The use of wearable robots to provide walking assistance has rapidly grown over the past decade, with notable advances made in robot design and control methods toward reducing physical effort while performing an activity. The reduction in walking effort has mainly been achieved by assisting forward progression in the sagittal plane. Human gait, however, is a complex movement that combines motions in three planes, not only the sagittal but also the transverse and frontal planes. In the frontal plane, the hip joint plays a key role in gait, including balance. However, wearable robots targeting this motion have rarely been investigated. In this study, we developed a hip abduction assistance wearable robot by formulating the hypothesis that assistance that mimics the biological hip abduction moment or power could reduce the metabolic cost of walking and affect the dynamic balance. We found that hip abduction assistance with a biological moment second peak mimic profile reduced the metabolic cost of walking by 11.6% compared with the normal walking condition. The assistance also influenced balance-related parameters, including the margin of stability. Hip abduction assistance influenced the center-of-mass movement in the mediolateral direction. When the robot assistance was applied as the center of mass moved toward the opposite leg, the assistance replaced some of the efforts that would have otherwise been provided by the human. This indicates that hip abduction assistance can reduce physical effort during human walking while influencing balance.
7 July 2021 in IEEE/ASME Transactions on Mechatronics
This article proposes a new version of a variable gravity compensation mechanism (CVGC-II) for mobile manipulation robots, such as mobile manipulators and exoskeletons. CVGC-II, which incorporated an energy-free variable mechanism in a smaller design space, exhibited improved performance with a wider range of variable torque values. These enhancements were achieved by adopting an optimal curved lever and hybrid spring system. First, the mechanism concept and specifications of the CVGC mechanism are described. Next, the contribution of the curved lever and hybrid spring system to the performance enhancement of CVGC-II is explained. Subsequently, the design methodologies for the main mechanical elements, including the lever, hybrid spring, and cam, are introduced. In the lever design, Hermite spline and B-spline curve model-based optimization is performed to generate the optimal curved shape of the lever. The hybrid spring system, consisting of compression coil springs and layered leaf springs, helps achieve a wider variable range by maximizing the storable energy in a limited design space. The experimental results showed that CVGC-II exhibited a 6.8 times wider variable range and energy-free variable mechanism under 1.5 and 1.3 times smaller size and weight, respectively.
Although industrial shoulder exoskeletons have undergone rapid advancement, their acceptance by industrial workers is limited owing to the misalignment and interference between the exoskeletal frame and the wearer’s body and bulkiness of the frames. Several joint mechanisms have been developed to offset misalignments; however, none of the existing systems can simultaneously alleviate the interference and bulkiness problems. Furthermore, the reduction in the misalignments in terms of forces generated at the human–robot interface has not been experimentally verified. Therefore, in this study, design optimization was performed to address the various factors that limit the use of the existing industrial shoulder exoskeletons. Upper body motions were captured and converted into a target trajectory for the exoskeleton to follow. The optimal prismatic–revolute–revolute joint configuration was derived and used to manufacture a skeletal mock-up, which was used to perform experiments. The misalignments of the optimized configuration in the considered motions were 67% lower than those for the conventional joint configuration. Furthermore, the interaction forces were negligible (1.35 N), with a maximum reduction of 61.8% compared to those of conventional configurations.
Although exosuits have several advantages compared to exoskeleton type of wearable robots, they have limitations, such as bulkiness and low control performance. This study addresses the design and evaluation of a compact, lightweight, and highly responsive actuator to be used for exosuits, based on the Quasi-Direct Drive (QDD) actuation. The design requirements of the actuator were set based on the actuation system used in the state-of-the-art exosuit from Harvard University (HE) so that it could be an improvement compared to HE. Several design concepts were comparatively evaluated to select the optimal design, and a design for the pulley embedded QDD (PEQDD) actuator was selected. The PEQDD was fabricated using mechanical components selected based on the design constraints or designed through mechanical analysis. Using a dynamometer, the efficiency map of the PEQDD was drawn. The control bandwidth comparison test with the motor originally used for HE showed improved bandwidth from 6.25 Hz to 20 Hz. Preliminary testing was done in walking and running conditions using an exosuit utilizing PEQDD. The test results showed that the actuator performance met all the design requirements.