Stefania Degli Abbati

Dr. Stefania Degli Abbati

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 November 2021 in Engineering Structures
Verified
Journal Article
Closed access
MAMICHELE ANGIOLILLI
MICHELE ANGIOLILLI
Sergio  LagomarsinoSergio Lagomarsino
Sergio Lagomarsino
Serena  CattariSerena Cattari
Serena Cattari
Stefania Degli AbbatiStefania Degli Abbati
Stefania Degli Abbati

18 June 2021 in Earthquake Engineering & Structural Dynamics
Verified
Journal Article
Open access
PDF file
Serena  CattariSerena Cattari
Serena Cattari
Stefania Degli AbbatiStefania Degli Abbati
Stefania Degli Abbati
SASara Alfano
Sara Alfano
ABAndrea Brunelli
Andrea Brunelli
FLFilippo Lorenzoni
Filippo Lorenzoni
FPFrancesca da Porto
Francesca da Porto
The construction of reliable numerical models is a key aspect within the seismic assessment of existing unreinforced masonry buildings. However, it is also a complex process due to the many uncertainties involved that can affect the structural response. In situ tests allow for the acquisition of data at a local scale. Nonetheless, supplementary information representing the global response is necessary to overcome other uncertainties (i.e., wall‐to‐wall connections or floor stiffness). To this end, data from ambient vibration tests (AVT) are useful to support seismic assessments. In fact, they allow for the identification of dynamic structural properties, which are useful in refining the calibration of numerical models. In addition, they address solutions for the aforementioned uncertainties. In this context, the paper presents how to efficiently exploit AVT data by using the case study of the former Courthouse of Fabriano (Ancona, Marche). This structure has been monitored since 2010 by the Italian Department of Civil Protection with a network of 28 seismic accelerometers. As a result, the equivalent frame (EF) model was calibrated in the linear field thanks to the dynamic identification provided under operational conditions. Subsequently, nonlinear dynamic analyses were performed using the recordings acquired during the Central Italy earthquake in 2016/2017. Even if the building experienced only a slight nonlinear behaviour, this comparison between the simulated and actual seismic response made it possible to validate the EF model, especially with reference to the capability in reproducing the amplification phenomena, which is extremely important for the assessment of structural and non‐structural components.

15 June 2021 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
Stefania Degli AbbatiStefania Degli Abbati
Stefania Degli Abbati
PMPaolo Morandi
Paolo Morandi
Serena  CattariSerena Cattari
Serena Cattari
ESENRICO SPACONE
ENRICO SPACONE
This paper presents the comparison of the results of modal and nonlinear analyses carried out on a 2-story masonry building with rigid diaphragms, inspired by the Pizzoli’s town hall (AQ, Italy). The case study is one of the Benchmark Structures (labeled BS6) in the “URM nonlinear modelling–Benchmark project” funded by the Italian Department of Civil Protection (DPC) within the framework of the ReLUIS projects. The building has been instrumented since 2009 with a permanent monitoring system by the Osservatorio Sismico delle Strutture (OSS) of the DPC and was hit by the 2016/2017 Central Italy earthquake sequence. In the research first phase, modal and nonlinear static analyses were carried out in a blind prediction, without any preliminary calibration of the models, but referring only to commonly made assumptions on materials and modelling. Five computer programs based on the Equivalent Frame Model (EFM) approach were used. Four different structural configurations were considered: with weak spandrels (A), with tie rods coupled to spandrels (B), with RC ring beams coupled to spandrels (C) and with “shear type” idealization (D). In the research second phase, two of the developed EFMs were calibrated in the elastic range using the results of available Ambient Vibration Tests (AVTs). The models were then validated in the nonlinear range by simulating the dynamic response of the structure recorded during the mainshocks of the 2016/2017 Central Italy earthquake. Recorded and numerical results were compared at both the global and local scale.

7 June 2023 in Journal of Civil Structural Health Monitoring
Verified
Journal Article
Open access
PDF file
Stefania Degli AbbatiStefania Degli Abbati
Stefania Degli Abbati
Daniele SivoriDaniele Sivori
Daniele Sivori
Serena  CattariSerena Cattari
Serena Cattari
Sergio  LagomarsinoSergio Lagomarsino
Sergio Lagomarsino
Post-earthquake damage surveys systematically highlight the seismic vulnerability of monumental structures, calling for simple assessment procedures to address the design of effective retrofitting interventions. The structural complexity characterizing monumental structures, however, makes a reliable prediction of their seismic response a relevant challenge of engineering interest. Ambient vibration tests (AVTs) provide valuable support to achieve such a task, improving the knowledge of the actual dynamic behavior of the structure and, consequently, the reliability of the seismic assessment. In this context, the paper illustrates the integration of AVTs outcomes with the evaluation of the seismic performance of historic masonry structures by presenting the comprehensive application to a case study, the bell tower of the Saint Lawrence’s Cathedral in Genoa, Italy. The research combines the assessment of the global seismic response of the tower, investigated through a simplified mechanical model, with the local verification of the pinnacles placed at its top, referring to a displacement-based approach on a macro-block model. An extensive ambient vibrations measurement campaign carried out in May 2020 allowed for a comprehensive operational identification of the bell tower and its pinnacles, clarifying the ongoing dynamic interaction with the main body of the church. This valuable information was successfully employed, first, to accurately reproduce the actual constraint conditions induced by the church on the bell tower, a determining factor in the modeling of its global seismic response and, second, to reliably quantify the seismic amplification caused by the tower filtering effect to be used as the seismic input for the local verification of the pinnacles.

12 June 2014 in Bulletin of Earthquake Engineering
Verified
Journal Article
Closed access
PDF file
Chiara CalderiniChiara Calderini
Chiara Calderini
Stefania Degli AbbatiStefania Degli Abbati
Stefania Degli Abbati
PCPatricia Cotič
Patricia Cotič
MKMeta Kržan
Meta Kržan
VBVlatko Bosiljkov
Vlatko Bosiljkov

9 July 2021 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
CMCarlo Filippo Manzini
Carlo Filippo Manzini
DODaria Ottonelli
Daria Ottonelli
Stefania Degli AbbatiStefania Degli Abbati
Stefania Degli Abbati
CMCorrado Marano
Corrado Marano
ECEmilia Angela Cordasco
Emilia Angela Cordasco
The paper presents the comparison of the results of non-linear static analyses performed with different software based on the equivalent frame (EF) modelling approach on a simple two-story unreinforced masonry building with rigid diaphragms. This study is part of a wider research activity carried out in the framework of the Italian Network of Seismic Laboratories (ReLUIS) projects, funded by the Italian Department of Civil Protection. Different configurations have been considered varying the layout of the openings on the bearing walls and the structural details. The EF models have been defined adopting as much as possible common assumptions, in order to reduce the epistemic modelling uncertainties and to facilitate the interpretation of the differences in the results obtained by the software. The comparison involved different aspects: the global scale response, in terms of capacity curves, the predicted damage pattern as well as checks at the local scale, in terms of distribution of the generalized forces. Moreover, in order to assess the reliability of the obtained results, the numerical predictions have been compared to an analytical upper bound reference solution. Finally, the sensitivity of the numerical response to the criterion adopted for the EF idealization of masonry walls has been investigated.