16 February 2017 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MAMahmoud Abdallah
Mahmoud Abdallah
KSKazuma Suzuki
Kazuma Suzuki
TTTakaharu Takeshita
Takaharu Takeshita
WKWataru Kitagawa
Wataru Kitagawa
Galvanic isolation based high-frequency transformers have become very attractive in bidirectional dc/ac converters. This paper presents a new pulse width modulation (PWM) switching technique for controlling a bidirectional isolated dc-ac-ac converter employing a high-frequency link transformer. The proposed PWM technique has the ability to control the input dc current and to inject a sinusoidal three-phase current to the grid at unity power factor. The primary-side is an H-bridge converter used to convert the dc voltage to a high-frequency square-wave single-phase voltage. The secondary side is a matrix converter used to convert the grid three-phase voltage to a high-frequency single-phase waveform. The dc-ac-ac converter utilizes a high-frequency link transformer for the galvanic isolation between the H-bridge and matrix converters as alternative for the bulky line-frequency transformers (50/60 Hz). The bidirectional power flow is controlled by the phase shift angle between the primary and secondary voltages of the high-frequency transformer. The mathematical model and the circuit operational modes are presented along with the voltage controllable limit. The feasibility of the proposed PWM switching technique and the accuracy of the mathematical model are demonstrated experimentally by using a 200 V/1 kW laboratory prototype system.

29 January 2014 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
MAMahmoud Abdallah
Mahmoud Abdallah
TTTakaharu Takeshita
Takaharu Takeshita
This paper presents the line loss minimum condition in isolated substations and same substation multiple loop distribution systems by using the unified power flow controller (UPFC). In each case, the mathematical model is presented and the line loss minimum conditions are obtained based on the line parameters of the distribution feeders. Since multiple loop distribution system is fed from same substation, the line loss minimization can be achieved by compensating the summation of the line reactance voltage drop. In an isolated substation loop distribution system, the line loss minimization can be achieved by compensating the summation of the line reactance voltage drop in addition to the voltage difference of the substations. Realization of both cases can be achieved if the loop current is eliminated from the loop system. The series compensation technique applied by the UPFC is used to eliminate the loop current from the loop distribution system and hence minimize the total line loss. The effectiveness of the proposed control schemes of the UPFC have been verified experimentally.

24 July 2017 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
MAMahmoud Abdallah
Mahmoud Abdallah
KSKazuma Suzuki
Kazuma Suzuki
TTTakaharu Takeshita
Takaharu Takeshita
WKWataru Kitagawa
Wataru Kitagawa
Soft-switching techniques have become very attractive in bidirectional grid-tie dc-ac converters utilizing high-frequency link transformers for galvanic isolation. This paper presents a new pulse-width modulation (PWM) switching technique for controlling a bidirectional isolated dc-ac-ac converter along with its soft-switching method. The proposed PWM technique has the ability to control the input dc current and to inject a sinusoidal three-phase current to the grid at unity power factor. In the first stage, an H-bridge converter is used to convert the dc voltage to a high-frequency square-wave single-phase voltage. In the second stage, a matrix converter is used to convert the high-frequency voltage waveform to conventional three-phase voltage synchronized with the grid. Therefore, a single-phase high-frequency transformer is used to link the H-bridge output voltage to the matrix converter input voltage. The proposed soft-switching technique is achieved by connecting shunt ceramic capacitors across all converter switches. The mathematical model and the circuit operation for soft-switching are presented along with the voltage controllable limits. The effectiveness of the proposed technique has been verified experimentally using a laboratory prototype.

10 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
Ahmed Ismail M. AliAhmed Ismail M. Ali
Ahmed Ismail M. Ali
MAMahmoud Abdallah
Mahmoud Abdallah
Osama MohammedOsama Mohammed
Osama Mohammed
This paper proposes a simple single-phase new pulse-width modulated seven-level inverter architecture for photovoltaic (PV) systems supporting home-grid with electric vehicle (EV) charging port. The proposed inverter includes a reduced number of power components and passive elements size, while showing less output-voltage total harmonic distortion (THD), and unity power factor operation. In addition, the proposed inverter requires simple control and switching strategies compared to recently published topologies. A comparative study was performed to compare the proposed inverter structure with the recent inverter topologies based on the number of components in the inverter circuit, number of components per output-voltage level, average number of active switches, THD, and operating efficiency as effective parameters for inverter performance evaluation. For design and validation purposes, numerical and analytical models for a grid-tied solar PV system driven by the proposed seven-level inverter were developed in MATLAB/Simulink environment. The inverter performance was evaluated considering grid-integration and stand-alone home with level-2 AC EV charger (3–6 kW). Compared with recently published topologies, the proposed inverter utilizes a reduced number of power components (7 switches) for seven-level terminal voltage synthesis. An experimental prototype for proposed inverter with the associated controller was built and tested for a stand-alone and grid-integrated system. Due to the lower number of ON-switches, the inverter operating efficiency was enhanced to 92.86% with load current THD of 3.43% that follows the IEEE standards for DER applications.

25 September 2022 in Sustainability
Verified
Journal Article
Open access
PDF file
Ahmed Ismail M. AliAhmed Ismail M. Ali
Ahmed Ismail M. Ali
ZAZuhair Muhammed Alaas
Zuhair Muhammed Alaas
MAMahmoud Abdallah
Mahmoud Abdallah
AAAbdulaziz Almalaq
Abdulaziz Almalaq
AFAnwar Farah
Anwar Farah
Mohamed A. MohamedMohamed A. Mohamed
Mohamed A. Mohamed
Central-type photovoltaic (PV) inverters are used in most large-scale standalone and grid-tied PV applications due to the inverter’s high efficiency and low-cost per kW generated. The perturbation and observation (P&O) and incremental conductance (IncCond) have become the most common techniques for maximum power point tracking (MPPT) strategies of PV/wind generation systems. Typically, the MPPT technique is applied in a two-stage operation; the first stage tracks the MPP and boosts the PV voltage to a certain level that complies with grid voltage, whereas the second stage represents the inversion stage that ties the PV system to the grid. Therefore, these common configurations increase the system size and cost as well as reduce its overall footprint. As a result, this paper applies two IncCond MPPT techniques on a proposed single-stage three-phase differential-flyback inverter (DFI). In addition, the three-phase DFI is analyzed for grid current negative-sequence harmonic compensation (NSHC). The proposed system efficiently provides a MPPT of the PV system and voltage boosting property of the DC-AC inverter in a single-stage operation. Moreover, the MPPT technique has been applied through the DFI using the conventional and modified IncCond tracking strategies. Furthermore, the system is validated for the grid-tied operation with the negative-sequence harmonic compensation strategy using computer-based simulation and is tested under uniform, step-change, as well as fast-changing irradiance profiles. The average efficiencies of the proposed system, considering the conventional and modified IncCond MPPT techniques, are 94.16% and 96.4% with tracking responses of 0.062 and 0.035 s and maximum overshoot of 46.15% and 15.38%, respectively.

7 August 2020 in IEEE Access
Verified
Journal Article
Open access
ASAhmed Shawky
Ahmed Shawky
TTTakaharu Takeshita
Takaharu Takeshita
MAMahmoud Abdallah
Mahmoud Abdallah
The simple circuit based on DC-DC converters is the main attractive feature of the differential inverter topologies. It has a single-stage and provides modularity and scalability. However, the Negative Sequence Harmonic Component (NSHC) generated at the output terminal may hinder its practical applications. This paper presents a single-stage three-phase isolated differential inverter based on three High-Frequency Link (HFL) transformer-based DC-DC SEPIC converters. The utilized SEPIC converters perform voltage step-up/ down capability with galvanic isolation, which is essential for Renewable Energy Sources (RES). It mitigates the Common-Mode Voltage (CMV) and Electro-Magnetic Interference (EMI). Moreover, this paper proposes a two-loop based d-q synchronous frame grid-current control to mitigate its NSHC. A Type-II compensator and simple NSHC detection circuit are proposed to enhance the inverter's stability and compensate phase-delay of the utilized SEPIC converters. NSHC detection is developed using three cascaded Low Path Filters (LPFs). A 1.6kW inverter prototype was set to validate the performance of the proposed inverter and its control. The control is implemented by the MWPE3 C6713A Expert III DSP board. The proposed topology has a maximum efficiency of 89.744 at 700W output power and 86.4% at full power. The proposed control decreases the NSHC from 40.6 % to 1.614%, which shows its accuracy and precision. Furthermore, THD is reduced from 35.61% to 4.087% and satisfy the recent grid codes (<5%). The simulation results using PSIM software, power loss distribution, and a comparison study of the proposed inverter with similar topologies are also presented.