Daria Ottonelli

Daria Ottonelli

Auto-generated profile, based on publicly available information

Daria Ottonelli

CIMA Research Foundation, via Armando Magliotto 2, 17100, Savona, Italy

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2019 in Computers & Structures
Verified
Journal Article
Closed access
SAStefania Degli Abbati
Stefania Degli Abbati
ADAntonio Maria D'altri
Antonio Maria D'altri
DODaria Ottonelli
Daria Ottonelli
Giovanni CastellazziGiovanni Castellazzi
Giovanni Castellazzi
Serena  CattariSerena Cattari
Serena Cattari
Sergio  LagomarsinoSergio Lagomarsino
Sergio Lagomarsino

1 November 2022 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
Marco Di LudovicoMarco Di Ludovico
Marco Di Ludovico
Serena  CattariSerena Cattari
Serena Cattari
Gerardo Mario VerderameGerardo Mario Verderame
Gerardo Mario Verderame
CVCiro Del Vecchio
Ciro Del Vecchio
DODaria Ottonelli
Daria Ottonelli
Sergio  LagomarsinoSergio Lagomarsino
Sergio Lagomarsino
Recent seismic events worldwide have demonstrated the high vulnerability of existing school buildings and the urgent need to have reliable tools for the rapid seismic performance assessment and damage and loss quantification. Indeed, the significant damage observed on structural and non-structural components may have a significant impact in terms of direct and indirect losses making critical the recovery of stricken communities. Although a significant amount of work has been done in developing fragility curves for the residential building stock, only few contributions clearly refer to school buildings that significantly differ in terms of the main characteristics from the residential ones. This research work proposes fragility curves for reinforced concrete and unreinforced masonry public school buildings typical of the Italian building stock, based on the damage observed in the aftermath of the 2009 L’Aquila earthquake. A comprehensive and unique database including data on damaged and undamaged school buildings (2037 records) in the Abruzzo region was built using data from four different sources. Due to limited amount of data, the fragility curves can be very sensitive to the method adopted for their derivation, thus three different approaches (i.e. empirical, empirical-binomial, heuristic) are considered in the paper and the results are compared. Finally, a direct comparison with fragility curves available in the literature for the Italian residential building stock is presented.

18 January 2024 in International Journal of Disaster Risk Reduction
Verified
Journal Article
Open access
Maria PoleseMaria Polese
Maria Polese
GTGabriella Tocchi
Gabriella Tocchi
ABAnže Babič
Anže Babič
MDMatjaž Dolšek
Matjaž Dolšek
MFMarta Faravelli
Marta Faravelli
APAndrea Prota
Andrea Prota

16 August 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
GTGabriella Tocchi
Gabriella Tocchi
DODaria Ottonelli
Daria Ottonelli
NRNicola Rebora
Nicola Rebora
Maria PoleseMaria Polese
Maria Polese
Effective disaster risk management in a given area relies on the analysis of all relevant risks potentially affecting it. A proper multi-risk evaluation requires the ranking of analyzed risks and the estimation of overall expected impacts, considering possible hazards (and vulnerabilities) interactions as well. Due to their complex and challenging modelling, such interactions are usually neglected, and the analysis of risks derived from different sources are commonly performed through independent analysis. However, often the assessment procedures adopted for the analysis as well as the metrics used to express various risks are different, making results of single risk analyses hardly comparable. To overcome this issue, an approach that allows for comparing and ranking risks is presented in this study. The approach is demonstrated through an application for an Italian region. Earthquakes and floods are the investigated hazards. First, in order to select the case study area, the municipalities within the Veneto region where both risks could be highest are identified by adopting an index-based approach. Then, the harmonization of seismic and flood risk assessment procedure is performed. Sub-municipal areas are selected as scale of analysis and direct economic losses are chosen as common impact metrics. The results of the single risk analyses are compared using risk curves as standardization tool. The EAL (expected annual losses) are estimated through risk curves and the ratios between EAL due to floods and earthquakes are mapped, showing in which area risk is significantly higher than the other.

9 July 2021 in Bulletin of Earthquake Engineering
Verified
Journal Article
Open access
PDF file
CMCarlo Filippo Manzini
Carlo Filippo Manzini
DODaria Ottonelli
Daria Ottonelli
Stefania Degli AbbatiStefania Degli Abbati
Stefania Degli Abbati
CMCorrado Marano
Corrado Marano
ECEmilia Angela Cordasco
Emilia Angela Cordasco
The paper presents the comparison of the results of non-linear static analyses performed with different software based on the equivalent frame (EF) modelling approach on a simple two-story unreinforced masonry building with rigid diaphragms. This study is part of a wider research activity carried out in the framework of the Italian Network of Seismic Laboratories (ReLUIS) projects, funded by the Italian Department of Civil Protection. Different configurations have been considered varying the layout of the openings on the bearing walls and the structural details. The EF models have been defined adopting as much as possible common assumptions, in order to reduce the epistemic modelling uncertainties and to facilitate the interpretation of the differences in the results obtained by the software. The comparison involved different aspects: the global scale response, in terms of capacity curves, the predicted damage pattern as well as checks at the local scale, in terms of distribution of the generalized forces. Moreover, in order to assess the reliability of the obtained results, the numerical predictions have been compared to an analytical upper bound reference solution. Finally, the sensitivity of the numerical response to the criterion adopted for the EF idealization of masonry walls has been investigated.

8 June 2020 in Journal of Earthquake Engineering
Verified
Journal Article
Closed access
DODaria Ottonelli
Daria Ottonelli
Serena  CattariSerena Cattari
Serena Cattari
Sergio  LagomarsinoSergio Lagomarsino
Sergio Lagomarsino
In the framework of the evaluation of the consequences of an earthquake, the paper provides a procedure for the economic loss assessment in unreinforced masonry (URM) buildings, proposing an analytical approach based on a cost function directly dependent on the damage level associated to different structural elements and identified by specific engineering demand parameters. The procedure follows a component-based approach, to be implemented within modern probabilistic seismic risk analyses, and it includes both the in-plane and out-of-plane damage modes that can be activated in a URM structure. It is applied to a three-storey building, examined varying some configurations of structural details, aimed to simulate two different in-plane collapse mechanisms (with damage concentrated mostly on piers or also in spandrels), or to allow, in one case, also the activation of local out-of-plane mechanisms.