Tarek M. Elshazly

Dr. Tarek M. Elshazly

Oral Technology Department, University of Bonn, Bonn, North Rhine-Westphalia, Germany
orcid
B.D.S., M.D.Sc., Dr.med.dent., M.D./Ph.D. - an Orthodontist ...

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
IAIslam Atta
Islam Atta
CBChristoph P Bourauel
Christoph P Bourauel
YAYasmine Alkabani
Yasmine Alkabani
NMNesreen Mohamed
Nesreen Mohamed
Hoon KimHoon Kim
Hoon Kim
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
To conduct a physiochemical and mechanical material analysis on 3D printed shape-memory aligners in comparison to thermoformed aligners. Four materials were examined, including three thermoformed materials: CA Pro (CP), Zendura A (ZA), Zendura FLX (ZF), and one 3D printed material: Tera Harz (TC-85). Rectangular strips measuring 50 × 10 × 0.5 mm were produced from each material. Five tests were conducted, including differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), shape recovery tests, three-points bending (3 PB), and Vickers surface microhardness (VH). DSC recorded glass transition temperatures (Tg) at 79.9 °C for CP, 92.2 °C for ZA, 107.1 °C for ZF, and 42.3 °C for TC-85. In DMA analysis at 20-45 °C, a prominent decrease in storage modulus was observed, exclusively for TC-85, as the temperature increased. Notably, within the temperature range of 30-45 °C, TC-85 exhibited substantial shape recovery after 10 min, reaching up to 86.1 %, while thermoformed materials showed minimal recovery (1.5-2.9 %). In 3 PB test (at 30, 37, 45 °C), ZA demonstrated the highest force at 2 mm bending, while TC-85 exhibited the lowest. Regarding VH at room temperature, there was a significant decrease for both ZA and ZF after thermoforming. ZA had the highest hardness, followed by ZF and TC-85, with CP showing the lowest values. TC-85 demonstrates exceptional shape memory at oral temperature, improving adaptation, reducing force decay, and enabling, together with its higher flexibility, extensive tooth movement per step. Additionally, it maintains microhardness similar to thermoformed sheets, ensuring the durability and effectiveness of dental aligners. The 3D printed aligner material with shape memory characteristics (4D aligner) has revolutionized the orthodontic aligner field. It showed mechanical properties more suitable for orthodontic treatment than thermoforming materials. Additionally, it offers enhanced control over aligner design and thickness, while optimizing the overall workflow. It also minimizes material wastage, and reduces production expenses.

30 August 2022 in Journal of Dentistry
Verified
Journal Article
Open access
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
LKLudger Keilig
Ludger Keilig
DSDamiano Salvatori
Damiano Salvatori
PCPhilippe Chavanne
Philippe Chavanne
Mostafa AldesokiMostafa Aldesoki
Mostafa Aldesoki
CBChristoph P Bourauel
Christoph P Bourauel
To investigate how the stress distribution and forces transmitted from orthodontic aligners to the tooth surface are affected by the geometry and extension of the trimming line. Thirty-six aligners were thermoformed from Zendura FLX sheets (0.75 mm thick) and divided into four groups based on the design of the trimming line: Scalloped, Scalloped extended, Straight and Straight extended. Fuji pressure-sensitive films were used for pressure measurement. The pressurized films were scanned and evaluated. Pressures and forces were measured over the entire facial surface of an upper right central incisor (Tooth 11) and at 7 different locations [cervical, middle, incisal, mesio-incisal, mesio-cervical, disto-incisal, and disto-cervical]. In addition, the thickness of the aligners at these 7 sites was measured with a digital caliper. The active force ranged from (2.2 to 6.9) N, and the average pressure was (1.6-2.7) MPa. The highest values were recorded for the (straight extended) design, while the lowest values were recorded for the scalloped design. The forces and stresses were not uniformly distributed over the surface. When the values in each area were compared separately, significant differences were found between the different designs in the cervical area, with the scalloped design transmitting the lowest cervical forces. Aligner thickness was drastically reduced (60-75% thinning) over the entire tooth surface after thermoforming. The straight extended design of aligner's trimming line exhibited more uniform force transfer and stress distribution across the surface than the other designs. The trimming line design could have a significant impact on the clinical outcome of orthodontic aligner treatment.

10 March 2021 in Dentistry Journal
Verified
Journal Article
Open access
PDF file
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
LKLudger Keilig
Ludger Keilig
YAYasmine Alkabani
Yasmine Alkabani
AGAhmed Ghoneima
Ahmed Ghoneima
MAMoosa Abuzayeda
Moosa Abuzayeda
CBChristoph P Bourauel
Christoph P Bourauel
As an innovative approach to overcome the rate-limiting staging of conventional aligners, using shape memory polymers (SMPs) as aligners’ materials was investigated in this in vitro study. The ability of SMPs to shape recover and consequently move tooth, upon appropriate stimuli, was evaluated on a typodont model before clinical application. The study design was to achieve 1.9 mm correction movement of an upper central incisor by one aligner after multiple steps/activation. A custom-made aligned typodont model with a movable upper central incisor was scanned. Using an orthodontic software and a 3D printer, resin-models were generated. Seven aligners of ClearX sheets (SMPs) were fabricated by thermoforming on the resin aligned model. Each aligner was tested for repositioning of the central incisor in the typodont model. The model was scanned after each step and the corrective movement was measured through the superimposition of scans. Results showed that the total correction efficiency of the SMPs’ aligner was ≈93% (1.76 mm). The corrective movement was 0.94 ± 0.04 mm after the reforming step, 0.66 ± 0.07 mm after the first activation step, and 0.15 ± 0.10 mm after the second activation step. It was concluded that aligners made of SMPs could have a promising future-use in orthodontic aesthetic treatment.

28 January 2022 in Frontiers in Materials
Verified
Journal Article
Open access
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
LKLudger Keilig
Ludger Keilig
YAYasmine Alkabani
Yasmine Alkabani
AGAhmed Ghoneima
Ahmed Ghoneima
MAMoosa Abuzayda
Moosa Abuzayda
CBChristoph P. Bourauel
Christoph P. Bourauel
Objectives: To investigate and quantify forces generated by three-dimensional-printed aligners made of shape memory polymers (four-dimensional [4D] aligner).Methods: Clear X v1.1 material was used in this study. On a custom-made typodont model, correction of maxillary central incisor (tooth 21) malposition by 4D aligners with thicknesses of 0.8 and 1.0 mm was measured by superimposition of subsequent scans. Maximum deflection forces generated by foil sheet specimens were measured at different temperatures in three-point bending (3-PB) tests. In a biomechanical system (orthodontic measurement and simulation system [OMSS]), forces generated on movements of tooth 21 by the 4D aligners were measured at different temperatures.Results: 4D aligners succeeded to achieve a significant tooth movement (2.5 ± 0.5 mm) on the typodont, with insignificant difference between different thicknesses. In the 3-PB test, the maximum deflection forces measured at 20, 30, 37, 45, and 55°C, were 3.8 ± 1.1, 2.5 ± 0.9, 1.7 ± 0.6, 1.0 ± 0.4, and 0.5 ± 0.4 N, respectively. Forces delivered on palatal displacement of tooth 21 at 37, 45, and 55°C by 0.8-mm aligners were 0.3 ± 0.1, 0.2 ± 0.1, and 0.7 ± 0.2 N, respectively, whereas those by 1.0-mm aligners were 0.3 ± 0.1, 0.3 ± 0.1, and 0.6 ± 0.2 N, respectively. A good concordance with movement on the typodont model was shown in OMSS.Conclusion: An initial study of 4D-printed aligner shows its ability to move a tooth by biocompatible orthodontic forces, after a suitable thermal stimulus within the oral temperature range.

22 August 2022 in Clinical Oral Investigations
Verified
Journal Article
Closed access
PDF file
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
CBChristoph Bourauel
Christoph Bourauel
MAMostafa Aldesoki
Mostafa Aldesoki
AGAhmed Ghoneima
Ahmed Ghoneima
MAMoosa Abuzayda
Moosa Abuzayda
LKLudger Keilig
Ludger Keilig

19 April 2024 in Clinical Oral Investigations
Verified
Journal Article
Open access
PDF file
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
CBChristoph Bourauel
Christoph Bourauel
AIAhmed Ismail
Ahmed Ismail
OGOmar Ghoraba
Omar Ghoraba
MAMostafa Aldesoki
Mostafa Aldesoki
YAYasmine Alkabani
Yasmine Alkabani
Objectives: To investigate the effects of material type and thickness on force generation and distribution by aligners. Materials and methods: Sixty aligners were divided into six groups (n = 10): one group with a thickness of 0.89 mm using Zendura Viva (Multi-layer), four groups with a thickness of 0.75 mm using Zendura FLX (Multi-layer), CA Pro (Multi-layer), Zendura (Single-layer), and Duran (Single-layer) sheets, and one group with a thickness of 0.50 mm using Duran sheets. Force measurements were conducted using Fuji® pressure-sensitive films. Results: The lowest force values, both active and passive, were recorded for the multi-layered sheets: CA Pro (83.1 N, 50.5 N), Zendura FLX (88.9 N, 60.7 N), and Zendura Viva (92.5 N, 68.5 N). Conversely, the highest values were recorded for the single-layered sheets: Duran (131.9 N, 71.8 N) and Zendura (149.7 N, 89.8 N). The highest force was recorded at the middle third of the aligner, followed by the incisal third, and then the cervical third. The net force between the incisal and cervical thirds (FI-FC) showed insignificant difference across different materials. However, when comparing the incisal and middle thirds, the net force (FI-FM) was higher with single-layered materials. Both overall force and net force (FI-FM) were significantly higher with 0.75 mm compared to those with a thickness of 0.50 mm. Conclusions: Multi-layered aligner materials exert lower forces compared to their single-layered counterparts. Additionally, increased thickness in aligners results in enhanced retention and greater force generation. For effective bodily tooth movement, thicker and single-layered rigid materials are preferred. Clinical relevance: This research provides valuable insights into the biomechanics of orthodontic aligners, which could have significant clinical implications for orthodontists. Orthodontists might use this information to more effectively tailor aligner treatments, considering the specific tooth movement required for each individual patient. In light of these findings, an exchangeable protocol for aligner treatment is suggested, which however needs to be proven clinically. This protocol proposes alternating between multi-layered and single-layered materials within the same treatment phase. This strategy is suggested to optimize treatment outcomes, particularly when planning for a bodily tooth movement.