Hoon Kim

Dr. Hoon Kim

Seoul National Univeristy
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 April 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
SLSe Yeon Lee
Se Yeon Lee
Hoon KimHoon Kim
Hoon Kim
HKHyun-Joong Kim
Hyun-Joong Kim
CCChooryung J. Chung
Chooryung J. Chung
YCYoon Jeong Choi
Yoon Jeong Choi
JCJung Yul Cha
Jung Yul Cha
To overcome the limitations of the conventional vacuum thermoforming manufacturing method, direct 3D printing of clear aligners has been developed. The present study investigated the thermo-mechanical and viscoelastic properties of a photocurable resin TC-85, which is a new material for the direct 3D printed clear aligners, comparing to a conventional thermoplastic material polyethylene terephthalate glycol. Dynamic mechanical analysis was performed to analyse the mechanical behaviours of the two materials at 37 °C and 80 °C, respectively. Furthermore, the shape memory property of the two materials was evaluated using a U-shape bending test, and the shape recovery ratio for 60 min at 37 °C was calculated. The results indicate that TC-85 can constantly apply a light force to the teeth when used for the 3D printed clear aligners, owing to its flexibility and viscoelastic properties. In addition, it is expected that the force decay induced by repeated insertion of the clear aligners will be reduced and a constant orthodontic force will be maintained. Furthermore, its geometric stability at high temperatures and the shape memory properties provide advantages for the clinical application.

25 December 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Open access
IAIslam Atta
Islam Atta
CBChristoph P Bourauel
Christoph P Bourauel
YAYasmine Alkabani
Yasmine Alkabani
NMNesreen Mohamed
Nesreen Mohamed
Hoon KimHoon Kim
Hoon Kim
Tarek M. ElshazlyTarek M. Elshazly
Tarek M. Elshazly
To conduct a physiochemical and mechanical material analysis on 3D printed shape-memory aligners in comparison to thermoformed aligners. Four materials were examined, including three thermoformed materials: CA Pro (CP), Zendura A (ZA), Zendura FLX (ZF), and one 3D printed material: Tera Harz (TC-85). Rectangular strips measuring 50 × 10 × 0.5 mm were produced from each material. Five tests were conducted, including differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), shape recovery tests, three-points bending (3 PB), and Vickers surface microhardness (VH). DSC recorded glass transition temperatures (Tg) at 79.9 °C for CP, 92.2 °C for ZA, 107.1 °C for ZF, and 42.3 °C for TC-85. In DMA analysis at 20-45 °C, a prominent decrease in storage modulus was observed, exclusively for TC-85, as the temperature increased. Notably, within the temperature range of 30-45 °C, TC-85 exhibited substantial shape recovery after 10 min, reaching up to 86.1 %, while thermoformed materials showed minimal recovery (1.5-2.9 %). In 3 PB test (at 30, 37, 45 °C), ZA demonstrated the highest force at 2 mm bending, while TC-85 exhibited the lowest. Regarding VH at room temperature, there was a significant decrease for both ZA and ZF after thermoforming. ZA had the highest hardness, followed by ZF and TC-85, with CP showing the lowest values. TC-85 demonstrates exceptional shape memory at oral temperature, improving adaptation, reducing force decay, and enabling, together with its higher flexibility, extensive tooth movement per step. Additionally, it maintains microhardness similar to thermoformed sheets, ensuring the durability and effectiveness of dental aligners. The 3D printed aligner material with shape memory characteristics (4D aligner) has revolutionized the orthodontic aligner field. It showed mechanical properties more suitable for orthodontic treatment than thermoforming materials. Additionally, it offers enhanced control over aligner design and thickness, while optimizing the overall workflow. It also minimizes material wastage, and reduces production expenses.

30 April 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
Hoon KimHoon Kim
Hoon Kim
KRKwang-Hyun Ryu
Kwang-Hyun Ryu
Dooyoung BaekDooyoung Baek
Dooyoung Baek
TKTanveer Ahmed Khan
Tanveer Ahmed Khan
HKHyun-Joong Kim
Hyun-Joong Kim
JKJaseung Koo
Jaseung Koo

22 April 2021 in ACS Applied Polymer Materials
Verified
Journal Article
Closed access
MYMo-Beom Yi
Mo-Beom Yi
TLTae-Hyung Lee
Tae-Hyung Lee
GHGi-Yeon Han
Gi-Yeon Han
Hoon KimHoon Kim
Hoon Kim
HKHyun-Joong Kim
Hyun-Joong Kim
DJDong-Un Jin
Dong-Un Jin

22 September 2022 in Children
Verified
Journal Article
Open access
PDF file
NKNayoung Kim
Nayoung Kim
Hoon KimHoon Kim
Hoon Kim
IKIk-Hwan Kim
Ik-Hwan Kim
JLJiho Lee
Jiho Lee
KLKo Eun Lee
Ko Eun Lee
Yooseok ShinYooseok Shin
Yooseok Shin
This study evaluated the fracture resistance, biaxial flexural strength (BFS), and dynamic mechanical analysis (DMA) of three-dimensional (3D) printing resins for the esthetic restoration of primary molars. Two 3D printing resins, Graphy (GP) and NextDent (NXT), and a prefabricated zirconia crown, NuSmile (NS), were tested. GP and NXT samples were 3D printed using the workflow recommended by each manufacturer. Data were collected and statistically analyzed. As a result of the fracture resistance test of 0.7-mm-thick 3D printed resin crowns with a thickness similar to that of the NS crown, there was no statistically significant difference among GP (1491.6 ± 394.6 N), NXT (1634.4 ± 289.3 N), and NS (1622.8 ± 323.9 N). The BFS of GP was higher for all thicknesses than that of NXT. Both resins showed high survival probabilities (more than 90%) when subjected to 50 and 150 MPa. Through DMA, the glass transition temperatures of GP and NXT were above 120 °C and the rheological behavior of GP and NXT according to temperature and frequency were analyzed. In conclusion, GP and NXT showed optimum strength to withstand bite forces in children, and 3D printed resin crowns could be an acceptable option for fixed prostheses of primary teeth.

12 August 2021 in Polymers
Verified
Journal Article
Open access
PDF file
KKKyung-Min Kim
Kyung-Min Kim
Hoon KimHoon Kim
Hoon Kim
Kim Hyun-JoongKim Hyun-Joong
Kim Hyun-Joong
The objectives of this study are to improve the thermal and mechanical properties of epoxy/fumed silica composite with different surface treatments of fumed silica. The addition of silica nanoparticles improved the thermal stability of the composite and slowed down the pyrolysis process. The crosslinking density and Tg of the epoxy/fumed silica composites increased because of the interfacial interaction between the PDMS-treated fumed silica particles and the epoxy matrix. The flexural strength of the epoxy nanocomposite was very high even at a low silica content because of the strong interactions between the PDMS-treated fillers and the epoxy matrix. These strong interfacial interactions originate from the attractive forces between the polymer and the filler. Therefore, the polymer nanocomposite containing the PDMS-treated fumed silica is shown to be sufficiently commercially promising.