Johannes Hart

Johannes Hart

Auto-generated profile, based on publicly available information

Johannes Hart

GFZ Helmholtz Centre for Geosciences

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2025
Verified
Conference Paper
Open access
JHJohannes Hart
Johannes Hart
BPBerker Polat
Berker Polat
FSFelix Schölderle
Felix Schölderle
TLToni Ledig
Toni Ledig
MLMartin Peter Lipus
Martin Peter Lipus
CKCharlotte Krawzcyk
Charlotte Krawzcyk
Reliable well completion technologies are mandatory for the safe and sustainable use of subsurface reservoirs. Achieving subsurface well integrity requires displacing the entire drilling mud with homogenous cement. For this purpose, surface pump parameters (rate, density, pressure, and volume) are generally measured, yielding average values along the borehole. Here, distributed fiber-optic sensing offers new continuous monitoring options with dense spatial sampling within a borehole.In the GFK-monitor project (https://gfk-monitor.de/en/), we investigated the primary cementation of an 874 m surface casing at a geothermal well in Munich, Germany. A 699 m long fiber optic cable, implemented by the Geothermie Allianz Bayern (GAB), was attached to the outside of the casing in the annulus between the casing and formation and cemented. This allowed for monitoring distributed dynamic strain rate (DDSS or DAS) throughout cement placement with a sampling rate of 1000 Hz and a spatial resolution of 1 m.We analyzed the average vibration energy in the borehole by DDSS data using a root mean square approach in rolling windows for different frequency bands. Linear features with two different characteristics appear prominently in the frequency band between 0.2-0.3 Hz. One feature, which we named the “slow feature”, shows a varying slope resulting in velocities ranging from 2.5 to 6 m/s. In contrast, the accordingly called “fast feature” indicates a relatively constant velocity of around 6 m/s.To better understand these features, a theoretical model was developed that simulates the rising velocity of fluids along the annulus. This model uses a cumulative approach and considers the cement pumping rate, borehole geometry, and timings from the daily reports. We assume, that the predicted minimum velocity is required to fill the whole breakout volume. This means that the faster the velocity the smaller the flow paths cross section.A comparison of data and models reveals that the varying velocities of the "slow feature" correlate with velocities predicted by using the borehole geometry from the caliper log. The rather constant “fast feature” correlates instead with the predicted velocity of the model based on a uniform borehole geometry with the smallest possible radius, the drill diameter, which thus neglects all breakouts.In summary, due to the nearly constant pumping rate during the monitoring campaign, we hypothesize that different rising velocities result from variations in the cross-sectional area of the flow path. Based on our observations, the majority of the water spacer does not flush the borehole breakouts. With a good match to the minimum required velocity, these breakouts are filled by the first arriving cement. The following cement, with the same density, rises again on the fastest track. Thus, measuring the cement rising velocities with fiber optics and comparing them to the minimum required velocity from modeling might be a new tool to assess displacement efficiency in real-time.

18 March 2025
Verified
Conference Paper
Open access
JHJohannes Hart
Johannes Hart
CWChristopher Wollin
Christopher Wollin
AAAurelio Andy
Aurelio Andy
TLToni Ledig
Toni Ledig
TRThomas Reinsch
Thomas Reinsch
CKCharlotte Krawczyk
Charlotte Krawczyk
Geothermal productivity strongly depends on reservoir performance, which is regularly monitored. This work presents the results from Distributed Dynamic Strain Sensing (DDSS or DAS) measurements during the restart of injection and production in deep geothermal wells. This technology's high spatiotemporal resolution enables monitoring relative strain and temperature changes along the entire sensing cable. We monitored 3.7 km of a producer and approximately 4.1 km of an injector. Both cables were installed post-borehole completion and reached up to 1 km into the reservoir. Distributed sensing was achieved using a commercial DDSS acquisition system sampling the boreholes at 1 m spatial interval and 2000 Hz.Here, we focus on the low-frequency subsurface dynamics captured during the restart phase. We extracted the low-frequency content (

4 October 2025
Verified
Book Chapter
Open access
PDF file
MLMartin Peter Lipus
Martin Peter Lipus
JHJohannes Hart
Johannes Hart
CWChristopher Wollin
Christopher Wollin
CKCharlotte M. Krawczyk
Charlotte M. Krawczyk
PMPeter Mock
Peter Mock
BWBastian Wacker
Bastian Wacker
Infrastructure operators such as the Autobahn GmbH of the Federal Government in Germany depend on being able to use as much information as possible about the existing infrastructure for planning and maintenance. In addition to the existing non-destructive measurements, monitoring with sensor technology built into the infrastructure can also provide useful information for efficient maintenance planning. As part of a feasibility study, various setups of new developments in fiber-optic sensors were installed in a rehabilitated autobahn section in order to investigate traffic-related information as well as long-term integrity. In addition to temperature monitoring during the road construction, strain and acoustic measurements were recorded and evaluated during defined crossings of traffic. The preliminary results show that traffic relevant information such as the counting of passing vehicles, their velocity, vehicle type and axle load can be derived from the fiber-optic data. Furthermore, the results suggest that relevant parameters about the elastic properties of the roadwork (Young’s Modulus and material fatigue) can be extracted. At the present time, considerable efforts are still required for data preparation and data analysis to apply this monitoring technology permanently. This is the objective of the current and future development stages.

14 March 2026
Verified
Conference Paper
Open access
JHJohannes Hart
Johannes Hart
CWChristopher Wollin
Christopher Wollin
AAAurelio Andy
Aurelio Andy
TLToni Ledig
Toni Ledig
TRThomas Reinsch
Thomas Reinsch
CKCharlotte Krawczyk
Charlotte Krawczyk
High-resolution diagnostics of flow and heat transfer in deep geothermal wells are commonly constrained by sparse downhole instrumentation and production-logging tools that require well intervention, interrupting steady-state operations. Here, we demonstrate continuous flow profiling and convection-regime identification (pump-driven forced convection vs. buoyancy-driven natural convection) using fiber-optic sensing methods. We used a combination of the Low-Frequency Distributed Acoustic Sensing (LF-DAS) approach, which measures axial strain-rate changes along a fiber, and Distributed Temperature Sensing (DTS) in a 4.1 km MD (Measured Depth) geothermal injection well within Munich, Germany.During shut-in, LF-DAS reveals three persistent, depth-localized natural convection cells, characterized by distinct strain-rate patterns and coincident with rapid warming with depth, as observed in the DTS data. In quasi-steady-state injection, operationally occurring temperature changes as small as 10 mK/min in the injected fluid induce thermo-mechanical deformation along the fiber. These downward-propagating thermal fronts initially reflect pump-driven forced convection and enable flow profiling based on advective heat transport. From a depth of 3580 m MD, these fronts are blurred by the onset of buoyancy-driven natural convection. LF-DAS allows estimation of the plume-shedding frequency, plume height, travel distance, and velocity, all related to the temperature gradient measured with DTS. The accuracy of a threshold criterion for the onset of buoyancy-driven flow based on the temperature gradient is currently limited by the precision of the reference DTS measurement. Across all operational states, values range from 39 to 44 °C/km of true vertical depth.These findings show that fiber-optic sensing can detect fluid-flow pathways, convection behavior, and regime changes without well intervention, thereby improving continuous monitoring and reservoir characterization for sustainable geothermal operation.

15 March 2025
Verified
Conference Paper
Open access
MKMartin Knapmeyer
Martin Knapmeyer
BKBrigitte Knapmeyer-Endrun
Brigitte Knapmeyer-Endrun
MMMichael Maibaum
Michael Maibaum
CFCinzia Fantinati
Cinzia Fantinati
MHMaria Hallinger
Maria Hallinger
CSCarl Spichal
Carl Spichal
The current renaissance in lunar exploration, driven by space agencies as well as the private sector, requires suitable test and training facilities on Earth to proceed in a safe and sustainable manner. To address this need, DLR and ESA have opened the Moon analogue facility LUNA in Cologne, Germany, in September 2024. We will provide an overview of LUNA and report on first campaigns, which already included usage by universities, national space agencies, and the private sector.At the heart of LUNA is a 700 m² regolith hall, filled with Mare simulant EAC-1A to 60 cm depth. With black walls, a preliminary sun simulator allowing to simulate illumination at the lunar south polar region, geologically relevant rocks, an Argonaut lunar lander mock-up, two 3U-rovers that might carry individual instruments, and a future gravity offloading, LUNA simulates the lunar surface and allows to test the operations of instruments and experiments on the Moon as well as train operations for robotic and crewed lunar missions. A dedicated ground segment permits commanding and telemetry and data exchange under mission-like conditions. Further outfitting by elements both within (e.g. a ramp to simulate slopes of at least up to 40 deg) and outside of LUNA (e.g. Flexhab habitat, EDEN-LUNA greenhouse) is ongoing.The deep floor area (DFA), with a regolith depth of up to 3 m over an area of approximately 135m² and two sloping walls with angles of 25° and 40°, allows for testing geophysical exploration methods as well as drilling and sampling techniques. The initial outfitting of the DFA includes two buried metal reference targets for ground-penetrating radar (GPR), as well as a small simulated lava tunnel at the bottom, constructed from concrete and expanded foam sheets. Additionally, PMMA (aka Plexiglas™) is used to simulate the elastic and dielectric contrasts between regolith and ice, which is of special interest in exploration of the lunar South Pole, and emplaced to mimic both a thin ice horizon as well as distributed veins of ice (reticular chaotic cryostructure, formed by 1000 PMMA discs). A fiber-optic cable, including fibers for distributed temperature sensing (DTS), distributed acoustic sensing (DAS), and an engineered fiber, has been buried throughout the hall to be used for background data, and a broad-band seismometer has been installed permanently in LUNA. Several seismic reference measurements as well as a GPR test have been conducted to characterize the LUNA hall and environment.The EAC-1A simulant has been characterized in terms of elastic, electric and thermal properties, e.g. seismic wave velocities and attenuation from resonant column tests, dielectric permittivity and loss tangent, and thermal conductivity. We show in how far these parameters match the values for actual lunar regolith. We will also report on first test campaigns, e.g. regarding geophones and the engineered DAS fibre, GPR, and rover navigation.

6 May 2024
Verified
Conference Paper
Open access
JHJohannes Hart
Johannes Hart
BPBerker Polat
Berker Polat
FSFelix Schölderle
Felix Schölderle
TLToni Ledig
Toni Ledig
MLMartin Lipus
Martin Lipus
CKCharlotte Krawczyk
Charlotte Krawczyk
Geothermal reservoirs require reliable well-completion techniques to reach well integrity. Well, integrity means there are no flow paths behind the casing at all. While constructing the well, the drilling mud must be fully displaced by uncontaminated cement, measured in displacement efficiency. Conventional real-time measurements show average pumping parameters to control the cement job's success. However, studies show issues with well integrity worldwide. We aim to improve well integrity by closing an information gap within the construction phase using continuous distributed fiber-optic sensing with dense spatial sampling. This study investigated the primary cementing of an 874 m surface casing in Munich, Germany. A fiber optic cable deployed behind the casing enabled the measurement of distributed dynamic strain rate (DDSS or DAS) and distributed temperature (DTS) during cement placement. We used field data from the cementing service, developed a fluid displacement model, and compared the results with those of the fiber optics. While we can trace only the rise of a cold front in the temperature data, the combined interpretation of DAS data shows features that allow comprehensive insights into the subsurface displacement process. We observed two rising velocities at a constant pumping rate. We were able to correlate them to the rise of different fluid interfaces. We conclude that the freshwater spacer does not displace the drilling mud but the first arrival of cement. Once the breakouts are filled, the succeeding cement seeks the path of least resistance without displacing cement in the breakouts again. Our findings suggest the possibility of tracking the rise of different fluids and the stability of their interfaces in real-time with distributed dynamic strain sensing. Having sensors along the borehole to track the displacement efficiency enables on-site reactions to ensure the cement jobs' success.