Mohammed Al-Mandalawi

Mr. Mohammed Al-Mandalawi


Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 September 2022 in Polymers
Verified
Journal Article
Open access
PDF file
MAMohammed Al-Mandalawi
Mohammed Al-Mandalawi
MVMiklós Varga
Miklós Varga
LKLászló Kuzsela
László Kuzsela
Béla FiserBéla Fiser
Béla Fiser
LVLászló Vanyorek
László Vanyorek
BVBéla Viskolcz
Béla Viskolcz
In this work, three different polyurethane (PU) foams were prepared by mixing commonly used isocyanate and polyol with different isocyanate indices (1.0:0.8, 1.0:1.0, 1.0:1.1). Then, the prepared polyurethane foam samples were coated by dip-coating with a fixed ratio of nitrogen-doped, bamboo-shaped carbon nanotubes (N-BCNTs) to obtain pressure sensor systems. The effect of the isocyanate index on the initial resistance, pressure sensitivity, gauge factor (GF), and repeatability of the N-BCNT/PU pressure sensor systems was studied. The pore volume was crucial in finetuning the PU-foam-based sensors ability to detect large strain. Furthermore, large pore volume provides suitable spatial pores for elastic deformation. Sensors with large pore volume can detect pressure of less than 3 kPa, which could be related to their sensitivity in the high range. Moreover, by increasing the pore volume, the electrical percolation threshold can be achieved with a minimal addition of nanofillers. On the other hand, PU with a smaller pore volume is more suitable to detect pressure above 3 kPa. The developed sensors have been successfully applied in many applications, such as motion monitoring and vibration detection.

29 June 2021 in Polymers
Verified
Journal Article
Open access
PDF file
MAMohammed Al-Mandalawi
Mohammed Al-Mandalawi
MVMiklós Varga
Miklós Varga
LKLászló Kuzsela
László Kuzsela
ÁFÁdám Filep
Ádám Filep
Béla FiserBéla Fiser
Béla Fiser
LVLászló Vanyorek
László Vanyorek
In this study, a novel technology is reported to prepare a piezoresistive polyurethane-silicone rubber nanocomposite. Polyurethane (PU) foam was loaded with a nitrogen-doped bamboo-shaped carbon nanotube (N-BCNT) by using dip-coating, and then, impregnated with silicone rubber. PU was used as a supporting substrate for N-BCNT, while silicone rubber was applied to fill the pores of the foam to improve recoverability, compressive strength, and durability. The composite displays good electrical conductivity, short response time, and excellent repeatability. The resistance was reduced when the amount of N-BCNT (0.43 wt %) was increased due to the expanded conductive path for electron transport. The piezoresistive composite has been successfully tested in many applications, such as human monitoring and finger touch detection.

24 April 2026 in RSC Advances
Verified
Journal Article
Open access
SASaba Ahmed Abdulkareem
Saba Ahmed Abdulkareem
Khalid Turki RashidKhalid Turki Rashid
Khalid Turki Rashid
AAAdnan A. AbdulRazak
Adnan A. AbdulRazak
Mohammed Ahmed ShehabMohammed Ahmed Shehab
Mohammed Ahmed Shehab
MAMohammed Al-Mandalawi
Mohammed Al-Mandalawi
HMHaidar Hasan Mohammed
Haidar Hasan Mohammed
Green functional resource for tailoring membrane features and performance in wastewater treatment.

11 October 2026 in Advanced Composites and Hybrid Materials
Verified
Journal Article
Open access
PDF file
MAMohammed Al-Mandalawi
Mohammed Al-Mandalawi
Ali J AddieAli J Addie
Ali J Addie
NTNabil Kadhim Taieh
Nabil Kadhim Taieh
LVLászló Vanyorek
László Vanyorek
YLYing Li
Ying Li
Bio-inspired flexible pressure sensors have emerged as a major class of soft sensing systems for wearable electronics, electronic skin, human–machine interfaces, and soft robotics because biological structures provide effective design principles for regulating deformation, contact evolution, and interfacial adaptation. However, the field remains difficult to compare critically because reported performance is often discussed through isolated sensitivity values, while the structural origins of signal generation, the pressure-regime dependence of response, and the reliability limits of the underlying architectures are not examined in a unified manner. This review addresses that gap through a morphology-centered perspective, in which bio-inspired pressure sensors are analyzed according to the engineered structural motifs that govern their function. Surface-relief and contact-engineered architectures, porous and three-dimensional frameworks, interfacial, interlocking, and adhesive systems, and hierarchical or discontinuity-driven designs are examined in relation to their coupling with piezoresistive, capacitive, iontronic, triboelectric, piezoelectric, and hybrid transduction pathways. Across these classes, sensitivity, operating range, dynamic response, hysteresis, drift, durability, and failure behavior are traced to the pressure-responsive structural features that define each architecture. This analysis further shows that features designed to amplify signal often also set the boundaries for reversibility and long-term stability. Finally, current challenges in benchmarking and validation are discussed, with emphasis on the need for morphology-traceable reporting, realistic reliability assessment, and structure-guided design rules for future bio-inspired flexible pressure sensors.