Background: Human beings can enhance their distance running performance with the help of assistive devices. Although several such devices are available, they are heavy and bulky, which limits their use in everyday activities. In this study, we developed a lightweight running assistive device with a low-profile design. The device applies a flexion moment to the hip according to the hip extension within a specific range of motion to assist running. Methods: A passive exosuit was fabricated using textile materials and elastic bands. The deformation of the suit was measured and compensated for in the design. The fabricated suit was tested on eight participants (age: 24.4 ± 3.8 y; height: 1.72 ± 0.05 m; weight: 74.5 ± 6.1 kg) who were instructed to run on a treadmill at a speed of 2.5 m/s. Through indirect calorimetry, the metabolic rate was measured for the no-suit condition and three band conditions. Variations in the spatiotemporal parameters were measured using a motion capture system and force-sensing resistors (FSRs). Results: When using the fabricated device, seven out of the eight participants exhibited a reduced metabolic rate in at least one of the three band conditions. An average reduction of − 4.7 ± 1.4% (mean ± standard error of the mean (s.e.m.), two-sided paired t-test, p = 0.017) was achieved when using the best-fitting bands compared to the average of the two no-suit conditions. No statistically significant changes were observed in the spatiotemporal parameters, except for the stance duration in the medium assistance force condition. Conclusions: The proposed passive exosuit, which has a low weight of 609 g and small extrusion of 2.5 cm from the body in standing posture, can reduce the metabolic rate during running. The proposed device can potentially be used every day owing to its low-profile design and low weight, thereby overcoming the limitations of existing portable devices targeting the hip joints.
Although exosuits have several advantages compared to exoskeleton type of wearable robots, they have limitations, such as bulkiness and low control performance. This study addresses the design and evaluation of a compact, lightweight, and highly responsive actuator to be used for exosuits, based on the Quasi-Direct Drive (QDD) actuation. The design requirements of the actuator were set based on the actuation system used in the state-of-the-art exosuit from Harvard University (HE) so that it could be an improvement compared to HE. Several design concepts were comparatively evaluated to select the optimal design, and a design for the pulley embedded QDD (PEQDD) actuator was selected. The PEQDD was fabricated using mechanical components selected based on the design constraints or designed through mechanical analysis. Using a dynamometer, the efficiency map of the PEQDD was drawn. The control bandwidth comparison test with the motor originally used for HE showed improved bandwidth from 6.25 Hz to 20 Hz. Preliminary testing was done in walking and running conditions using an exosuit utilizing PEQDD. The test results showed that the actuator performance met all the design requirements.
Although previous research has improved the energy efficiency of humanoid robots to increase mobility, no study has considered the offset between hip joints to this end. Here, we optimized the offsets of hip joints in humanoid robots via the Taguchi method to maximize energy efficiency. During optimization, the offsets between hip joints were selected as control factors, and the sum of the root-mean-square power consumption from three actuated hip joints was set as the objective function. We analyzed the power consumption of a humanoid robot model implemented in physics simulation software. As the Taguchi method was originally devised for robust optimization, we selected turning, forward, backward, and sideways walking motions as noise factors. Through two optimization stages, we obtained near-optimal results for the humanoid hip joint offsets. We validated the results by comparing the root-mean-square (RMS) power consumption of the original and optimized humanoid models, finding that the RMS power consumption was reduced by more than 25% in the target motions. We explored the reason for the reduction of power consumption through bio-inspired analysis from human gait mechanics. As the distance between the left and right hip joints in the frontal plane became narrower, the amplitude of the sway motion of the upper body was reduced. We found that the reduced sway motion of the upper body of the optimized joint configuration was effective in improving energy efficiency, similar to the influence of the pathway of the body’s center of gravity (COG) on human walking efficiency.
High-collar shoes are a biomimetic approach to preventing lateral ankle injuries during high-demand activities; however, the influence of collar stiffness (CS) on parameters related to lateral ankle sprain prevention during running remains unclear. In this study, we investigated the effects of a custom-designed shoe CS on muscular activity, dynamic stability, and leg stiffness (Kleg) during running using a biomimetic design approach inspired by the mechanisms of ankle sprain prevention. Sixteen healthy male participants ran on a treadmill while wearing a custom-designed high-collar shoe with low, medium, and high CS conditions, measured using circumferential ankle pressure (CAP). Lower extremity kinematics and electromyography (EMG) data were recorded simultaneously. One-way repeated-measures ANOVA was conducted to compare the CS conditions. Results indicate that high and medium CS conditions significantly reduce sagittal and frontal ankle ranges of motion (ROMs) compared to the low CS condition, providing improved stability and support against lateral ankle sprain; moreover, there was a trend towards higher dynamic stability and Kleg with increasing CS. Our study highlights the importance of considering the CAP in regulating high-collar stiffness properties and how higher CS may provide better support for the ankle during running. Nevertheless, additional research is necessary to validate the efficacy of the current design in preventing ankle sprains during high-demand activities.
Soft wearable robots are attracting immense attention owing to their high usability and wearability. In particular, studies on soft exosuits have achieved remarkable progress. Walking is one of the most basic human actions in daily life. During walking, the ankle joint has considerable influence. Therefore, an exosuit design paradigm having a light and simple structure was developed with the goal of fabricating a soft exosuit that supports the ankle. The new exosuit matches the performance of existing exosuits while being as comfortable as everyday wear. A walking test through a combination with a mobile actuator system, which can maximize these advantages, was also conducted. The combination with the mobile system demonstrates the potential of using the new ankle exosuit as inner wear that maximizes the advantages of a lighter and simpler design. The exosuit design paradigm could serve as an effective guideline for manufacturing assistive exosuits for various body parts in the future.