were spaced in sufficient distance to independently analyze the surrounding wavefield. Discontinuous wavefronts can be observed once the coiled fiber exceeds the gauge length. Similar observations were made on the virtual shot gathers calculated along a 4.5 km long segment of dark fiber along a major road in the city of Berlin, Germany. We show how the loops of slack affect the further processing with respect to ambient noise tomography. On average, the removal of virtual sensors identified to be located in coiled fiber reduces the shear-wave velocities in the resulting model. We conclude that the careful removal of virtual sensors within loops of slack is a mandatory processing step towards ambient noise tomography with linear DAS arrays. However, the calculation of virtual shot gathers can help to reveal the affected fiber segments.

20 September 2021
Verified
Other
Open access
PDF file
MLMartin Peter Lipus
Martin Peter Lipus
FSFelix Schölderle
Felix Schölderle
TRThomas Reinsch
Thomas Reinsch
CWChristopher Wollin
Christopher Wollin
CKCharlotte M. Krawczyk
Charlotte M. Krawczyk
KZKai Zosseder
Kai Zosseder
Fiber-optic distributed acoustic sensing (DAS) data finds many applications in wellbore monitoring such as e.g. flow monitoring, formation evaluation, and well integrity studies. For horizontal or highly deviated wells, wellbore fiber-optic installations can be conducted by mounting the sensing cable to a rigid structure (casing/tubing) which allows for a controlled landing of the cable. We analyze a cold-water injection phase in a geothermal well with a 3.6 km long fiber-optic installation mounted to a ¾” sucker-rod by using both DAS and distributed temperature sensing (DTS) data. During cold-water injection, we observe distinct vibrational events (shock waves) which originate in the reservoir interval and migrate up- and downwards. We use temperature differences from the DTS data to determine the theoretical thermal contraction and integrated DAS data to estimate the actual deformation of the rod construction. The results suggest that the rod experiences thermal stresses along the installation length – partly in the compressional and partly in the extensional regime. We find strong evidence that the observed vibrational events originate from the release of the thermal stresses when the friction of the rod against the borehole wall is overcome. Within this study, we show the influence of temperature changes on the acquisition of distributed acoustic/strain sensing data along a fiber-optic cable suspended along a rigid but freely hanging rod. We show that observed vibrational events do not necessarily originate from induced seismicity in the reservoir, but instead, can originate from stick-slip behavior of the rod construction that holds the measurement equipment.

20 January 2025
Verified
Conference Paper
Open access
JHJohannes Hart
Johannes Hart
BPBerker Polat
Berker Polat
FSFelix Schölderle
Felix Schölderle
TLToni Ledig
Toni Ledig
MLMartin Peter Lipus
Martin Peter Lipus
CKCharlotte Krawzcyk
Charlotte Krawzcyk
Reliable well completion technologies are mandatory for the safe and sustainable use of subsurface reservoirs. Achieving subsurface well integrity requires displacing the entire drilling mud with homogenous cement. For this purpose, surface pump parameters (rate, density, pressure, and volume) are generally measured, yielding average values along the borehole. Here, distributed fiber-optic sensing offers new continuous monitoring options with dense spatial sampling within a borehole.In the GFK-monitor project (https://gfk-monitor.de/en/), we investigated the primary cementation of an 874 m surface casing at a geothermal well in Munich, Germany. A 699 m long fiber optic cable, implemented by the Geothermie Allianz Bayern (GAB), was attached to the outside of the casing in the annulus between the casing and formation and cemented. This allowed for monitoring distributed dynamic strain rate (DDSS or DAS) throughout cement placement with a sampling rate of 1000 Hz and a spatial resolution of 1 m.We analyzed the average vibration energy in the borehole by DDSS data using a root mean square approach in rolling windows for different frequency bands. Linear features with two different characteristics appear prominently in the frequency band between 0.2-0.3 Hz. One feature, which we named the “slow feature”, shows a varying slope resulting in velocities ranging from 2.5 to 6 m/s. In contrast, the accordingly called “fast feature” indicates a relatively constant velocity of around 6 m/s.To better understand these features, a theoretical model was developed that simulates the rising velocity of fluids along the annulus. This model uses a cumulative approach and considers the cement pumping rate, borehole geometry, and timings from the daily reports. We assume, that the predicted minimum velocity is required to fill the whole breakout volume. This means that the faster the velocity the smaller the flow paths cross section.A comparison of data and models reveals that the varying velocities of the "slow feature" correlate with velocities predicted by using the borehole geometry from the caliper log. The rather constant “fast feature” correlates instead with the predicted velocity of the model based on a uniform borehole geometry with the smallest possible radius, the drill diameter, which thus neglects all breakouts.In summary, due to the nearly constant pumping rate during the monitoring campaign, we hypothesize that different rising velocities result from variations in the cross-sectional area of the flow path. Based on our observations, the majority of the water spacer does not flush the borehole breakouts. With a good match to the minimum required velocity, these breakouts are filled by the first arriving cement. The following cement, with the same density, rises again on the fastest track. Thus, measuring the cement rising velocities with fiber optics and comparing them to the minimum required velocity from modeling might be a new tool to assess displacement efficiency in real-time.