Renato Leone

Prof. Renato Leone

University of Naples Federico II, Naples, Campania, Italy
orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2018 in Dental Materials
Verified
Journal Article
Closed access
ECE. Camposilvan
E. Camposilvan
RLRenato Leone
Renato Leone
Laurent GremillardLaurent Gremillard
Laurent Gremillard
Roberto SorrentinoRoberto Sorrentino
Roberto Sorrentino
FZF. Zarone
F. Zarone
Jérôme ChevalierJérôme Chevalier
Jérôme Chevalier

18 August 2016 in International Journal of Dentistry
Verified
Journal Article
Open access
PDF file
Fernando ZaroneFernando Zarone
Fernando Zarone
Marco FerrariMarco Ferrari
Marco Ferrari
FMFrancesco Guido Mangano
Francesco Guido Mangano
RLRenato Leone
Renato Leone
RSRoberto Sorrentino
Roberto Sorrentino
The present paper was aimed at reporting the state of the art about lithium disilicate ceramics. The physical, mechanical, and optical properties of this material were reviewed as well as the manufacturing processes, the results of in vitro and in vivo investigations related to survival and success rates over time, and hints for the clinical indications in the light of the latest literature data. Due to excellent optical properties, high mechanical resistance, restorative versatility, and different manufacturing techniques, lithium disilicate can be considered to date one of the most promising dental materials in Digital Dentistry.

1 June 2021 in Journal of Dentistry
Verified
Journal Article
Open access
Fernando ZaroneFernando Zarone
Fernando Zarone
Gennaro RuggieroGennaro Ruggiero
Gennaro Ruggiero
RLRenato Leone
Renato Leone
Lorenzo BreschiLorenzo Breschi
Lorenzo Breschi
Stefania LeuciStefania Leuci
Stefania Leuci
Roberto SorrentinoRoberto Sorrentino
Roberto Sorrentino
This paper aimed to provide a literature review of the mechanical and biological properties of zirconia-reinforced lithium silicate glass-ceramics (ZLS) in Computer-aided design / Computer-aided manufacturing (CAD/CAM) systems. An extensive search of the literature for papers related to ZLS was made on the databases of PubMed/Medline, Scopus, Embase, Google Scholar, Dynamed, and Open Grey. The papers were selected by 3 independent calibrated reviewers. The search strategy produced 937 records. After the removal of duplicates and the exclusion of papers that did not meet the inclusion criteria, 71 papers were included. After reviewing the included records, it was found that two types of ZLS (Vita Suprinity PC; Vita Zahnfabrik and Celtra Duo; Dentsply Sirona) are nowadays available on the market for CAD/CAM systems, similar in their chemical composition, microstructure, and biological-mechanical properties. ZLS is reported to be a biocompatible material, whose fracture resistance can withstand physiological chewing loads. The firing process influences the improvements of strength and fatigue failure load, with a volumetric shrinkage. To date, ZLS can be considered a viable alternative to other glass-ceramics for fixed single restorations. . As to biocompatibility and mechanical properties of ZLS, data are still scarce, often controversial and limited to short-term observational periods. These promising ceramics require further in vitro/in vivo studies to accurately define mechanical and biological properties, mainly in the long-term performance of restorations produced with such materials.

8 April 2023 in Biomedicines
Verified
Journal Article
Open access
PDF file
BDBianca D’Orto
Bianca D’Orto
CCCarlo Chiavenna
Carlo Chiavenna
RLRenato Leone
Renato Leone
MLMartina Longoni
Martina Longoni
MNMatteo Nagni
Matteo Nagni
Paolo CapparèPaolo Capparè
Paolo Capparè
The aim of this study was to assess and compare the marginal bone loss between two different categories of implants (Winsix, Biosafin, Ancona, Italy) having the same diameter and belonging to the Torque Type® (TT®) line, in the internal hexagon version (TTi, Group A) and in the external hexagon configuration (TTx, Group B). Patients with one or more straight implants (insertion parallel to the occlusal plane) in the molar and premolar regions in association with tooth extraction at least 4 months prior to implant insertion, who have a fixture diameter of 3.8 mm, who followed up for at least 6 years, and whose radiographic records were available were enrolled in this study. Depending on implant connections (externally or internally), the sample was divided into groups A and B. For externally connected implants (66), the marginal resorption was 1.1 ± 0.17 mm. The subgroup of single and bridge implants showed no statistically significant differences with a marginal bone resorption of 1.07 ± 0.15 mm and 1.1 ± 0.17 mm, respectively. Internally connected implants (69) showed an overall marginal resorption of 0.91 ± 0.17 mm, while the subgroup of single and bridge implants showed resorption of 0.90 ± 0.19 mm and 0.90 ± 0.17 mm, respectively, with no statistically significant differences. According to the obtained results, internally connected implants showed less marginal bone resorption than externally connected implants.

27 July 2022 in Prosthesis
Verified
Journal Article
Open access
PDF file
Roberto SorrentinoRoberto Sorrentino
Roberto Sorrentino
Gennaro RuggieroGennaro Ruggiero
Gennaro Ruggiero
Eralda ToskaEralda Toska
Eralda Toska
RLRenato Leone
Renato Leone
Fernando ZaroneFernando Zarone
Fernando Zarone
Background: Different technologies and materials can be used for implant-supported restorations in posterior areas. Our study aimed to evaluate the clinical performance of CAD/CAM implant-supported monolithic zirconia single crowns (ZrSCs) cemented onto titanium abutments with a dual-curing resin cement after 6 years of use. Methods: Fifty patients in need of one single crown in posterior regions were enrolled. The patients were recalled for a follow-up after 6 months and then yearly for a total observation period of 6 years. The biological and technical complications were examined using criteria set by the United States Public Health Service (USPHS), whereas visual analogue scales (VASs) were used to evaluate the patients’ aesthetic and functional satisfaction. Results: No patient was lost at follow-up; both the survival and success rates were 100%. No fractures, decementation, peri-implantitis, or soft tissue inflammation were recorded. Forty-six restorations were rated Alpha in each evaluated parameter of the USPHS’s criteria. According to the patients’ VASs assessments, the overall function of the ZrSCs was 8.4 (±2.1), whereas the overall aesthetic was 8.7 (±0.7). Conclusions: Monolithic zirconia single crowns cemented with dual-curing resin cements onto titanium abutments can be considered an effective clinical option in posterior regions after 6 years of function.

23 September 2022 in Prosthesis
Verified
Journal Article
Open access
PDF file
FFFederico Franchini
Federico Franchini
MFMassimo Fuzzi
Massimo Fuzzi
RLRenato Leone
Renato Leone
Roberto SorrentinoRoberto Sorrentino
Roberto Sorrentino
Computer-guided software and kits have significantly improved the clinical applications of implant surgery. Nonetheless, some technical problems are still in evidence during clinical procedures because of cumbersome surgical tools that can limit access to implant sites, mainly in posterior areas of the mouth in the presence of bulky anatomical structures and in patients with reduced mouth-opening capacity. The present paper aimed to present a novel approach to guided implant surgery, describing the technical characteristics of an innovative guided surgical kit made up of modified sleeves and modular surgical drills. The proposed guided surgical kit is based on a novel patented system of sleeves and modular burs, with an increased length of the metal sleeves and a reduced height of the drills. The innovative design of the proposed system would allow the clinician to position guided fixtures in all clinical situations; the reduced encumbrance would be particularly helpful to gain access to the posterior areas of both maxilla and mandible, which have limited inter-arch space, with an easy and user-friendly approach. The modular system could overcome anatomical limitations, such as reduced mouth-opening capacity, and permit clinicians to maintain the stability and integrity of the surgical templates, even in cases where there is very limited intermaxillary space.