Although industrial shoulder exoskeletons have undergone rapid advancement, their acceptance by industrial workers is limited owing to the misalignment and interference between the exoskeletal frame and the wearer’s body and bulkiness of the frames. Several joint mechanisms have been developed to offset misalignments; however, none of the existing systems can simultaneously alleviate the interference and bulkiness problems. Furthermore, the reduction in the misalignments in terms of forces generated at the human–robot interface has not been experimentally verified. Therefore, in this study, design optimization was performed to address the various factors that limit the use of the existing industrial shoulder exoskeletons. Upper body motions were captured and converted into a target trajectory for the exoskeleton to follow. The optimal prismatic–revolute–revolute joint configuration was derived and used to manufacture a skeletal mock-up, which was used to perform experiments. The misalignments of the optimized configuration in the considered motions were 67% lower than those for the conventional joint configuration. Furthermore, the interaction forces were negligible (1.35 N), with a maximum reduction of 61.8% compared to those of conventional configurations.
Although exosuits have several advantages compared to exoskeleton type of wearable robots, they have limitations, such as bulkiness and low control performance. This study addresses the design and evaluation of a compact, lightweight, and highly responsive actuator to be used for exosuits, based on the Quasi-Direct Drive (QDD) actuation. The design requirements of the actuator were set based on the actuation system used in the state-of-the-art exosuit from Harvard University (HE) so that it could be an improvement compared to HE. Several design concepts were comparatively evaluated to select the optimal design, and a design for the pulley embedded QDD (PEQDD) actuator was selected. The PEQDD was fabricated using mechanical components selected based on the design constraints or designed through mechanical analysis. Using a dynamometer, the efficiency map of the PEQDD was drawn. The control bandwidth comparison test with the motor originally used for HE showed improved bandwidth from 6.25 Hz to 20 Hz. Preliminary testing was done in walking and running conditions using an exosuit utilizing PEQDD. The test results showed that the actuator performance met all the design requirements.
The back support exoskeletons have garnered significant attention to alleviate musculoskeletal injuries, prevalent in industrial settings. In this paper, we propose AeBS, a quasi-passive back-support exoskeleton developed to provide variable assistive torque across the entire range of hip joint motion, for tasks with frequent load changes. AeBS can adjust the assistive torque levels while minimizing energy for the torque variation without constraining the range of motion of the hip joint. To match the requisite assistance levels for back support, a compact variable gravity compensation module with reinforced elastic elements is applied to AeBS. Additionally, we devised a bio-inspired hip joint mechanism that mimics the configuration of the human hip axis to ensure the free body motion of the wearer, significantly affecting assistive torque transmission and wearing comfort. Benchtop testing showed that AeBS has a variable assistive torque range of 5.81 Nm (ranging from 1.23 to 7.04 Nm) across a targeted hip flexion range of 135°. Furthermore, a questionnaire survey revealed that the bio-inspired hip joint mechanism effectively facilitates the transmission of the intended assistive torque while enhancing wearer comfort.
In this study, we propose a bioinspired design methodology for a multifunctional lever based on the morphological principle of the lever mechanism in the Salvia pratensis flower. The proposed divide-and-conquer contour design methodology does not treat a lever contour as a single curve that satisfies multiple functions. Rather, the lever contour combines partial contours to achieve its assigned subfunction. This approach can simplify the complex multifunctional problem in lever design. We include a case study of a lever utilized in a compact variable gravity compensator (CVGC) to explain the methodology in more detail. In the case study, four partial contours were designed to satisfy three types of functional requirements. The final design for the lever contour was manufactured and verified with visual measurement experiments. The experimental result shows that each partial contour successfully achieved its subfunctions.